  • Page 1 Elite Suite ELT-KLCD EliteSuite LCD Keypad Installation Manual ELT-KLCD EliteSuite Installation Manual...
  • Page 2 PUBLICATION INFORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication Option Menu Navigation Updated Card Reader Interface Options Added Third Publication Slave Keypad Options Added Slave mode Zone Wiring Diagrams Added ELT-KLCD EliteSuite Installation Manual...
  • Page 3: Table Of Contents

    Reporting Options (Menu 2, 4) ................22 Panic Options (Menu 2, 5) ................. 25 ZONES (MENU 3) ...............27 Selecting a Zone ....................27 Zone Name ..................... 27 Zone Type....................... 27 Zone Options....................28 CONTACT ..................30 Contact......................30 ELT-KLCD EliteSuite Installation Manual...
  • Page 4: Introduction

    Hardware Compatibility This manual is written for hardware verison 208-4010-030 or higher and covers firmware application 1.22. This firmware communicates with a EliteSuite enabled Protégé System Controller firmware version 1.06 or above. ELT-KLCD EliteSuite Installation Manual...
  • Page 5: Wiring Configuration

    The condominium keypads are supplied with a wire loom attachment and are connected using a keyed 10 position snap lock connector. The 10 way wiring loom connection uses the following colour coding. Figure 2 - Wire Loom Colour Coding and Function ELT-KLCD EliteSuite Installation Manual...
  • Page 6: Communication Connection

    0V. Zone Input Wiring The EliteSuite LCD Keypad is capable of connecting to 4 zone inputs, each zone input can then be programmed to perform the required function in the system. ELT-KLCD EliteSuite Installation Manual...
  • Page 7 All resistors required to wire the zone configurations are provided with the EliteSuite LCD Keypad in the accessory bag. Figure 4 - 2 Zone Input (No Resistors) Figure 5 - 2 Zone Input (1K and 1K) ELT-KLCD EliteSuite Installation Manual...
  • Page 8: Fire Zone Input Wiring

    Fire zones that are installed in duplex mode operation are not recommended. Fire zones should ALWAYS be connected using the EOL resistor method (2R) as this provides both open and short circuit monitoring. ELT-KLCD EliteSuite Installation Manual...
  • Page 9: Slave Keypad Zone Wiring

    The choice between the two wiring options will be dependent on the physical configuration of the sensors and wiring in each installation. See General Options (Menu 2, 1) on page 16 for enabling duplex zones. Figure 8 - Slave Keypad Duplex Zone Wiring ELT-KLCD EliteSuite Installation Manual...
  • Page 10: Pgm (Programmable Output)

    Connect a relay or other interface device to this open collector output for activation of ancillary devices. The behaviour of this output can also be inverted in the programming, see the General Options section 0 for details on PGM programming. Figure 10 - LED Indicator Output ELT-KLCD EliteSuite Installation Manual...
  • Page 11: Slave Reader Network

    Figure 11 - Slave Reader Network Wiring To SAM Module For further information regarding wiring of the Reader device and the Stand Alone Modules, please refer to the PRX-SAM Stand Alone Module Installation Manual, provided with your SAM board or from www.integratedcontroltechnology.com. ELT-KLCD EliteSuite Installation Manual...
  • Page 12: Slave Keypad Network

    Note that the Slave Reader Network Enabled option must be OFF to allow use of the slave keypad network. Figure 12 – Slave Keypad Wiring to Master Keypad ELT-KLCD EliteSuite Installation Manual...
  • Page 13: Device Configuration

    1 to 250. Device Options [--------] The device options set options that relate to the mode of operation of the EliteSuite keypad. To toggle options press the keys [1] to [8] , ELT-KLCD EliteSuite Installation Manual...
  • Page 14: Display Contrast (Device Config Menu 3)

    Contrast [******* Use the left and right arrow keys to adjust the contrast (display will change as the contrast is adjusted) and press [ENTER] to save configuration. To exit without making changes press the [MENU] key. ELT-KLCD EliteSuite Installation Manual...
  • Page 15: Version Info (Device Config Menu 4)

    3, this will reset all programming to the default settings. Press [ENTER] to default keypad. Pressing the [ENTER] key will continue with the operation and default the keypad, pressing the [MENU] key will not default the keypad and return to the Offline Menu. ELT-KLCD EliteSuite Installation Manual...
  • Page 16: Local Installer Login

    Disarm the EliteSuite system before attempting to login with the installer code. recommended that installer modifications completed downloaded using Protege System Management Suite (PRT-SMGT). Ensure a module update command is executed when modifications are being made. ELT-KLCD EliteSuite Installation Manual...
  • Page 17: Timing (Menu 1)

