TimeLock™ Tab
Calculates the Analog in samples
as leading or lagging HD-1 Digital
Slide bar displaying
the TimeLock™ scale
in samples and Msec.
Slide bar – Scale that measures the Analog MPS to HD-1 Digital. The scrub marker will start
illuminate red when the correlation is below 70% and green above. The scrub marker will move
ahead and behind HD-1 depending on the diversity delay.
TimeLock™ Processing window – displays data for Audio Phase and TimeLock correlation.
Integer values are displayed in Samples and Msec. Positive indicates Analog is leading HD-1,
negative lags. Green indicates Correlation above 70% and Red below.
18  
M4.2Si TimeLock User Manual
Slide bar displaying Analog moving
against fixed HD-1 in real time. Green
indicates better than 70% correlation.
Figure 14.
Processing data window
indicates correlation, audio
phase, network time, and
TimeLock™ measured in
samples and Msec.