Page 1
Welcome to the Pureit Family As Safe As Boiled Water REACH PUREIT AT +254-715828161 +254-715828159 www.pureitwater.com...
Page 3
As Safe As Boiled Water Congratulations! Welcome to the Pureit Family! We thank you for the trust you have shown in our product and we guarantee you that our product will live up to your expectations. Pureit Excella is trusted by millions of users around the world for providing safe drinking water for their loved ones.
CONTENTS Pureit Excella Advantages ................3 Getting to Know Your Pureit Excella ............4 How Pureit Excella Works ..............5 Setting up Pureit Excella .................6 Ordering and Changing the Germkill Kit ..........8 Cleaning & Maintenance of Pureit Excella ..........16 Dos & Don’ts ..................23 FAQs .....................24...
PUREIT ExCELLA ADVANTAGES As Safe As Boiled Water No undesirable odour No plumbing No boiling Auto Shut-off No expensive bottled water Natural tasting water No electricity Food grade plastic No continuous tap water needed Zero maintenance Strong and durable World’s largest selling water...
GETTING TO KNOW YOUR PUREIT ExCELLA Top Lid Sediment Filter Top Cover Top Chamber Carbon Polisher Microfiber Mesh Batching Chamber Cleansing Collection Chamber Germkill Processor Germkill Life Indicator Germkill Life Indicator Cover Microcharged Membrane Assembly Transparent Chamber Pedestal...
HOW PUREIT ExCELLA WORKS Removes Uses visible dirt PGT - ‘Programmed Germkill Technology’ to target and remove harmful viruses and bacteria. Removes Removes harmful parasites, precipitated pesticides and chlorine, metallic making the water clear, impurities. odorless and natural tasting. Purifies...
SETTING UP PUREIT ExCELLA Open the box. Remove the Top Cover and keep it Remove the Transparent Chamber with the aside. Remove and discard the thermocol. pedestal and keep it aside. Discard the plastic film from it. Remove the Cleansing Collection Chamber, Wash hands thoroughly.
Page 9
Transparent Chamber. Cover and place it on the Top Chamber. Place the lid on the Top Cover. Pureit Excella is now ready for use from second cycle onwards. After fitting the Microcharged Membrane Assembly to the Cleansing Collection Chamber, do not rest the assembly on a flat surface.
Once the Germkill Life Indicator turns fully red, please replace the Germkill Kit immediately. As an additional measure of safety, Auto Shut-off mechanism of the Pureit Excella, shuts off the supply of purified water which ensures that no member of your family accidentally drinks unsafe water.
Page 11
Log on to locate your nearest dealer Call Pureit helpline to locate your nearest dealer The Germkill Kit consists of 3 parts Microcharged Membrane Germkill Processor Carbon Polisher There are multiple Pureit Germkill Kit(s) available. Please buy the one that is recommended for your Pureit model.
Page 12
ORDERING AND CHANGING THE GERMKILL KIT Remove Top Cover and Top Chamber. Empty the Slightly pull the Germkill Life Indicator Cover Bottom Chamber and Top Chamber completely. upwards and remove it from the purifier. Empty water from the Cleansing Collection Remove the Microcharged Membrane Assembly by twisting it in Chamber completely.
Page 13
ORDERING AND CHANGING THE GERMKILL KIT Rotate the Microfibre Mesh in the Remove it from the purifier. anti-clockwise direction. The Carbon Polisher will come out along with it. Remove the Carbon Polisher by rotating it in the Discard the old Carbon Polisher. anti-clockwise direction.
Page 14
ORDERING AND CHANGING THE GERMKILL KIT Wash the Microfiber Mesh Insert the new Carbon Polisher. under a jet of clean water. Rotate clockwise to fit. Replace the Microfiber Mesh and the Carbon Polisher Assembly in the purifier. Rotate clockwise to fit.
Page 15
ORDERING AND CHANGING THE GERMKILL KIT Wash hands thoroughly. Rotate the base Remove the Microcharged Hold the base and rotate the Membrane along with its base, Microcharged Membrane in the of the Microcharged Membrane Assembly from the holder. Keep the holder anti-clockwise direction.
