When the total current over 25A, EDX-607 will stop outputting and press OFF ¡ button to reset; when the total current over 20A, EDX-607 will limit the output till the total current lower than 16A and press any scene button to reset.
ISO 9001 CERTIFIED www.liteputer.com.tw 1-6 Panel introduction Scene buttons IR receiver Channel dimming value display or other function meaning Function buttons CH1- CH12 dimming value UP CH1- CH12 dimming value DOWN Lite-Puter EDX-607E [EUM-A]...
ISO 9001 CERTIFIED www.liteputer.com.tw Chapter 2. Operation Description 2-1 Function Introducing Long hold FCN for 3 seconds and then press FCN to select a function from the following list: Display Combined Button Function FCN + CH1_UP Set ID No. FCN + CH2_UP Set Zone No.
2-3 DMX Start Channel Setting The standard DMX console can output 512 channels, while EDX-607 must select 12 continuous channels from these 512 channels. The first channel’s address of the 12 continuous channels is EDX-607’s DMX start channel address.
ISO 9001 CERTIFIED www.liteputer.com.tw STEP-1Press FCN + CH2_UP at the same time or long hold FCN for 3 seconds to enter function menu and then press FCN once to select function ,the screen will display the zone code ▲ ▼ STEP-2Press to adjust the value;...
Page 12
ISO 9001 CERTIFIED www.liteputer.com.tw Example: To set channel 1 to partition 2, channel 10 to partition 3 and other channels to partition 1 (default). The steps are as follows. 1. Enter . The LED bars of channel 1 ~ 6 show all of them are in partition 1. 2.
Page 13
ISO 9001 CERTIFIED www.liteputer.com.tw y y y y y y y y y y y y 4. Press CH1_UP to set channel 1 to partition 2, the LED bar shows that channel 1 is in partition 2 now. &+B83 5. Press once to shift to partition 3.
ISO 9001 CERTIFIED www.liteputer.com.tw 6. Press S shift to channel 7 ~ 12. 7. Press CH10_UP to set channel 10 to partition 3. &+B83 8. Press ENTER to save and exit. 2-6 ID_NO Setting Each EDX Series device has its ID number (default value: 001). If more than one EDX devices are connected together, each of them has to be set ID number.
ISO 9001 CERTIFIED www.liteputer.com.tw ▲ ▼ STEP-2Press to select the ID number from 1 to 999. STEP-3Press ENTER to save and exit. 2-7 Fade Time Setting STEP-1 Long hold FCN for 3 seconds to enter function menu and then press FCN 3 times to select the function or press FCN + CH4_UP at the same time, the screen will display the fade timeFFdFsetting as: .Then press...
ISO 9001 CERTIFIED www.liteputer.com.tw 1.Long hold FCN for 3 seconds to enter function menu and then press FCN 4 times to select the function or press FCN + CH5_UP at the same time, the screen will display, 2.Press ENTER to edit the clock, it will display, ▲...
Example: means the current temperature is 30° C. When the internal temperature over 62° C, EDX-607 will limit the output and decrease to 0% smoothly till the temperature below 55° C ; when it over 65° C, EDX-607 will stop output immediately.
ISO 9001 CERTIFIED www.liteputer.com.tw Note: When the timer on, EDX-607 will recall the scene automatically. STEP-3 Press ENTER to save and exit. STEP-4 If you need add more record, press to add another record and the setting steps as above.
ISO 9001 CERTIFIED www.liteputer.com.tw y y y y y y y y y y y y y While edit the dimming value of channel 4, the screen will display as and the right side of which will display the dimming value. The dimming values also showed on the LED bar.
ISO 9001 CERTIFIED www.liteputer.com.tw ▲ ▼ 2. Press to increase all channels’ dimming value, or press to decrease all channels’ dimming value. 3.Press ENTER the dimming value of current channel will increase or decrease at a speed of 25%. 4.Hold DOWN button of current channel, and then press UP the current channel’...
STEP-1Long hold FCN for 3 seconds to enter function menu and then press FCN till the screen displays ▲ STEP-2Press to turn on IR remote control( EDX-607 under the IR remote ▼ to turn off IR remote control FEDX-607 out of IR remote controlF . control)or press STEP-3After setting, press ENTER to save and exit.
STEP-2 Press ▲ to enable clock synchronization, the screen displays Fpress press ▼ to disable clock synchronizationFthe screen displays ENTER to save and exit. If clock synchronization is enabled, all EDX-607 in the same zone will be synchronized at 12:00 every day. Lite-Puter EDX-607E [EUM-A]...
ISO 9001 CERTIFIED www.liteputer.com.tw Safety Precaution The setting of dimmer or non-dimmer mode: The dimmer/non-dimmer mode should be preset before the fixtures being connected to the devices. Please refer to “Dimmer/Switch Mode Setting” in this manual. Current Loading Precaution: To prolong the life of the device, we suggest you refer to the following instruction. 1.
Guarantee Lite-Puter promises to fulfill the following acceptances: 1. Lite-Puter is only responsible for EDX-607 dimmer pack itself. 2. Lite-Puter guarantees to keep Lite-Puter’s fault products caused by techniques, materials and any other logical reasons in good repair for free within a year since the distributing date.
Page 25
ISO 9001 CERTIFIED www.liteputer.com.tw World HeadquarterF Lite-Puter Enterprise Co., Ltd. Address: 11F, N0. 189, Gangqian Rd., Neihu Dist., Taipei City 11448, Taiwan. Tel: +886-2-27998099 Fax: +886-2-27993828 Website: www.liteputer.com.tw E-mail: sales@liteputer.com.tw Shanghai FactoryF Lite-Puter TechnologyFShanghaiFCo.,Ltd. Address:Building B5, No. 298, Lane 3509, Hongmei S. Road, Shanghai, China Zip Code:201108 Tel: +86-21-54408210 Fax: +86-21-64978079...