User Manual of D1 Series Net DVR D1 Series Net DVR User Manual (V1.0) -Full Manual Thank you for purchasing our embedded Net DVR. This manual is applicable for SATA and D1 SATA series Net DVR. Please read this User Manual carefully to ensure that you can use the device correctly and safely.
User Manual of D1 Series Net DVR Index Version Description...........................4 Chapter1 Product Introduction....................6 Summary ........................6 Features ........................6 Chapter2 Installation.........................9 Checking the DVR and Its Accessories..............9 HDD Installation .......................9 Rear Panel Description....................10 2.3.1 4-ch 4 D1 Rear Panel..................10 2.3.2 4-ch SATA Rear Panel..................11 2.3.3...
Page 3
User Manual of D1 Series Net DVR View Tampering Alarm ...................60 Video Loss Alarm....................62 6.10 Motion Detection Alarm ..................64 6.11 Preview Properties ....................67 6.12 Recording Setup ......................69 6.13 External Alarm Input and Relay Output..............72 6.14 Network Parameters ....................77 6.15 PTZ .........................78 6.16...
User Manual of D1 Series Net DVR Version Description Version2.0 built 070206: The new version firmware DVR has the following new features: 1. Support USB mouse Recommended USB mouse model list: Logitech: M-UV83 Benq: M800 ViewSonic: MC204 Philips: SPM4500BB/93 LG: LGIM-ML208 GlodFly: GF-OP718 Newmen: MS0270 (www.newmen.com.cn)
Page 5
User Manual of D1 Series Net DVR If you select “Backup” mode, in DVR “Playback” menu, you can select SATA HDD for backup. 5.Solved old version some bugs VGA black screen and Aux audio output issues Page Total...
TCP/IP. The firmware is burned in the flash, more stable and reliable. D1 series device has both the features of digital video recorder (DVR) and digital video server (DVS). It can work stand alone, also be used to build a powerful surveillance network, widely used in bank, telecommunication, transportation, factories, warehouse, irrigation, etc.
Page 7
User Manual of D1 Series Net DVR Preview and playback Support BNC analog moniotor and VGA output for main output Support one aux video and audio input Support multiple preview modes. Support sensitive area mask. Support camera spiteful block alarm.
Page 8
User Manual of D1 Series Net DVR Provide network SDK. Provide client demo source code. Page Total...
User Manual of D1 Series Net DVR Chapter2 Installation Warning: Before you install the DVR, please make sure the power of DVR is switched off. Checking the DVR and Its Accessories When you get the product, check that all the items are included in your product package.
User Manual of D1 Series Net DVR Rear Panel Description Notice: Please refer to real product for different model. 2.3.1 4-ch D1 Rear Panel ESATA ALAR M O U T LI N E I N VO U T VAU X...
User Manual of D1 Series Net DVR External Alarm Input 4 sensor alarm in. Relay Output 2 replay output. Ground 100~240VAC AC Input Optional. Extend 1 internal SATA to E-SATA. E-SATA 2.3.2 4-ch SATA Rear Panel Index Physical Interface Description Video Input Standard BNC.
User Manual of D1 Series Net DVR RS-485 PTZ connection. Using T+/T- to connect PTZ. External Alarm Input 4 sensor alarm in. Relay Output 2 replay output. Ground 100~240VAC AC Input Optional. Extend 1 internal SATA to E-SATA. E-SATA 2.3.3 8-ch/16-ch D1 Rear Panel...
Page 13
User Manual of D1 Series Net DVR Main video output Main monitor for video and menu. Main audio output Main monitor for audio preview and playback. Line In Audio line input for voice talk. VGA Interface VGA display. Connect RS-232 devices. Refer to Appendix B for pin RS-232 definition.
User Manual of D1 Series Net DVR External Alarm In/Out Connection Alarm input port (drp node): G (GND): Conenct the GND of sensor. 1~8: Alarm input, support normal open/normal close. 0: Reserved. Alarm output: 1G~4G: 4 relay output. Alarm output connection...
