twintex TFC8000 Series Operation Manual

Programmable ac power supply

Advertisement

Quick Links

Programmable AC Power Supply
TFC8000 Series
Operation Manual V1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TFC8000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for twintex TFC8000 Series

  • Page 1 Programmable AC Power Supply TFC8000 Series Operation Manual V1.0...
  • Page 2: Table Of Contents

    0 B S AFEFY INSTRUCTION............................II 1 B 1 . KEY POINTS TO INSTALLATION ......................- 1 - 6 B 1 .1 Unpacking and Examination ........................ - 1 - 7 B 1 .2 Preparation before Use .......................... - 1 - 8 B 1 .3 Storage and Shipping ..........................
  • Page 3 Use of Operation Manual Please read through and understand this Operation Manual before operating the product. After reading, always keep the manual nearby so that you may refer to it as needed. When mobbing the product to another location, be sure to bring the manual as well. Calibration notification We notify that the instruments included in this manual are in compliance with the features and specifications as stated in this manual.
  • Page 4: S Afefy Instruction

    S AFEFY INSTRUCTION This chapter contains important safety instructions that you must follow when operating the AC power supply and when keeping it in storage. Read the following before any operation to insure your safety and to keep the best condition for the instrument. Safety Symbols The following safety symbols may appear in this manual or on the instrument: Identifies conditions or practices that could result in injury or loss of...
  • Page 5: Key Points To Installation

    1 . KEY POINTS TO INSTALLATION This chapter introduces the rules of product unpacking, examination, preparation of pre-use and storage. 1 .1 Unpacking and Examination 1. Unpack the AC power supply and check the enclosed accessories. 2. The product is sealed in a packing case which is protected by pear brocade. If there are any damages with the packing case, please check the AC power supply and see if there is any deformation, scratch or panel damaged.
  • Page 6: .3 Storage And Shipping

    1 .3 Storage and Shipping Environment Location: The storage sites and transportation environment must be away from chemical deposition, explosive material, sulfuric acid mist or other substances which cause corrosion to metal. The installation site shall always keep lean and dry, and free from dusty, high humidity and vibration. Relative Humidity: <...
  • Page 7: Specifications

    2 . SPECIFICATIONS 2 .1 Serial Lineup and Features Main Features  Adopts Direct Digital Synthesis (DDS) technology, good waveform, high Performance stability frequency, good continuity  Adopts half sine wave current and similar DC component waveform test, high measuring accuracy ...
  • Page 8 2 .2 Specifications 1 0 B 1 Phase Output Linear Type 8000L 8001L 8002L 8003L 8004L 8005L Model 8000LG 8001LG 8002LG 8003LG 8004LG 8005LG Output capacity 500VA 1KVA 2KVA 3KVA 4KVA 5KVA Operation mode Linear amplification INPUT 1φ2W Phase Voltage 220V±10% Frequency 47Hz –...
  • Page 9 1 Phase Output Switching Type Model 8000 8001 8003 8005 8010 8015 8020 8030 8050 8100 8150 10KVA 15KVA 20KVA 30KVA 50KVA 100KV 150KV Power 500VA 1KVA 3KVA 5KVA Working SPWM INPUT 1φ2W 3φ4W Phase Voltage 220V±10% 380V±10% Frequency 47Hz - 63Hz OUTPUT 1φ2W Phase...
  • Page 10 3 Phase Output Switching Type 8006T 8009T 8012T 8015T 8020T 8030T 8060T 8100T 8150T 8300T 8450T Model 8006TG 8009TG 8012TG 8015TG 8020TG 8030TG 8060TG 8100TG 8150TG 8300TG 8450TG Power 6KVA 9KVA 12KVA 15KVA 20KVA 30KVA 60KVA 100KVA 150KVA 300KVA 450KVA Operation mode SPWM INPUT...
  • Page 11: Operation Instructions

