GROUNdING
INSTRUCTIONS
This stove is for use on 120 volts. The cord has a
plug as shown in Figure 2. An adapter is available
for connecting three-blade grounding-type plugs
to two-slot receptacles. The green grounding lug
extending from the adapter must be connected to
a permanent ground such as a properly grounded
outlet box. The adapter should not be used if a
three-slot grounded receptacle is available.
Grounding Pin
Figure 2 - Grounding Methods
OPERATING
INSTRUCTIONS
Once the unit has been properly connected to a
ground electrical outlet, it is ready to operate.
Note: Ensure the circuit breakers for power
supply are turned on.
CONTROl PANel OPeRATION
Controls are located on the back of the unit near
the top (see Figure 3).
1. Main ON/OFF power switch: This switch
is located at the furthest right corner on the
control panel when looking at the back of
the unit. Turn the switch to ON and unit
will be ready to operate. The "|" indicates
ON and "O" indicates OFF.
2. Flame ON/OFF Switch: This switch is
located in the middle between the Main
ON/OFF switch and the Heater ON/OFF
switch on the control panel when looking at
the back of the unit. Turn the switch to ON
and the flame effect will turn on. The "|"
indicates ON and the "O" indicates OFF.
3. Heater ON/OFF Switch: This switch is
located to the left of the Flame ON/OFF
switch on the control panel. It has a symbol
of the sun directly below it.
4. Thermostat Control Dial: This dial is
located at the furthest left corner on the
control panel. It has a symbol of a ther-
mostat directly below it. Turn the dial
clockwise past the number 8. You should
hear a small clicking sound indicating
4
the heater has started and heat will emit
from the vents at the top of the unit from
the front. To turn off heater, turn the dial
counter clockwise past number 1 and turn
the Heater Switch to OFF position. To
increase the desired temperature, turn the
dial clockwise towards Number 9.
Figure 3 - Electric Stove Control Panel
Adapter
nect power and allow the heater to
cool before performing any clean-
ing, maintenance or relocation of
this heater. Turn controls to OFF
and remove plug from outlet or
turn off circuit breaker to heater.
Turn off heater and circuit breaker to heater before
performing any cleaning and/or maintenance. Al-
low heater to cool completely.
CleANING FRONT PANel GlASS
unit, the power supply should
be disconnected and the unit
should be cool.
Over time the front glass panel may become dirty or
dusty. Dust can be removed by lightly rubbing the
glass surface with a clean, lint free cloth or paper
towel. To remove fingerprints or other marks, use a
cloth dampened with a good quality household glass
cleaner. The front glass panel should be completely
dried with a clean, lint free cloth or paper towel.
sive cleaners on glass panel. Do
not spray liquids directly onto
any surface of the unit.
www.desatech.com
Flame Switch
Built-In
Thermostat
CLEANING ANd
MAINTENANCE
WARNING: Always discon-
WARNING: When cleaning
CAUTION: Do not use abra-
Main Power
Switch
Heater Switch
119732-01A