Wall mounted, fan assisted, room sealed, gas fired system boiler (32 pages)
Summary of Contents for Alpha Boilers Alpha CD24C
Page 1
Tel: (01322) 669443 Goldsel Road, Swanley, Kent BR8 8EX Fax: (01322) 615017 *HEJEID/=I Service Listed Alpha CD24C G.C. No. 47 532 19 Alpha CD24S G.C. No. 41 532 02 Alpha CD32C G.C. No. 47 532 21 For use with Natural Gas only Leave these instructions with the User Supplied By www.heating spares.co Tel.
The boilers will provide central heating (as required) during the 'on' times set on your clock (if fitted). Hot water is always available from the Alpha CD24C and CD32C boilers whenever a hot tap is opened and takes priority over the central heating.
BOILER CONTROLS 1. CENTRAL HEATING THERMOSTAT This thermostat controls the temperature of the water leaving the boiler for the heating system. For maximum output from the radiators the thermostat should be left at maximum i.e. fully clockwise. If lower heating temperatures are required, turn the thermostat anti-clockwise.
Service Engineer. BOILER OPERATION The operating sequence of the boiler is controlled by the selector switch on the control panel. In the case of the Alpha CD24C and CD32C, with the switch set to (hot water only) the boiler will only operate to provide domestic hot water, ideal for Summer use when central heating is not required.
USING A SHOWER - CD24C and CD32C Only Thermostatic or pressure equalising type - When using these types of shower set the boiler domestic hot water thermostat to maximum. The shower should then maintain a relatively constant temperature. Manual bath mixer type shower - When using this type of shower set the boiler domestic hot water thermostat to setting 7, This should avoid excessive temperatures at the shower.
GAS SAFETY REGULATIONS Current Gas Safety (Installation and Use) Regulations:- It is the law that all gas appliances are installed and serviced by a competent person, i.e. CORGI registered personnel. Failure to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance with the law.
Page 7
Is needle within or above the green band ? Turn selector to If not - See A Turn to (position 1) maximum Clock (if fitted) Alpha CD24C RESET and CD32C SELECTOR THERMOSTAT THERMOSTAT If this light is not on See B...