Genie Signal Electrical Details

Power Supply (pin 2): +12V DC nominal at 0.5 Amp minimum.
(see Camera Performance Specifications)
Over voltage and reverse voltage protection circuit built in. The protection circuit is reset by shutting down or
disconnecting the power supply.
The 12-pin Hirose male connector shell and cable shield should connect to the supply earth ground to improve
EMI and ESD shielding.

External Inputs

Opto-coupled (2V to 12V, 2mA minimum) with internal current limit.
RS422 or TTL signal type (see figures below).
24 Volt signals supported with additional external current limiting (see figure below).
Used as trigger or integration control.
External signal polarity selected via configuration parameter.
User programmable debounce time from 1 to 255µs.
See "Input Controls via Sapera LT or GigE Vision Compliant
The opto-coupler is typically a Fairchild HMHA281 with the following characteristics.
Input Electrical Parameter Description
Voltage threshold to turn OFF
Voltage threshold to turn ON
Minimum input current to turn ON
Maximum input current
Minimum input pulse width to turn ON
Output rise time (typical)
Output fall time (typical)
Maximum input voltage
Maximum reverse voltage
Genie Monochrome Series-GigE Vision Camera
Applications" on page
56.
Value
0.8 V
2 V
2 mA
50 mA
30 µs
10 µs
50 µs
13 V
- 6 V