User Manual of D1 Series Net DVR Chapter3 Operational Instructions Front Panel This picture is the front panel of D1 series Net DVR. Feature Name Description DVD-RW Access the DVD-RW drive by gently pressing on the access door READY: DVR is ready for use...
Page 16
User Manual of D1 Series Net DVR ESC: Cancels action / returns to previous screen EDIT: -During character field edits, this deletes the current character -Selects or × to enable/disable options -Edits character and numeric fields within the menu PLAY:...
User Manual of D1 Series Net DVR IR receiver for IR remote controller Power switch with indicator lamp. Green indicates power on, red indicates power off, no Power lamp indicates no power is being supplied. IR Controller Index Name Description POWER Turnoff device.
Page 18
User Manual of D1 Series Net DVR Same as [Main/Aux] key of frint VOIP panel. MENU Same as MENU key of front panel. PREV Same as PREV key of front panel. Direction Keys Same as direction keys and enter key ENTER of front panel.
User Manual of D1 Series Net DVR Menu Description 3.3.1 Menu Items Menu Name Function Menu Name Function Camera name and position setup Video standard Adjust Brightness, Contrast, Hue Brightness and Saturation Menu transparency OSD Display mode, position and Unit name...
User Manual of D1 Series Net DVR Restore parameters Upgrade firmware Text input mode HDD management ATM IP address Clear alarm output Transaction Utilities ATM type Reboot Text information Power off View log System information 3.3.2 Menu Operation How to enter into menu mode Press【MENU】key to enter into DVR main menu.
Page 21
User Manual of D1 Series Net DVR Each menu contains different kinds of items. There is a small rectangular frame named “Active Frame” which is pointing to the selected item. This “Active Frame” can be moved by 【 】or【 】keys. There are such kinds of menu items: Check Box: Provide 2 options, “...
Page 22
User Manual of D1 Series Net DVR Press【PREV】key to exit menu and return to preview mode. Page Total...
User Manual of D1 Series Net DVR Character Input In the menu interface, if you enter into edit status (for example, in the “camera name” edit box), at the bottom of screen, the input status is appeared: Here it means you can press numeric keys to input digital number.
User Manual of D1 Series Net DVR Chapter4 Basic Operation Guide Power on Note: Please make sure the power supply matches DVR and AC cable connected correctly. Before switch DVR on, please connect one monitor with VOUT or VGA interface. Otherwise, you can not see graphic user interface and can not operate.
Page 25
User Manual of D1 Series Net DVR Press【A】key to display or hide the camera status bar. Camera record status is following: Icon Icon Color Status Description White No video signal Yellow Vdieo input Pink Manual recording Green Real time recording...
Page 26
User Manual of D1 Series Net DVR Camera alarm status is following: Icon Icon Color Status Description White Video signal lost Yellow View tampering alarm Pink Motion&External alarm Green No alarm Blue Motion alarm External alarm Press numeric keys to switch over individual camera preview. If DVR has less than 10 channels, press one numeric key to switch corresponding channel.
User Manual of D1 Series Net DVR User name and password Note: When DVR is delivered from factory, there is only one default administrator named “admin”, and password is “12345”. The administrator’s name can not be modified, while the password can be modified.
Page 28
User Manual of D1 Series Net DVR Setp 2: Enter into password modification menu Move the “Active Frame” to “Password” icon by using【 】/【 】keys. Press【ENTER】key to enter into following password menu: Step 3: Input new password Press 【 EDIT】 key to enter into edit box. You can use numeric keys to input new password. The password can be null.
User Manual of D1 Series Net DVR PTZ Control Note: The user must have the “PTZ control” right. PTZ control interface In preview mode, press【PTZ】key, in the login dialog, select one user name and input the correct password, you can enter into PTZ control interface.
