TECHNICAL MANUAL FOR
THERMOSYPHONIC SYSTEMS
Last Update: 2011-June
INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS
1/35
©TANSUG MAKİNA LTD. 2008

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECOSET 151 and is the answer not in the manual?

Questions and answers

Summary of Contents for OURASET ECOSET 151

  • Page 1 “CLOSEST TO THE SUN” SOLAR THERMAL SYSTEMS TECHNICAL MANUAL FOR THERMOSYPHONIC SYSTEMS Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 1/35 ©TANSUG MAKİNA LTD. 2008...
  • Page 2: Table Of Contents

    INDEX CHAPTER I ....................................INSTRUCTIONS FOR INSTALLER ............................. 3 INTRODUCTION ..................................3 COMPONENTS AND PHYSICAL CHARACTERISTICS ....................4 Solar panel ....................................... 6 2.3.1 Technical Spec Sheet ............................6 2.3.2 Efficiency Curve ..............................6 2.3.3 Cross Section of the Solar Panels ........................8 Technical Specifications of Horizontal Boilers ........................
  • Page 3: Chapter I

    Buying an OURASET is a gift to the “PLANET EARTH” as well as to the future generations. OURASET solar water heater system is designed to provide problem free hot water for many many years.
  • Page 4: Components And Physical Characteristics

    COMPONENTS AND PHYSICAL CHARACTERISTICS Thermosyphonic Systems at a glance *Capacity is estimated based on average daily hot water generation capacity calculated on the insulation values between 36 parallel - Mediterranean climate. Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 4/35 ©TANSUG MAKİNA LTD.
  • Page 5 527,0 * In addition to to standard sets illustrated at section 2, various configurations are shown above. These schemes are illustrative only. OURASET manufactures systems with different tank configurations only on an OEM basis with sufficient volume. *Refer to Section 4 : “Shading Scheme”...
  • Page 6: Solar Panel

    Solar panel 2.3.1 Technical Spec Sheet Technical Specifications of the Panels – AA and AES MODEL AA 950 AA 1200 AES 950 AES 1200 Dimensions 950x1950 x105 mm. 1200x1950x105 mm. 950x1950x105 mm. 1200x1950 x105 mm. Net absorption area 1,57 m 2,07 m 1,57 m 2,07 m...
  • Page 7 Test Report for AA 1200, by CENER under SOLAR KEYMARK Scheme Test Report and efficency curve for AA 950, by CENER under SOLAR KEYMARK Scheme Test Report and efficency curve for AES 1200, by CENER under SOLAR KEYMARK Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 7/35 ©TANSUG MAKİNA LTD.
  • Page 8: Cross Section Of The Solar Panels

    2.3.3 Cross Section of the Solar Panels ITEM SOLAR PANEL Black painted (AES) / selective coated (AA) copper absorber 10 channel (1200) - 8 channel (950) Ø 10 Copper tubes Ø 22 Copper tube header manifold Hexagonal brass union Insulation 50mm Rock wool W/m °C:0,055 (AA) Glasswool W/m °C:0,036 (AES) Glasswool insulation 20mm...
  • Page 9: Technical Specifications Of Horizontal Boilers

    Technical Specifications of Horizontal Boilers HIGHLIGHTS OF OURASET P SERIES * Aesthetic Uv resistant ABS Plastic Caps designed for easy handling * Minimum heat loss due to dense polyurethane insulation * Enatech porcelain enamel coating to ensure hygienic water * Electrical heater inlet and cap available...
  • Page 10 2.4.1 Horizontal Boilers, Middle connection (M), CLOSE loop (CL) P 190M / CL P 300M / CL Ф DESCRIPTION NOZZLE Cold water inlet 3/4" Hot Water Outlet 3/4" Solar Collector Outlet 3/4" Return to Collector 3/4" Expansion Tank Kit Connection 3/4"...
  • Page 11 2.4.2. Horizontal Boilers, Side connection (S), OPEN (OL) or CLOSE (CL) loop P 120S / CL P 120S / OL P 150S / CL P 150S / OL P 190S / CL P 190S / OL P 300S / CL P 300S / OL OPEN LOOP CLOSE LOOP...
  • Page 12 2.5 Components and Accessories Component Brand* Technical Features More Specs • See Section 6 for details Structures 40x40x4 mm, perforated L profile, electrogalvanized • Extruded aluminum profile 6 or 7 lt capacity, precharged to 1 bar, Expansion Tank ** Varem Dimensions: Ø385x92 mm max.
  • Page 13: General Instructions- Preperations For Installation

    3.5 You may need the following tools and devices for the installation of your OURASET system: a. Small crane - for the lift of panels and stand on the roof b.
  • Page 14: Installation Of Panels

    4. INSTALLATION OF PANELS 4.1 Placement of Panels: The panel should face the direction of the equator. Panel should face South in the Northern and North in the Southern Hemispheres. Use a compass to determine the true south. 4.2 Panel Angle: The general application is that the panel is installed at the same angle as the latitude of your location at all locations outside of the Tropic Zone.
  • Page 15: Installation Of The System

    Descripción Sistemas de Sistemas 1 captador de 2 captadores Cantidad Cantidad Ouraset Collector Ouraset Tank Blind Plug ¾´´ Security valve 3 bar ½´´ female Security Group 6 bar ½ ´´ Elbow ¾ ´´ MM Adapter ¾ ´´ - ½´´ Ball valve ½´´ MF...
  • Page 16: Installation Of Double- Panel Systems

    5.2 Installation of Double- Panel Systems Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 16/35 ©TANSUG MAKİNA LTD. 2008...
  • Page 17: Modular Roof-Top Stand

