Zenith P42W34P Service Manual page 9

Table of Contents

Advertisement

EXTERNAL CONTROL DEVICE SETUP
Set ID
Set ID
Use this function to specify a monitor ID number.
Refer to 'Real Data Mapping 1'. See page 28.
1. Press the MENU button and then use
2. Press the
G G
button and then use
3. Press the
G G
button and then use
monitor ID number. The adjustment range of
4. Press the ENTER button to save.
Communication Parameters
Communication Parameters
• Baud rate : 115200 bps (UART)
• Data length : 8 bits
• Parity : None
* Use a crossed (reverse) cable.
Command Reference List
Command Reference List
COMMAND 1 COMMAND 2
01. Power
02. Input Select
03. Aspect Ratio
04. Screen Mute
05. Volume Mute
06. Volume Control
07. Contrast
08. Brightness
09. Color
10. Tint
11. Sharpness
12. OSD select
13. Remote control lock mode
14. PIP/DW
15. PIP size
16. Split Zoom
17. PIP position
18. Treble
19. Bass
20. Balance
21. Color temperature
22. Red adjustment
23. Green adjustment
24. Blue adjustment
25. PIP input source
26. Abnormal Status
27. ISM Method
28. Low Power
29. Orbiter Time Setting
30. Orbiter Pixel Setting
31. Picture Size Setting
for Double Window mode
32. Auto Config
When setting the 27 ~ 32, a menu doesn't display on
screen.
button to select the
D D / E E
button to select
D D / E E
Set ID
F / G
button to adjust
is 1 ~ 99.
Set ID
• Stop bit : 1 bit
• Communication code : ASCII code
DATA
(Hexadecimal)
k
a
0 ~ 1
k
b
0 ~ 4
k
c
0 ~ 3
k
d
0 ~ 1
k
e
0 ~ 1
k
f
0 ~ 64
k
g
0 ~ 64
k
h
0 ~ 64
k
i
0 ~ 64
k
j
0 ~ 64
k
k
0 ~ 64
k
l
0 ~ 1
k
m
0 ~ 1
k
n
0 ~ 3
k
o
0 ~ 1
k
p
21 ~99
k
q
0 ~ 3
k
r
0 ~ 64
k
s
0 ~ 64
k
t
0 ~ 64
k
u
0 ~ 3
k
v
0 ~ C8
k
w
0 ~ C8
k
$
0 ~ C8
k
y
0 ~ 4
k
z
0 ~ a
j
p
0 ~ 3
j
q
0 ~ 1
j
r
1 ~ FE
j
s
0 ~9
j
t
0 ~64
j
u
1
menu.
SPECIAL
.
to choose the desired
Set ID
T
ransmission / Receiving Protocol
T
ransmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1]: First command to control PDP set. (j or k)
* [Command 2]: Second command to control PDP set.
* [Set ID]: You can adjust the set ID to choose desired monitor
ID number in special menu. Adjustment range is 1
~ 99. When selecting Set ID '0', every connected
PDP set is controlled. Set ID is indicated as deci-
mal (1~99) on menu and as Hexa decimal
(0x0~0x63) on transmission/receiving protocol.
* [DATA]: To transmit command data.
Transmit 'FF' data to read status of command.
* [Cr]: Carriage Return
ASCII code '0x0D'
* [ ]: ASCII code 'space (0x20)'
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving abnormal data from non-viable
functions or communication errors.
Data 1: Illegal Code
2: Not supported function
3: Please Wait
- 9 -
SPECIAL
SPECIAL
Language
Key lock
ISM Method
Low power
G G
Set ID
1
Caption / Text
Captions
OSD Rotate
MENU
Prev.

Advertisement

Table of Contents
loading

Table of Contents