Page 30
User Manual of D1 Series Net DVR 【FOCUS+】,【FOCUS-】; FOCUS control keys: 【IRIS+】,【IRIS-】; IRIS control keys: 【REC/SHOT】; Adjust preset keys: 【PLAY/AUTO】; Auto control key: 【WIPER/MENU】; Wiper control key: 【LIGHT/F1】; Light control key: Auxiliary device control key:【AUX/F2】 Adjust preset description In PTZ control mode, press【REC/SHOT】key, and press the preset number (three numeric keys), DVR will adjust the corresponding preset number.
User Manual of D1 Series Net DVR Manual Record Note: The user must have the corresponding right, DVR has HDD and HDD is formatted already. Manual record In preview mode, press【REC】key, in the pop-up login dialog, select the name and input the correct password, you can enter into the “Manual Record”...
User Manual of D1 Series Net DVR Playback Note: The user must have “Playback” right. Playback interface In preview mode, press 【PLAY】 key, in the pop-up login dialog, select username and input correct password, you can enter into “Playback” interface.
Page 33
User Manual of D1 Series Net DVR Main Channel: Use【↑】or【↓】key to select one channel. Second: If DVR support 2-ch playback, you can use 【↑】 or【↓】key to select the second channel except the main channel. These two channels can be playback synchronously. If you select the second channel as none, only the main channel is playback.
Page 34
User Manual of D1 Series Net DVR palyback), record type, time section. Move “Active Frame” to “Search” button and press 【 ENTER】 key, DVR will search and list the matched files. If the matched files are more than 8, you can use “Page No.” to select page (use numeric keys or【↑】 【↓】...
Page 35
User Manual of D1 Series Net DVR One Channel Playback Two Channels Playback At the bottom of image, there is an information bar and the following information is included: Volume, Play Progress, Play Speed, Played Time and File Total Time.
Page 36
User Manual of D1 Series Net DVR 【ENTER】to paly one frame. Copy segment:【EDIT】 Exit: 【ESC】 Playback switch: When in 2-ch playback, press【PREV】to switch between main channel and second channel. Note: When DVR is busy, if you select high play speed, maybe there is difference for actual play speed.
User Manual of D1 Series Net DVR Backup Recorded Files Note: The user must have “Playback” right. Please connect with backup devices before you start to backup. In the playback interface, you can backup the recorded files. In the preview mode, press 【PLAY】 key, in the login dialog, select username and input the correct password, you can enter into the playback interface.
Page 38
User Manual of D1 Series Net DVR Step 2: Select the files that you want to backup In the file list box, use【↑】or【↓】keys to move the scroll bar. When the scroll bar stays at the file you wan to backup, press【EDIT】key to select it. The symbol “ ” is the selection tag. You can use the same method to select other files you want to backup.
User Manual of D1 Series Net DVR Playback the video segment You can use our file player software to playback the video segment in PC. You can find the player software in attached CD. Exit playback interface Please refer to chapter 4.6.
Page 40
User Manual of D1 Series Net DVR Note: When message of “Shut down…” is appeared, please do not press 【 POWER】 key any more, otherwise, DVR can not be shut down. Shut down DVR abnormally Use the power switch of real panel When DVR is run, if you switch off the power, the HDD in DVR will be damaged.
Chapter5 Main and Aux Output Function Main and aux output 16 SATA, 8-D1 and 16-D1 series DVR has both one main output and one aux output. You can use main video output to enter into DVR menu as following, while aux output can not display DVR menu.
User Manual of D1 Series Net DVR Main and Aux output preview You can use “Main” output to enter into DVR menu, setup both “Main” and “Aux” output preview properties. Please press 【Mian/Aux】 button to enter into “Main” output control mode, then press 【Menu】 button to enter into DVR menu, the main video output will display the following DVR menu: Move “Active Frame”...
Page 43
User Manual of D1 Series Net DVR Preview mode: For preview mode item, you can use【↑】 【↓】key to select one mode. If DVR has only 1 channel, you can select only “1 Screen” option. If DVR has 4 channels, there are “1 Screen” and “4 Screen”...