Page 16
ORDERING AND CHANGING THE GERMKILL KIT Replace the Microcharged Membrane along with Insert the Microcharged Membrane the base in the Microcharged Membrane holder Assembly at the base of the Cleansing and rotate the base in clockwise direction to fit. Collection Chamber. Rotate clockwise to fit. Replace the Cleansing Collection Chamber on the Turn the Germkill Processor in Transparent Chamber.
Page 17
Chamber and push it downwards to fit. Replace the Top Chamber on the Fill the Top Chamber with water and drain out Cleansing Collection Chamber. all the water that collects in the Transparent Chamber. Refill the Top Chamber. Now your Pureit Excella is ready to use.
CLEANING & MAINTENANCE Of PUREIT ExCELLA Remove Top Lid and clean it with tap water. Leave it to Remove the sediment filter from the Top Cover and drip dry. clean it by gently squeezing it under a stream of clean water to dislodge the dirt and grime.
Page 19
CLEANING & MAINTENANCE Of PUREIT ExCELLA Slightly pull the Germkill Life Indicator Cover upwards Rotate the Germkill Processor in the and remove it from the purifier. anti-clockwise direction to remove and keep it in a safe place. Empty the water from the Wash hands thoroughly.
Page 20
CLEANING & MAINTENANCE Of PUREIT ExCELLA Rotate the Microfiber Mesh in the anti-clockwise Rotate the Carbon Polisher in the direction to remove. The Carbon Polisher will come out anti-clockwise direction to remove. along with it. Wash the Carbon Polisher in running water Wash the Microfiber Mesh under by gently scrubbing it with hands.
Page 21
CLEANING & MAINTENANCE Of PUREIT ExCELLA Fill Pureit water in the bellow pump. Insert the bellow pump into the nozzle at the bottom of the Carbon Polisher, the area opposite to side with handles given. Close the mouth of the carbon block with one hand...
Page 22
Ensure tightness. Ensure tightness. Wash the Transparent Chamber with clean Pureit water Fill Pureit water in the bellow pump. Insert the bellow and ‘drip dry’. pump into the nozzle provided at the bottom of the Microcharged Membrane Assembly.
Page 23
CLEANING & MAINTENANCE Of PUREIT ExCELLA Now hold the Microcharged Membrane base and Insert the Microcharged Membrane Assembly at the base squeeze the bellow pump to force water out of the of the Cleansing Collection Chamber and turn clockwise Microcharged Membrane Assembly. You can see dirt to fit.
Page 24
(50 ppm available chlorine). Pour in Top Chamber. water till the top of the Top Chamber and drain out all the water that collects in the Transparent Chamber. Refill the Top Chamber. Pureit Excella is now ready for use from second cycle onwards.
DOs & DON’Ts Pureit Excella has been specially designed to give you as safe as boiled water as long as the Pureit system is used in the way as prescribed in this manual. Listed below are the things that you must take care of: DON’Ts...
How long does it take for the water to get purified? Membrane has been damaged. Please visit your nearest It depends on the quality of water that is put into Pureit Excella. Pureit Excella dealer to purchase new one or call us at the Typically 9 litres of water gets purified between 1.5-2 hrs.
TECHNICAL SPECIfICATIONS fOR PUREIT ExCELLA Pureit Excella Height 61 cms Width 33 cms Depth 36 cms Weight 3.7 kgs Total purifier volume 23 litres Water storage capacity 9 litres Material of construction Food safe, non-toxic, engineering plastics Germkill Kit Material of construction...
Page 28
- Srilanka - Kenya - Ghana - Uganda 1 choice of Pureit is the world’s families worldwide largest selling water purifier brand * Based on Unit shipment sales for 2010. Excludes pitchers and faucet mount system sales and includes only in-home...
Need help?
Do you have a question about the EXCELLA and is the answer not in the manual?
Questions and answers