    3 . OPERATION INSTRUCTIONS 3 .1 Front Panel Description 1 1 B Fig.3-1 Front panel for 1 Phase Linear Type Handler LCD display: for parameter setup and monitoring operation status Input keys Input switch 3 .2 Rear Panel Description 1 2 B Fig.3-2 Rear panel for 1 Phase Linear Type - 7 -...
  • Page 12: 3 B 3 .3 Operation Instructions

    Handler Cooling fan: temperature heat fan operation, please make sure of good ventilation RS232 interface: for PC control SYNC interface: output synchronization controlled signal (Positive inside, negative outside) Input/output connecting bar (L N G, L N G) Fuse holder with safe fuse inside AC output socket Cooling fan: temperature heat fan operation, please make sure of good ventilation 3 .3 Operation Instructions...
  • Page 13: 1 B 3 .3.3 Parameter Setup In Normal Mode

    2 1 B 3 .3.3 Parameter Setup in Normal Mode 1) Voltage Setup (Vset) In standby mode, press key “︿” or “﹀” to go to voltage setup. To input a new voltage value , dial the numeric key pad and press ENTER to confirm the new input. If there is wrong input, press key “←”...
  • Page 14 3) Output Key (ON) When all parameters are correctly set, press key ON, the unit will make output. 4) OFF/PAUSE Key To turn off the output, press key OFF/PAUSE. Press this key again; the output of the unit is paused. If there are problems in output, the unit will make the output as OFF, and the LCD will display “FAULT”...
  • Page 15: 2 B 3 .3.4 Parameter Setup In Programmable Mode

    2 2 B 3 .3.4 Parameter Setup in Programmable Mode 1) Data Group Setup (PG) In standby mode, press key “︿” or “﹀” to go to PG setup. To input a new value, dial the numeric key pad and press ENTER to confirm the new input. If there is wrong input, press key “←” to clear the wrong values and make new input.
  • Page 16: 3 B 3 .3.5 System Setup And Operation

    The frequency can be set at any value between 45Hz to 120Hz. If the optional range 40~500Hz is selected, the frequency can be set at any value between 40Hz to 500Hz. 4) Running Time Setup (TR) In standby mode, press key “︿” or “﹀” to go to running time setup. To input a new voltage value, dial the numeric key pad and press ENTER to confirm the new input.
  • Page 17 In AUTO range, when the voltage goes from low range to high range, or from high range to low range, the load will have an instant power off for 2-5 mS, which may have slight influence to some precise tests. When in HIGH range, there will be no such influence. 2) Angle Setup (ANGLE) (Available only in TFC8000L/8000LG Series) In standby mode, press key “︿”...
  • Page 18: 5 B 3 .5. Remote Control

    3 .5. Remote Control 1 5 B RS232 interface is a standard part for TFC8000 series. A GPIB interface is also provided as an optional part for users. The RS232 interface is the most commonly used interface for instruments. Its hardware is a D type 9-pin connector.
  • Page 19: Commands For Rs232/Gpib Interface

    3.6 Commands for RS232/GPIB Interface 1. A command with question mark”?” is to read the equipment. When the command is correctly executed, there is returned string. 2. A command without question mark “?” is to write to the equipment. When the command is correctly executed, there is no returned string.
  • Page 20: . Faults And Trouble Shooting

    PARWA_Command(cmd, respond); PARWA_Command("VSA 220.0", respond); // auto range 220V PARWA_Command("ON", respond); // running Sleep(200); sprintf(cmd, "?FR"); // read frequency if (PARWA_Command(cmd, respond)) Freq->Text = respond; if (PARWA_Command("?VO", respond)) Voltage->Text = respond; read voltage Sleep(20000); sprintf(cmd, "OFF"); // stop output PARWA_Command(cmd, respond); PARWA_Close();...
  • Page 21: Maitenance

    b) Test the signal wire between the instrument and the PC. The TXD to GND terminal should have a voltage of -8V to -12V. c) The receiving data may have problems, even if the remote control port works properly. This may be due to loose contact between the port and the cable connector. It can also be caused by jamming from the operating environment.