Page 44
User Manual of D1 Series Net DVR After you define the camera preview order, you can select preview mode to meet your demand. Save setup: Press “Confirm” button to save preview configuration. Press “Cancel” or 【ESC】key to abort. Whether in “Main” or “Aux” output control mode, you can press 【PREV】button to enter into live preview and change preview screen mode.
User Manual of D1 Series Net DVR Main and Aux output playback Both “Main” and “Aux” output can be used to playback the recorded files on DVR HDD. Press 【Main/Aux】button to enter into “Main” or “Aux” control mode, and press 【PLAY】button to enter into “Playback”...
User Manual of D1 Series Net DVR Main or Aux output to control PTZ You can press 【Main/Aux】 button to enter into “Main” or “Aux” output control mode and press 【PTZ】 button to control one PTZ. Please refer to “User Manual of Embedded Net DVR” for PTZ control information.
User Manual of D1 Series Net DVR Chapter6 Parameters Setup Guide Only the users that have “Parameters Setup” right need read this chapter. When the following parameters are modified and saved, you must reboot the DVR to make the new parameters take into effective. Other parameters do not need to reboot.
Page 48
User Manual of D1 Series Net DVR In the user name list box, only “admin” is existed. You can use【→】key, move “Active Frame” to password edit box, and press【EDIT】key to enter into edit status. Press numeric keys to input the new password. The password is only combined by 16 numerals at most.
User Manual of D1 Series Net DVR Add and Delete User Enter into “User Management” interface. Add user The steps are following: Step 1: Enter into “User Management” menu Please refer to chapter 5.1 Step 2: Add new user name In the “User Management”...
Page 50
User Manual of D1 Series Net DVR In the users list box of “User Management” menu, use【 】 【 】keys to select the new user name, then use 【 】key to the password edit box. Press【EDIT】key to enter into edit box, use numeric keys to input the new password.
Page 51
User Manual of D1 Series Net DVR Local rights are for local operation, such as the operation using front panel, IR controller and RS-485 keyboard. PTZ control: Locally control PTZ; Record: Manual start/stop recording; Playback: Local playback and backup the recorded files;...
User Manual of D1 Series Net DVR Unit Name and Device ID Unit name In the “Display” menu: There is an item named “Unit Name”. The default unit name is “Embedded Net DVR”. Move “Active Frame” to unit name edit box, press【EDIT】key to enter into edit status, you can modify the unit name. About how to input characters, please refer to chapter 3.4.
User Manual of D1 Series Net DVR Video Output Standard and VGA Setup Video output standard There is one VOUT BNC connector at the rear panel of DVR. It is used to connect with analog monitor and can support PAL or NTSC video output. You can modify video output standard to match video input.
User Manual of D1 Series Net DVR OSD Setup OSD is abbreviation of “On Screen Display”. For our embedded DVRDVS, it includes displaying system time and camera name. OSD settings include: System time, time format, time display position, camera name, camera name display position, etc.
Page 55
User Manual of D1 Series Net DVR Transparent&Flashing, Opaque&Flashing, Move “Active Frame” to “OSD” item, you can select one mode. Display position and format: Move “Active Frame” to “Position” button on the right side of “OSD”, press 【ENTER】to enter into setup image, you can find there are 22*18 (for NTSC, 22*15) small panes, and OSD position is in red.
Page 56
User Manual of D1 Series Net DVR Step 1: Select one camera. Step 2: Move “Active Frame” to camera name edit box, press【EDIT】key to enter into edit status, you can input digital number, uppercase and lowercase characters (refer to Chapter 3.4). The camera name can support 32 characters.
User Manual of D1 Series Net DVR Video Parameters Setup For different camera and different background, in order to get the best video image, you need to adjust video parameters such as brightenss, saturation, contrast and hue, etc. You can setup the camera individually, and also you can copy the video parameters of one camera to any other cameras.