    MODULAR ROOF-TOP STAND Your Modular Compact System Structure is designed to be compatible among different models. By changing only 1-2 parts you can build up all the different models of structures that you may require. NOTE: There are also many common parts in the thermosyphonic stand parts that you can also use to build up Villaset Stands.
  • Page 18: Description Of Screws That Are Used In The Mounting Of The Stands

    6.3 Description of screws that are used in the mounting of the stands. You will use two kinds of screws that will be sent with your structure. TYPE 2 TYPE 3 TYPE 2 : Standard Structure Assembly Screws TYPE 3 : Flat Head Screws- used for connection of tank support bed to wind belt...
  • Page 19 6.4.7 Put your structure on the desired location on the roof to mark the points on which you want to anchor the ground support (I). 6.4.8 Put the structure aside and drill the holes on the roof and insert plugs and nuts. Anchor the ground supports (I) on the roof.
  • Page 20 FIGURE A: TFR45-1: T. Syphonic flat Roof Structure for 1 Panel 880 mm 45° Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 20/35 ©TANSUG MAKİNA LTD. 2008...
  • Page 21 FIGURE B: TFR45-2: T. Syphonic Flat Roof Structure for 2 Panels 45° Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 21/35 ©TANSUG MAKİNA LTD. 2008...
  • Page 22: Assembly Of Thermosyphonic Flat Roof Stand (Tfr35)

    6.5 Assembly of Thermosyphonic Flat Roof Stand (TFR35) By changing only two parts (B,C) that are listed at Section 2, you can easily convert your flat roof structure from 45° inclination to 35°. During your installation you just need to take into account the dimensions illustrated in Figure C, below: FIGURE C: TFR35-1 /2: T.
  • Page 23 for systems 121-151-191 when connecting the back diagonals. Use the holes on the vertical frames (B) that correspond to this distance between the two legs. (See Figure A) 6.5.4 The distance between the two legs must be 1260 mm. for structure type TIR45-2 for systems 192-302.
  • Page 24 6.5.7 Remove the tiles on the roof and identify the location on the wooden, steel or concrete beams on which it is possible to screw the roof anchors (J). Install the roof anchors on the suitable locations alongside the beams. Try to locate the anchors in a way that one pair is at the bottom and the other two pairs are closer to the top.
  • Page 25 FIGURE E: Connection Details for Inclined Roof Assembly – Using C45 FIGURE F: Connection Details for Inclined Roof Assembly – Using C35 Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 25/35 ©TANSUG MAKİNA LTD. 2008...
  • Page 26 5. CHARGING THE SYSTEM Important points in the connection of the system to the house plumbing: 5.1.1 Install the equipment in such a way that the thermotank stays the closest possible to the consumption points. The maximum distance between the collector and the most distant consumption points should be around 30m, linear.
  • Page 27: Electrical Element

    MODEL P 101 P 121 P 151 P 191 P 192 P242 P 302 Close Loop Volume (lt.) 9,00 12,00 13,00 14,00 15,00 20,00 21,00 ºC Temperature AFLUS 1,35 lt 1,80 1,95 2,10 2,25 3,00 3,15 WATER 7,65 lt 10,20 10,20 11,90 12,75 17,00 17,85 AFLUS 1,80 lt...
  • Page 28 On the side of your electrical element, there is a screw that goes through the body of the element. The third hose is reserved for grounding. Connect this hose to the screw attached to the body of the electrical element. Make sure that your home’s electrical circuit has grounding.
  • Page 29 Connect the Then connect the negative and positive grounding line on poles to the respective the cable. lines on the cable. Screw the heater cap on the tank. Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 29/35 ©TANSUG MAKİNA LTD. 2008...
  • Page 30: Aflu-S Heat Transfer Fluid

    AFLU-S HEAT TRANSFER FLUID Aflu-S is a special non toxic propylene glycol heat transfer fluid used in the close circuit of your system to provide better heat transfer at the same time protecting your system from corrosion and frost. Freezing Point: 60°...
  • Page 31: Chapter Ii

    CHAPTER II INSTRUCTIONS FOR THE USER WARNING: Make sure that all installation is carried out by your authorized installer. Check all valves are properly working and the system is completely filled with water and antifreeze fluid. In case of failure, read the instructions at the troubleshooting section. Always call your authorized service store before taking any action.
  • Page 32: Cleaning Panels

    13.1 Cleaning Panels: Regular rainfall keeps your panels clean. In dusty or drought areas, it is recommended that panels are cleaned by the help of warm water and sponge when necessary. 13.2 Pipe Insulation: Insulation material for piping may worn out in time due to strong UV rays. Renew when necessary.
  • Page 33 o Do not let the water running when there is no need. o Use the hot water at a reasonable temperature (around 42 ° C) o If the water pressure at your house is excessive, install a pressure reducer. 14.2 Proper Installation When properly located (facing the right direction, installed in the right angle, located on an unshaded spot, etc) your system should work at its best.
  • Page 34: Annex 1: Parallel Connection Of Multiple Systems

    ANNEX 1: PARALLEL CONNECTION OF MULTIPLE SYSTEMS ANNEX 2: SERIAL CONNECTION OF MULTIPLE SYSTEMS Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 34/35 ©TANSUG MAKİNA LTD. 2008...
  • Page 35 CONTACT DETAILS TANSUĞ MAKİNA INDUSTRIAL FACILITIES ADANA-CEYHAN YOLU 10. KM 01340 INCIRLIK ADANA TURKEY 90-322-3464900 90-322-3465008 info@ouraset.com WWW.OURASET.COM “CLOSEST TO THE SUN” Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS 35/35 ©TANSUG MAKİNA LTD. 2008...