1.1XP EINS USER'S MANUAL

Congratulations and thank you for purchasing a SEEMANN XP EINS dive computer. As of today you will be accompanied by the latest
generation dive computer using the most sophisticated technology. It is specifically designed to guarantee maximum safety for your
dives.
SAFETY PRECAUTIONS
Just like all dive computers, the XP EINS gives the diver important data. But it does not offer the context the diver must be fully aware of
and furthermore understand to interpret that data in practice. A dive computer is never a substitute for common sense, proper training
and diving certification.
Do not attempt to use your XP EINS without reading this instruction manual completely, including all warnings, and make sure you fully
understand the use, displays and limitations of your XP EINS.
Always remember that you are responsible for your own safety.
WARNING!
Recreational diving is a sport that involves certain risks. There is always a risk of decompression illness (DCI), oxygen toxicity and other
risks related to diving with NITROX or compressed air even if following the instructions given in this user's manual carefully. If you are
not fully aware of all risks, and if you do not wish to take the sole responsibility, do not use the XP EINS. Risks are not always obvious
and require training to understand and avoid. Risks can include injury or death.
The XP EINS was programmed exclusively for diving with NITROX (max. 99% O2) and compressed air (21% O2). Do not attempt to
dive with any gas mix other than compressed air or NITROX.
Before the dive, make sure you have correctly set all the NITROX dive parameters: percentage of oxygen in the mix and limit for the
partial pressure of oxygen, which together determine the maximum depth of the dive. Always be aware that if an incorrect gas mixture is
entered, the decompression time calculation may be incorrect, as may be the calculation of the percentage of oxygen (PPO2) in the mix.
The maximum discrepancy between the entered PPO2 and the measured PPO2 of the mixture shall not exceed 1%. Incorrect data
entry can cause serious injury or death!
Always pay attention to the visual and acoustic signals of the XP EINS;
Never exceed the maximum permitted depth according to the gas mixture in use during NITROX dives.
Always check the limits for the dive you are preparing for.
In doing so, pay attention to the PPO2 of the gas mixture and the standard safety precautions for recreational diving
(decompression illness, oxygen toxicity)
As taught in all diving courses, never exceed a depth of 40 meters (130 ft.). The risk of oxygen toxicity must be considered at
all times, and the XP EINS does not warn you of that risk.
Make a safety stop of a minimum of three minutes at 5 meters (16ft.) in all your dives with the XP EINS. The XP EINS offers a
safety stop timer that simplifies this factor, if used correctly.
Any diver using a dive computer for monitoring his/her decompression status must use an individual computer. This individual
computer must be used for all dives carried out within a short period.
Should the XP EINS malfunction at any time during a dive, abort the dive, ascending slowly. You will still have to make your
safety stop at 5 meters (16 ft.) for three to five minutes.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XP EINS and is the answer not in the manual?

Questions and answers

Summary of Contents for Seemann XP EINS

  • Page 1: Table Of Contents

    NITROX or compressed air even if following the instructions given in this user’s manual carefully. If you are not fully aware of all risks, and if you do not wish to take the sole responsibility, do not use the XP EINS. Risks are not always obvious and require training to understand and avoid.
  • Page 2: Introduction

    • Before using the XP EINS you need to be acquainted with the signs and symptoms of DCI: Should you feel any of these signs or symptoms then seek specialized medical advice IMMEDIATELY. The earlier a diver gets medical treatment after appearance of symptoms, the more efficient the treatment will be.
  • Page 3: Watch Functions

    Time Mode If you use your XP EINS on the surface, it will run in the Time Mode. Your computer has two different displays in this mode: Normal and Alternative. After changing any setting, and five minutes after finishing a dive it will return to this mode (Fig.
  • Page 4 Secondary time zone The XP EINS observes current time in two time zones, a great benefit to divers who like to travel. The secondary time zone can differ by up to 23 hours and 30 minutes from the main time zone and is displayed by pressing the ‘Select’ key. The ‘DUAL’ is also displayed.
  • Page 5: Dive Computer Functions

    NITROX dives If you dive with NITROX gas mixtures, you will need to enter the percentage of oxygen in the gas mixture into your XP EINS. It is very important that the oxygen percentage of the gas mixture complies with the percentage in the tanks, as this value will be used as a basis...
  • Page 6: Advanced Time Functions

    Secondary time zone The XP EINS observes current time in two time zones, a great benefit to divers who like to travel. The secondary time zone can differ by up to 23 hours and 30 minutes from the main time zone and is displayed by pressing the ‘Select’ key. The ‘DUAL’ is also displayed.
  • Page 7: Advanced Dive Computer Functions

    (NX) starts to flash. If you access dive mode after resetting the FO2 an alarm will be triggered. In case you should ignore the alarm and start a dive without the setup of a new FO2-value, the XP EINS will start its calculations with a gas mixture of 99% O2 – 79% nitrogen.
  • Page 8 Saved data can be transferred to a computer with PC software LogBook and the relevant interface. You can order an interface and software from your authorised SEEMANN dealer. As soon as you have installed the interface on your PC with the USB connection, you...
  • Page 9: Technical Specifications And Maintenance

    The battery power level is checked every ten minutes in all modes except for Dive Mode and Data Transfer Mode. If the XP EINS detects a drop in battery power the relevant symbol starts to flash. If battery power drops again, the symbol is shown continuously and Dive Mode is deactivated.