User Manual of D1 Series Net DVR Mask Area Setup In some cases, maybe you want mask the sensitive area. This area will not be preview and recorded. The mask area setup steps are following: Step 1: Enter into “Image Setup” menu: Step 2: Select one camera: You can use【...
Page 59
User Manual of D1 Series Net DVR side. For PAL camera, the whole screen is divided into 22*18 panes (22*15 for NTSC), you can use 【↑】 【↓】 【→】 【←】keys to move the yellow pane to your hope position and press【EDIT】key, the yellow pane will be turned into red, then you can use【↑】...
User Manual of D1 Series Net DVR View Tampering Alarm If you enable this function, when someone blocks the camera spitefully, DVR will make warning alarm. Step 1: Enter into “Image Setup” memu: Step 2: Select camera: Please use【 】 【 】keys to select one camera.
Page 61
User Manual of D1 Series Net DVR Step 6: Alarm schedule setup: When there is view tampering alarm happened, DVR will handle the alarm based on the schedule. You can set 4 periods for each day one week. Also you can copy the schedule of one day to other days.
User Manual of D1 Series Net DVR Video Loss Alarm When the video cable or camera has something wrong, the video image is lost. If you enable video loss alarm, in such case, DVR will make alarm. Step 1: Enter into “Image Setup” menu: Step 2: Select camera: Use【...
Page 63
User Manual of D1 Series Net DVR Note: The 4 time periods can not be repeated. Please reboot DVR to make parameters into effective. Step 5: Setup alarm policy: You can select one or more response solutions, including “On Screen Warning”, “Audible Warning”, “Upload to Center”...
User Manual of D1 Series Net DVR 6.10 Motion Detection Alarm If you enable this function, when there is motion detected, DVR will make alarm. Step 1: Enter into “Image Setup” menu: Step 2: Select camera: Use【 】 【 】key to select one camera.
Page 65
User Manual of D1 Series Net DVR The whole screen is divided into 22*18 panes (NTSC: 22*15). There is one yellow panel on the upper left side. The motion area setup steps are the same as that of mask area setup (refer to chapter 5.7). The only differences are that you can use【PTZ】key to set the whole screen as motion area, and mutil motion areas can be...
Page 66
User Manual of D1 Series Net DVR 【↓】: Down enlarge red pane; 【↑】: Up shrink red pane; 【PTZ】: Set whole screen as motion area; 【A】: Clear all motion areas; 【ENTER】: Save and return “Image Setup” menu; 【ESC】: Cancel setup and return “Image Setup” menu;...
User Manual of D1 Series Net DVR use【ENTER】or【EDIT】key to enable the flag into “ ”. Note: In order to make the cameras start recording, in “Recording” menu, you must enable recording schedule and set “Rec Type” as “Motion Detection” or “Motion | Alarm”. Please refer to chapter 5.12 for recording setup.
Page 68
User Manual of D1 Series Net DVR Step 2: Preview properties: Preview mode: For preview mode item, you can use【↑】 【↓】key to select one mode. If DVR has only 1 channel, you can select only “1 Screen” option. If DVR has 4 channels, there are “1 Screen” and “4 Screen”...
User Manual of D1 Series Net DVR 6.12 Recording Setup In main menu, there is an icon named “Recording”. You can enter into recording menu as following: “Recording” menu description: If HD Full: There are two options: “Overwrite” and “Stop recording”. If you select “Overwrite” option, when all HDDs in DVR are full, DVR will overwrite the earliest recorded files and continue recording.
Page 70
User Manual of D1 Series Net DVR “Max Bit Rate” option. In this case, we can calculate the recorded file size and network bandwidth that we need. Max Bit Rate: If you select variable bit rate, when the video input has great movement, we need to limit the max bit rate.
Page 71
User Manual of D1 Series Net DVR Step 2: Select ond day and enable all day recording option For “Day” item, there are options: Monday, Tuesday, Wednesday, Thursday, Friday, Saturday and Sunday. Use【↑】 【↓】keys to select one day. Move “Active Frame” to the check box on the right side of “All Day” item, press【ENTER】or【EDIT】key to enable “All Day”...