    [RIGHT] or [LEFT] arrows will move the cursor to another digit. Alarm siren time: 004 mins Programming a siren time of 0 will result in the siren not being activated. ELT-KLCD EliteSuite Installation Manual...
  • Page 18: Reader Pre-Alarm Timer (Menu 1, 4)

    Reader Left Open time: 045 secs The minimum Left Open Time is 5 seconds, any number lower than 5 seconds entered will be automatically increased to 5 seconds to ensure correct reader operation. ELT-KLCD EliteSuite Installation Manual...
  • Page 19: Options (Menu 2)

    If Option 2 is set Option 1 does not have any function. When option 2 is set the zones will use a 1K and 2K4 resistor and provide monitoring for 2 zones. Enabled Duplex Zone Mode (4 Zones). Disabled Option 1 sets the zone configuration. ELT-KLCD EliteSuite Installation Manual...
  • Page 20 Reader Network Enabled: N Option 5 – Reader Slave Network Enabled the Slave Communications Port will be used to communicate with Card Reader Interfaces via a Standalone Module. ELT-KLCD EliteSuite Installation Manual...
  • Page 21 PGM Output Inverted: N Option 8 – PGM Output Inversion Enabled the PGM Output will follow the operation programmed by options 6 and 7, but the output will be opposite to the behaviour described in those functions. ELT-KLCD EliteSuite Installation Manual...
  • Page 22: Display Options (Menu 2, 2)

    Option 2 - Show 24HR Time Enabled the display will show the time in 24HR military format. Disabled the time will be shown in standard 12HR am/pm format. Option 3, 4, 5, 6, 7 and 8 - Reserved ELT-KLCD EliteSuite Installation Manual...
  • Page 23: Arming Options (Menu 2, 3)

    Disabled pressing the stay key during the stay exit delay will have no function. ELT-KLCD EliteSuite Installation Manual...
  • Page 24 Enabled the system can be FAST FORCE armed by pressing and holding the [FORCE] key. Disabled FAST FORCE arming is disabled. Option 5, 6, 7 and 8 - Reserved Reserved. Reserved. Do not modify the reserved options configuration. ELT-KLCD EliteSuite Installation Manual...
  • Page 25: Reporting Options (Menu 2, 4)

    Enabled the EliteSuite keypad will send a message when an alarm occurs on the EliteSuite system. This also enables the sending of the alarm silenced and alarm timed out messages. Disabled no message will be sent for an alarm event. ELT-KLCD EliteSuite Installation Manual...
  • Page 26 Access: N Option 5 - Report User Menu Access Enabled the system will report when the master user has accessed the main menu. Disabled no message will be sent when the master access's the main menu. ELT-KLCD EliteSuite Installation Manual...
  • Page 27 Disabled no message will be sent when the extended functions are triggered. Option 8 - Reserved Reserved. Reserved. It is recommended not to enable/disable or modify the settings of reserved options. ELT-KLCD EliteSuite Installation Manual...
  • Page 28: Panic Options (Menu 2, 5)

    Enabled the system will send a medical panic alarm to the front desk when the 4+6 keys are held for a period of 2 seconds. No message will be displayed on the screen or alarm generated. Disabled the 4+6 keys will not cause any alarm. ELT-KLCD EliteSuite Installation Manual...
  • Page 29 Disabled user code 8 will operate as a standard user. Option 5, 6, 7 and 8 - Reserved Reserved. Reserved. Do not modify the reserved options configuration. ELT-KLCD EliteSuite Installation Manual...
  • Page 30: Zones (Menu 3)

    To disable the zone and remove it from the ready display select the Disabled Option. To move to the next configuration screen press the [ENTER] key. To move the cursor press the [ ] and [ keys. ELT-KLCD EliteSuite Installation Manual...
  • Page 31: Zone Options

    [UP] or [DOWN] arrows to scroll through the available options. Zone Bypassing Enabled: Y Option 1 - Bypass Allowed Enabled the zone can be bypassed. A fire zone can never be bypassed regardless of the bypass setting. Disabled zone can not be bypassed. ELT-KLCD EliteSuite Installation Manual...
  • Page 32 Disabled the zone is not able to be force armed. Option 4, 5, 6, 7 and 8 - Reserved Reserved. Reserved. It is recommended not to enable/disable or modify the settings of reserved options. ELT-KLCD EliteSuite Installation Manual...
  • Page 33: Contact

    Integrated Control Technology welcomes all feedback. Please go to our website or use the information below. Integrated Control Technology P.O. Box 302-340 Unit C North Harbour Post Centre 6 Ascension Place Auckland Mairangi Bay New Zealand Auckland New Zealand Phone: +64-9-476-7124 Fax: +64-9-476-7128 www.integratedcontroltechnology.com ELT-KLCD EliteSuite Installation Manual...