Thank you for selecting SteriPEN
research, development and testing have gone into this unique
UV water purification product.
Directions for Use 40 C.F.R. §156.10(i)(2)
It is a violation of Federal law to use this product in a manner inconsistent
with its labeling. 40 C.F.R. §156.10(i)(2)(ii)
SteriPEN
purifiers meet or exceed U.S. EPA Guide Standard and Protocol for
®
Testing Microbiological Water Purifiers, destroying over 99.9999% of bacteria,
99.99% of viruses, and 99.9% of protozoa (giardia & cryptosporidium) when
used as directed. SteriPEN
SteriPEN
Protector
®
Opti
opening of 4.4 cm (1.75 in.).
Operating the SteriPEN® Protector
Quick Start Guide
Use SteriPEN
Protector
®
should be pre-filtered until clear prior to SteriPEN
See also "Treating Turbid, Murky, or Cloudy Water."
SteriPEN
Protector treats two ranges of water volume:
®
A—between 0.5 – 1 L (16 – 32 fl. oz.)
B—up to 0.5 L (16 fl. oz.)
1
1
2
Opti
3A Push Activation button once – green indicator LED
3B Push Activation button twice – green indicator LED
2
4
3
4
5
5
6
6
7
7
Protector
. Years of careful
®
Opti
Protector
is not a sterilizer.
®
Opti
requires use in bottles or containers with a minimum
Opti
with clear water. Discolored or dirty water
Opti
Protector treatment.
®
Install two CR123 batteries with polarities as
shown; or install one double-cell CR123 battery.
Tighten coin screw on battery end cap until snug (do
NOT over-tighten screw as this may cause damage).
Remove lamp cover – pull cover off body.
(near button) and white optical sensor (near lamp)
will flash for up to 15 seconds indicating Protector is
ready to treat up to 1 liter (32 fl. oz.).
(near button) and white optical sensor (near lamp)
will flash for up to 15 seconds indicating Protector is
ready to treat up to .5 liter (16 fl. oz.).
While green indicator LED and white optical sensor
flashes, dip the ultraviolet (UV) lamp into the water
to be treated such that lamp and optical sensor are
completely immersed. When water is detected, lamp
turns on automatically, emitting both UV and visible
light. IMPORTANT NOTE: If visible light from UV lamp
is not evident, the Protector UV lamp is not on, and
water should not be consumed.
Agitate the water throughout the dose by stirring with
the Protector until the lamp automatically turns off.
Once lamp turns off, green indicator LED will turn on
to show that the UV dose is complete. NOTE: If red
LED turns on after lamp shuts off, the dose was not
complete.
Remove Protector from water. Dry off lamp and opti-
cal water sensor with clean cloth. IMPORTANT NOTE:
Many brands of CR123 batteries have built-in protec-
tion circuitry that instantly disables battery function
when batteries reach a specific low charge threshold.
If this "disable" function is triggered during operation
the Protector will be unable to give the "Low Battery"
signal (blinking red LED). Until batteries are replaced
or recharged the Protector will not be operational.
To activate the flashlight, press and hold the activa-
tion button for 3 seconds. The flashlight will automati-
cally be on for 3 minutes; reactivate as needed. To
turn off the flashlight, push the activation button once.
To protect UV lamp when using the flashlight, operate
with lamp cover in place.
Safety
SteriPEN ® Protector
may be used in glass, plastic, ceramic or metal
Opti
containers. They all absorb and reflect UV light, thereby shielding the user from
UV exposure. Protector
should not be used in quartz containers. The air/
Opti
water interface at the top of any drinking container is highly reflective to UV and
reflects UV back into the container.
Optical Water Sensor
SteriPEN
Protector
features an advanced proprietary optical water sensing
®
Opti
technology. This is an important safety feature intended to prevent UV exposure
by permitting operation only when lamp is completely immersed in water. Never
attempt to bypass this feature. If the SteriPEN
Protector
®
water within 15 seconds of being activated, it will deactivate.
Protector Opti LED (Light Emitting Diode) Signals
SteriPEN
®
LED Color and Pattern Display
Indication
Operating Signals
Green, fast flashing (after
Unit is armed and ready to
button push)
treat water
Green, slow flashing: 1 second on,
32 fl. oz. (1 L) dose completed
1 second off (after dose completion)
Green, steady (after dose
16 fl. oz. (0.5 L)
completion)
dose completed
Green blinks for 15 seconds
Time expired, try again. The user has
followed by a quick Red flash
15 seconds to put the SteriPEN
purifier in water after activation.
Red, steady
Dose incomplete. Repeat treatment.
Battery Warnings
Red, fast flashing
Low battery warning; replace or
recharge batteries
32 fl. oz. (1 L) dose completed;
Green slow blinking with
low battery
Red flashes
16 fl. oz. (0.5 L) dose
Green, steady with
completed; low battery
Red flashes
(1) Check battery orientation
LED will not come on
(2) Charge or replace batteries
(3) Clean battery contacts
(4) Return SteriPEN
Lamp Warnings
Red 2 flashes, Green 2 flashes
Over 7,900 treatments completed;
lamp replacement needed in under
(repeating)
100 doses
Lamp failure; replace lamp
Red 3 flashes, Green 1 flash
(repeating)
Lamp failure. Do not consume water.
Normal indicator LED function,
yet UV lamp emits no visible light
No LED indicator and UV lamp
Battery issue or Lamp failure; Try
fresh batteries, then contact support
emits no visible light
Agitation of Water
Agitation of the water by stirring with Protector
Opti
throughout the dose is essential for proper operation as this insures uniform
exposure of all water to germicidal UV light.
Cold Weather Considerations
Bring Protector
up to a temperature above 32°F/0°C
Opti
before using. B attery performance may be adversely affected by cold
weather.
Lamp Life
Lamp Life = 8,000 Treatments, lamps must be replaced
by manufacturer or SteriPEN
technician.
®
does not detect
Opti
®
purifier for repair
®
or rocking the container