User Manual of D1 Series Net DVR Step 2: Select ond day and disable all day recording option For “Day” item, there are options: Monday, Tuesday, Wednesday, Thursday, Friday, Saturday and Sunday. Use【↑】 【↓】keys to select one day. Move “Active Frame” to the check box on the right side of “All Day” item, press【ENTER】or【EDIT】key to disable “All Day”...
Page 73
User Manual of D1 Series Net DVR external alarm input and 4 relay output. In “Alarms” menu, you can setup for each external alarm input. In main menu, move “Active Frame” to “Alarms” icon and press【ENTER】key to enter into alarms menu: External alarm input setup: Step 1: Select one alarm input Use【↑】...
Page 74
User Manual of D1 Series Net DVR You can select channels to record for each alarm input. In the sub menu, you can use【ENTER】or【EDIT】 key to enable record channel. “×” means disable and “ means enable. Note: In order to trigger the channel to record, in “Recording” menu, you must enable recording and select record type as “Alarm”...
Page 75
User Manual of D1 Series Net DVR Cruise: Set the flag as “ ” to enable cruise. Please refer to chapter 5.15 for cruise setup. Press “Confirm” button to save and return “Alarms” menu. Press “Cancel” button or 【 ESC】 key to abort and return “Alamrs”...
Page 76
User Manual of D1 Series Net DVR setup, press “Confirm” button to return “Alarms” menu. Step 5: Copy one alarm output parameters to other alarm output In “Alarms” menu, you can copy parameters of current alarm output to other alarm output.
User Manual of D1 Series Net DVR 6.14 Network Parameters If you want use network to access DVR, you must setup network parameters. Note: If any network parameter is modified, you must save and reboot DVR to make it into effective.
User Manual of D1 Series Net DVR Multicast IP: It is one D-class IP address, among 224.0.0.0 --- 239.255.255.255. If you do not use multicast function, you do not need to set. Some routers will prohibit multicast function in case of network storm.
Page 79
User Manual of D1 Series Net DVR enter into PTZ menu as following: PTZ menu description Select channel: Select one PTZ camera. RS-485 parameters: Including baudrate, data bit, stop bit, parity, flow control, etc. These parameters must be the same as those of PTZ. Protocol.
Page 80
User Manual of D1 Series Net DVR Cruise setup: Cruise is remembering the track of PTZ movement. Please make sure the PTZ you are using can support cruise function. Preset setup In “PTZ” menu, move “Active Frame” to “Setup” button on the right side of “Preset” item, press 【ENTER】 , you can enter into “Preset”...
Page 81
User Manual of D1 Series Net DVR In “Sequence” setup menu, first input the sequence number. The sequence is among 1 --- 16. Each sequence is made up of cruise points, and each cruise point includes preset number, dwell time and dwell speed. Dwell time is the time staying at that preset number.
Page 82
User Manual of D1 Series Net DVR Press “RecCru” button, you will enter into “PTZ control” interface. You can start controlling PTZ with direction keys, press【ENTER】to save the operation track and return “Cruise” setup menu. Press “StartCru” button to repeat the PTZ track until you press “Stop” button.
User Manual of D1 Series Net DVR 6.16 RS232 setup There is one RS-232 port at DVR rear panel. In main menu, move “Active Frame” to “RS232” icon and perss【ENTER】key, you enter into “RS232” setup menu: RS232 menu description RS-232 parameters: Including baud rate, data bit, stop bit, parity, flow control, etc.
Page 84
User Manual of D1 Series Net DVR remote PC dialup through PSTN. Phone: Only used when work mode is “PPP” and PPP mode is “Active”. It is the phone number of remote Callback and Data Encryption: Only used when work mode is “PPP”. They are not available.
