  • Page 1 Owner’s Manual Series 1000 Inverter / Power Backup Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1000-065 REV B, 7/09 Copyright 2001 DoorKing, Inc. All rights reserved.
  • Page 2 Page 2 1000-065-B-7-09...
  • Page 3 Use this manual with the following models only. Model 1000-080, 1000-081 with circuit board 2355-010. DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes.
  • Page 4 Page 4 1000-065-B-7-09...
  • Page 5: Table Of Contents

    Table of Contents Important Information ..........................6 Important Precautions ..........................6 Specifications ............................8 Mounting..............................9 Read Before Wiring ..........................10 Wiring Instructions ............................10 LED Status Indicators..........................12 Battery Test and Reset Push Buttons ......................12 Switch Settings / Terminal Description.....................14 Status report .............................16 Replacement Items and Accessories .......................17 1000-065-B-7-09 Page 5...
  • Page 6: Important Information

    SAVE THESE INSTRUCTIONS! The 1000 Watt Inverter (1000-080) can be used to power a single, 1/2 HP gate operator system when in continuous duty mode, or can be used with two (2) 1/2 HP gate operators when open upon power failure mode is used.
  • Page 7 INPUT POWER OUTPUT POWER CAUTION – RISK OF ELECTRICAL SHOCK PRESENT! CAUTION – Risk of electrical shock – hazardous live parts inside this unit are energized from the battery supply even when AC power is disconnected . CAUTION – Risk of electrical shock. AC Input and AC Output terminals can be energized even with AC INPUT and AC OUTPUT switches turned off .
  • Page 8: Specifications

    ± 10% Output Wave Form: Modified Sine Wave DC Input Voltage: 10 – 15 VDC Low Battery Alarm: 10.5 VDC ± .5 V (1000-080) 9.5 VDC ± .5 V (1000-081) Low Battery Shutdown: 9.5 VDC ± .5 V Frequency: 60 Hz...
  • Page 9: Mounting

    Mounting The Model 1000 inverter has three (3) mounting holes provided on the back of the cabinet. The mounting holes should be used to mount the model 1000 to a vertical surface. In addition, there are five (5) 3/4” conduit knockouts; three (3) on the bottom and two (2) on the back. These should be used for wiring.
  • Page 10: Read Before Wiring

    Read Before Wiring WARNING! Do not connect batteries until installation and wiring is complete. The batteries will be the last component to be connected. Wiring of the Model 1000 should be performed by a qualified licensed electrical contractor to insure that the installation complies with local codes and ordinances. The output of the Model 1000 should at no time be connected to public power or a generator.
  • Page 11 Insure that both AC Power Input and AC Power Output switches are in the OFF (down) position before connecting any wires. 1000 Watt inverters (1000-080) can use one (1) or two (2) batteries; 1500 Watt inverters (1000-081) use two (2) batteries.
  • Page 12: Led Status Indicators

    LED Status Indicators The Model 1000 has 12 LED indicators to show the status of the inverter, batteries and to assist in troubleshooting. Description UTIL OPER GREEN LED indicating that the 115 VAC power output at J2 is sourced from the utility company and the inverter is in stand-by mode.
  • Page 13 SHDN INPUT POWER OUTPUT POWER BATT UTIL OPER TEST DIAGNOSTIC INV ON B BAD B OK BULK 110V ON TRICK TEMP HRT BEAT RESET 1000-065-B-7-09 Page 13...
  • Page 14: Switch Settings / Terminal Description

    Switch Settings / Terminal Description Switch Settings (settings in bold are default settings) SW # Description Low Battery HIGH – Shutdown occurs at a higher LOW – Shutdown occurs at a lower battery Shutdown battery voltage. Use with heavier voltage. Use with two battery systems gates.
  • Page 15 SHDN INPUT POWER OUTPUT POWER BATT UTIL OPER TEST DIAGNOSTIC INV ON B BAD B OK BULK 110V ON TRICK TEMP HRT BEAT 1 2 3 4 5 6 7 8 9 10 RESET 1000-065-B-7-09 Page 15...
  • Page 16: 10. Status Report

    10. Status Report The Model 1000 Inverter has a status report function that can be downloaded to a PC using a DB-9 connector and the RS-232 Serial port (refer to the table on page 14 for DB-9 wire connections). This feature can be used for troubleshooting purposes.
  • Page 17: Replacement Items And Accessories

    11. Replacement Items / Accessories Part Number Description 1000-048 12 Volt, 35 AH Battery and Cable Assembly. Order this to add a second battery to the 1000 Watt inverter system. 1801-005 12 Volt, 35 AH replacement battery. 1000-044 Battery Cables. 2355-010 Circuit Board 0500-033...