Remotely Control Air‐Conditioner by SMS Text! Temperature Monitoring by SMS Text! GSM SMS IR CONTROLLER RTU5016 User Manual Ver 1.0 Date Issued: 2012-03-05 All rights reserved by King Pigeon Hi-Tech. Co., Ltd. Website: Http://www.GSMalarmsystem.com Page 1 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 1 of 16 Ver 1.0...
We recommend that the advice of a registered electrician be sought before any Installation work commences. King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook.
Monitoring, Automatically monitoring temperature with Air-Conditioner at preset temperature range. Moreover, the GSM SMS IR Controller RTU5016 equips with a relay output, can be used in places which require turning ON/OFF your system, machines, equipments remotely with a SMS Text command from your mobile phone.
Avoid signal shielded by covering the mainframe. Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer. 3. Standard Packing List Page 4 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 4 of 16 Ver 1.0 File No.:RTU501610...
IR Receiver, while learning the IR Signal, the IR’s IR Transmitter must face this IR Led. Learning IR Transmitter, must face the Air-Conditioner’s IR Receiver. IR TX Page 5 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 5 of 16 Ver 1.0 File No.:RTU501610...
ON or OFF the output relay automatically. 10) Secure - Using password for identification authorized users; 11) Based on GSM Network, applied to many applications. Page 6 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 6 of 16 Ver 1.0 File No.:RTU501610...
It is not product problem. For this problem, mainly caused by incorrect phone number format, please try to add the country code before the number, see the below settings: Page 7 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 7 of 16 Ver 1.0 File No.:RTU501610...
Page 8
E.g.: if you want to setup 13500001111 as the first user number, and the password is 1234,then you can send to the RTU5016 unit. After the RTU5016 received, the 0044 is 1234#TEL004413500001111#01# country code, will return: Page 8 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 8 of 16 Ver 1.0 File No.:RTU501610...
Page 9
IR ON/OFF Air-Conditioner value, the T2~T6 positions are for assigning IR Temperature value,. 6.6 Setup Low Temperature Alarm Value and Actions pwd#LOW#ON# 1) Enable low temperature alarm function: Page 9 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 9 of 16 Ver 1.0 File No.:RTU501610...
Page 10
The Air-Conditioner is not link to low temperature alarm occurrence. Reply: The Non-Link Air-Conditioner and Non-Link the relay output when low temperature alarm Tips: occurrence is default. Page 10 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 10 of 16 Ver 1.0 File No.:RTU501610...
Page 11
The Air-Conditiner is not link to High temperature alarm occurrence. Reply: The Non-Link Air-Conditioner and Non-Link the relay output when high temperature alarm Tips: Page 11 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 11 of 16 Ver 1.0 File No.:RTU501610...
(The T1~T6 value can be assigned to the GSM SMS IR Controller by used the Air-Conditioners’ IR Transmitter.) 6.11 Switch OFF Air-Conditioner pwd#OFF # Temp set 1 is PowerOff Will return 7. Operation & Installation Page 12 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 12 of 16 Ver 1.0 File No.:RTU501610...
Page 13
GSM SMS IR Controller T2 position operation successful. The Switch Button on IR’s panel only used for switch off the Air-Conditioner in the RTU5016. Tips: Page 13 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 13 of 16 Ver 1.0 File No.:RTU501610...
Page 14
ON/OFF equipments by SMS Text Command, Also the relay can be linked to the temperature threshold value, e.g.: when temperature is lower or higher than the threshold value, then Page 14 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 14 of 16 Ver 1.0 File No.:RTU501610...
9. Important information 1) Please read the User Manual carefully before you install the GSM SMS IR Controller and set the GSM SMS IR Controller. Page 15 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 15 of 16 Ver 1.0 File No.:RTU501610...
Operating Instructions. In no event shall the manufacturer be liable for any alarm system altered by purchasers. The End! Any questions please help to contact us feel free. Email Us: Sales@Kingpigeon.com.cn Http://www.GSMalarmsystem.com Http://www.Kingpigeon.com.cn Page 16 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 16 of 16 Ver 1.0 File No.:RTU501610...
Need help?
Do you have a question about the GSM SMS IR CONTROLLER RTU5016 and is the answer not in the manual?
Questions and answers