Page 85
User Manual of D1 Series Net DVR Step 3: Save setup In “Recording” menu, press “Confirm” button to save parameters. Step 4: Setup Modem used on DVR side Use DCE calbe to connect Modem with PC serial port. You can use HyperTerminal or NetTerm to setup modem: AT&F ---- Retore default parameters (Generally, Modem is hard flow control)
Page 86
User Manual of D1 Series Net DVR Page Total...
Page 87
User Manual of D1 Series Net DVR Step 3: Establish the dialup connection Select the Modem connected with PC just like the dialup network connection, input the telephone number connected with DVR’s modem. Input the username, password. They must be the same as that DVR PPP setup.
User Manual of D1 Series Net DVR 6.17 Exceptions The exceptions can be handled at present include: hard disk full, hard disk error, illegal access, IP address conflict, network failure, and NTSC/PAL differ. Enter into “Exceptions” menu: Including the following handle methods: Audible Warning: DVR beep warning.
User Manual of D1 Series Net DVR 6.18 Transaction Information The DVR can actively obtain or passively receive the credit card number from ATM machine linked through network or serial port, and credit card number can be overlay on live video, recorded and playback. The following description indicates how to carry out relevant parameter setting according to different links to ATM machine.
Page 90
User Manual of D1 Series Net DVR When the ATM machine is sending transaction information to bank center, DVR will capture the data package through network, and analyse the data according to the format. Then DVR will overlay the correspond text on live video.
Page 91
User Manual of D1 Series Net DVR In the case, you must set the RS-232 of DVR as transparent channel mode as following: A software must be run in the ATM machine, and send the credit card number, transaction code to DVR through RS-232 port.
Page 92
User Manual of D1 Series Net DVR In the case, you must set the RS-232 of DVR as transparent channel mode as following: Also, a software must be run in ATM machine, and send command to DVR through RS-232 port based on communication protocol.
User Manual of D1 Series Net DVR Chapter7 Utilities There are many tools in “Utilities” menu. Including “SavePara”, “RestorePara”, “Upgrade”, “Hard Disk”, “Stop Alarm Out”, “Reboot”, “Power Off”, “View Log” and “System Info”. Enter into “Utilities” menu: Save Parameters Save factory default parameters into FLASH memory. You can reboot DVR to make them into effective.
User Manual of D1 Series Net DVR Upgrade You can use this function to upgrade the firmware. Please confirm the language is matched. Press “Upgrade” icon, in the pop-up dialog, you can select either “FTP” or “USB” upgrade mode. If you select “FTP” mode, you will enter into “FTP Upgrade” menu: Input the ftp server IP and press【ENTER】key.
User Manual of D1 Series Net DVR Hard Disk Management Check HDD work status Capacity, Free space, Stand by or not, Normal status or not. Format HDD Before formatting stop all recording. After formatting, you must reboot DVR, otherwise DVR will not work normally.
Page 96
User Manual of D1 Series Net DVR If you want to view the log based on default option, just press【ENTER】key. DVR will list all matched information. Also you can select options to search (By Type, By Date, By Type&Date). By Type To view log information of the assigned type.
Page 97
User Manual of D1 Series Net DVR Type, Channel No, HDD No, Alarm In and Alarm Out. You can press “More Info” button for more information, also slect page number to view more information. Step 5: Press “Return” button back to “Utilities” menu.
User Manual of D1 Series Net DVR Chapter8 Firmware Upgrade The DVR firmware is stored in FLASH ROM. You can use DVR upgrade function to write the firmware file (digicap) into FLASH. There are two cases that you need to upgrade DVR firmware. One is update old firmware. The other is when the code in DVR FLASH is crashed.
Page 100
User Manual of D1 Series Net DVR Select “Users/rights” under “Security” menu item. The following dialog box will be pop-up. Create new user. Click “new user’. New user dialog pops up. Input user name “target”. Click “OK”. In the password dialog, input password “target” in “New Password” and “Verify Password” edit box.
