Alpha Boilers Alpha CD24C User Instructions

Range of wall mounted, fan assisted, room sealed, gas fired, high efficiency condensing boilers

Advertisement

Quick Links

Alpha CD24/32
Range of Wall Mounted, Fan Assisted, Room Sealed,
Gas Fired, High Efficiency Condensing Boilers
Leave these instructions with the User
Supplied By www.heating spares.co Tel. 0161 620 6677
User's
Instructions
For Technical help or for Service call ...
ALPHA HELPLINE
Tel: (01322) 669443
Goldsel Road,
Swanley, Kent BR8 8EX
Fax: (01322) 615017
*HEJEID/=I
Service Listed
Alpha CD24C
G.C. No. 47 532 19
Alpha CD24S
G.C. No. 41 532 02
Alpha CD32C
G.C. No. 47 532 21
For use with Natural Gas only

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Alpha CD24C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alpha Boilers Alpha CD24C

  • Page 1 Tel: (01322) 669443 Goldsel Road, Swanley, Kent BR8 8EX Fax: (01322) 615017 *HEJEID/=I Service Listed Alpha CD24C G.C. No. 47 532 19 Alpha CD24S G.C. No. 41 532 02 Alpha CD32C G.C. No. 47 532 21 For use with Natural Gas only Leave these instructions with the User Supplied By www.heating spares.co Tel.
  • Page 2: User Controls

    The boilers will provide central heating (as required) during the 'on' times set on your clock (if fitted). Hot water is always available from the Alpha CD24C and CD32C boilers whenever a hot tap is opened and takes priority over the central heating.
  • Page 3: Boiler Controls

    BOILER CONTROLS 1. CENTRAL HEATING THERMOSTAT This thermostat controls the temperature of the water leaving the boiler for the heating system. For maximum output from the radiators the thermostat should be left at maximum i.e. fully clockwise. If lower heating temperatures are required, turn the thermostat anti-clockwise.
  • Page 4: Lighting Instructions

    Service Engineer. BOILER OPERATION The operating sequence of the boiler is controlled by the selector switch on the control panel. In the case of the Alpha CD24C and CD32C, with the switch set to (hot water only) the boiler will only operate to provide domestic hot water, ideal for Summer use when central heating is not required.
  • Page 5: Important Notes

    USING A SHOWER - CD24C and CD32C Only Thermostatic or pressure equalising type - When using these types of shower set the boiler domestic hot water thermostat to maximum. The shower should then maintain a relatively constant temperature. Manual bath mixer type shower - When using this type of shower set the boiler domestic hot water thermostat to setting 7, This should avoid excessive temperatures at the shower.
  • Page 6: Gas Safety Regulations

    GAS SAFETY REGULATIONS Current Gas Safety (Installation and Use) Regulations:- It is the law that all gas appliances are installed and serviced by a competent person, i.e. CORGI registered personnel. Failure to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance with the law.
  • Page 7 Is needle within or above the green band ? Turn selector to If not - See A Turn to (position 1) maximum Clock (if fitted) Alpha CD24C RESET and CD32C SELECTOR THERMOSTAT THERMOSTAT If this light is not on See B...
  • Page 8 Alpha Therm Limited. These instructions have been carefully prepared but we reserve the right to Goldsel Road, Swanley, Kent BR8 8EX alter the specification at any time in the interest of product improvement. © Alpha Therm Limited 2003. Tel: (01322) 669443 Fax: (01322) 615017 email: info@alphatherm.co.uk website: www.alpha-boilers.com...

This manual is also suitable for:

Alpha cd24sAlpha cd32c