Page 101
User Manual of D1 Series Net DVR 7. Next time, you need not setup again, just double click and open “wftpd32.exe” to upgrade the DVR/DVS firmware. Page Total...
User Manual of D1 Series Net DVR Upgrade Mode Use client software to upgrade the firmware file. You do not need to use ftp server software. Please refer to the client software user manual for detail information. Use “FTP” function of “Upgrade” sub menu in “Utilities” menu. You need one host PC to run FTP server software and place firmware file (digicap), and make sure DVR and PC are in the same sub net.
User Manual of D1 Series Net DVR Appendix A HDD Capacity Calculation Calculate total capacity needed by each DVR according to video recording (video recording type and video file storage time). Step 1: According to Formula (1) to calculate storage capacity that is the capacity of each channel needed for every hour, unit Mbyte.
User Manual of D1 Series Net DVR Appendix B DVR Connect Cable Definition 1 RS-485 connect cable made method Material and tool One twist cable (8 pins), one standard RJ45 connector and one tool special for RJ45. RJ45 introduction Pin definition To make the connect cable according the follows.
User Manual of D1 Series Net DVR The corresponding relationship of the direct cable (2) Use the following method to make the cross network cable when DVR is directly connected with client-end PC. The corresponding relationship of cross cable 3 RS-232 connect cable made method...
Page 106
User Manual of D1 Series Net DVR Pin index Name Description Carrier Detect Receive Data Transfer Data Clear Data Request to Send Terminal Device Ready Ground Null — — According to demand, the following three situations are considered to make the serial port plug-in according to the corresponding relationship of the pin definition.
Page 107
User Manual of D1 Series Net DVR Connection for RJ45 and DB9 25-pin to 9-pin converter internal connection is defined as following: Connection for DB25 and DB9 (3) When the serial port of DVR is connected with DCE device (like MODEM), one end of the cable is...
User Manual of D1 Series Net DVR Appendix C Specifications D1 SATA Video compression H.264 Preview resolution 4CIF real time (PAL: 704*576, NTSC: 704*480) Playback resolution 4CIF/DCIF/2CIF/CIF/QCIF real time 8/16 channels BNC (1.0Vp-p, 75Ω) Video input Main video output 1 channel, BNC (1.0Vp-p, 75Ω) Aux video output 1 channel, BNC (1.0Vp-p, 75Ω)
Page 109
User Manual of D1 Series Net DVR Working humidity 10%--90% Size 19” Standard (450mm*450mm*95mm) ≤8Kg (without HDD and CD-R/W) Weight PAL: 176*144(QCIF), 352*288(CIF), 704*288(2CIF), 528*384(DCIF), 704*576(4CIF); NTSC: 176*120(QCIF), 352*240(CIF), 704*240(2CIF), 528*320(DCIF), 704*480(4CIF). Page Total...
User Manual of D1 Series Net DVR Appendix D Quick Search Function Table Type Name Description Index User Create and delete users. System has one default management administrator. The administrator can create 15 users Safety and define their rights. function Password Modify password.
Page 111
User Manual of D1 Series Net DVR Remote Remote record real time stream. record Remote Remote playback the recorded files in DVR playback Download Download recorded files in DVR. Remote Remote upgrade firmware. upgrade Transparent Remote control serial device connected with serial 5.16...
User Manual of D1 Series Net DVR Appendix E Troubleshooting Failure Possible reasons After plugging in power, turning on the power switch, Power cable is broken. “POWER” light in front Panel does not turn on, and fan Power supply is broken.
User Manual of D1 Series Net DVR password, ect). Old player SDK (playm4.dll) Notes: Place the DVR in well ventilated space so that it operates within the allowed range of temperature and humidity as in specification. If the circuit board is wet, dust on circuit board can cause a short circuit. The circuit board, plug and socket, housing fan and housing should be cleaned by brushing regularly.
Need help?
Do you have a question about the D1 Series and is the answer not in the manual?
Questions and answers