Lennox 16L23 Installation Instructions Manual

Lennox international inc. furnace transition kit installation instructions

Advertisement

Quick Links

_
Techrlloal
GAS UNITS
j
_:_bic=lo.s
KITS AND ACCESSORIES
Litho U,S.A,
©1997 Lennox
industries
inc.
Datlas, Texas
503,770M
10/97
FURNACE TRANSITION
KIT
INSTALLATION
INSTRUCTIONS
FOR FURNACE
TRANSITION
KIT CAT# 16L23
(LB-89657A),
CAT# 16L24 (LB-89657B),
AND CAT# 16L25 (LB-89658A),USED
WHEN
CONVERTING
FROM G14 UNITS TO G26 UNITS
(UPFLOW)
Package 1 of 1 contains:
1 - Supply airtransition
1 - External Filter rack (used with kit CAT# 16L23 and
16L24)
1 -
Internal filter rack top piece (used with kit CAT#
16L25)
1 -
Internal
filter
rack bottom
piece (used with
kit
CAT# 16L25)
1 -
Filter rack door
1 -
Roll of adhesive-backed
foam tape (1/8" thick x
5/16" wide)
8-
Insulation
pins
8-
Insulation
washers
1 -
1/2" CPVC x 1/2"PVC bushing
2 - Wire ties (used with kit CAT# 16L25)
Check all components
for shipping
damage. Consult
last carrier immediately
if damage is found.
Table 1 shows furnace transition
kit usage. These kits
are used when
replacing
an existing
G14 upflow
furnace
with
a G26
upflow
furnace.
It allows
installation
of the G26 furnace without
modification
of the existing
supply
and side return air plenums.
Bottom
return
air applications
do not require
the
provided
filter rack,
G14 installations
with air conditionh_g - G 14 removal
may
require
raising
of coil,
or partially
or fully
removing
the coil. If coil needs to be removed,
line
sets may need to be cut, which in turn requires system
pump-down
or refrigerant
recovery
depending
on
type of service valves provided
on condensing
unit or
ambient
outdoor temperatures.
Refer to figure
1 for typical G14 installation.
A - G14 units without air conditioning
1 - Set the thermostat
to the lowest setting,
2 - Disconnect
electrical
power to G14 unit,
3-
Shut off gas to G14 unit.
4 - Disconnect
supply air plenum at unit top.
5 - Remove control access panel,
6 - Cut combustion
air intake pipe and exhaust pipe
in
location(s)
which
will
allow
convenient
reconnection
of
pipes
to
G26
unit,
and/or
removal
of
muffler(s)
(if
installed).
Remove
muffler(s)
(if
installed),
Support
intake
and
exhaust
pipes to prevent damage to pipe joints,
7 - Cut condensate
drain line in a location which will
allow convenient
reconnection
with G26 unit.
8 - Disconnect
gas line at unit.
9 -
Disconnect
power wiring
at unit.
10 -Disconnect
low voltage wiring
at unit.
11 -Remove
blower
access panel.
TABLE 1
G14
CABINET WIDTH
G26
CABINET WIDTH
KIT CAT# (LB#)
inches (mm)
inches (mm)
Q3-40
21-1/4 (540)
Q2/Q3-50
16-1/4 (413)
16L23 (LB-89657A)
Q3-60
21-1/4 (540)
Q3-50 or Q3-75
16-1/4 (413)
16L23 (LB-89657A)
Q4-60
21-1/4 (540)
Q4/5-75
21-1/4 (540)
16L25 (LB-89658A)
Q3-80
21-1/4 (540)
Q3-75
16-1/4 (413)
16L23 (LB-89657A)
Q4-80
21-1/4 (540)
Q4/5-75
21-1/4 (540)
16L25 (LB-89658A
Q5-80
26-1/4 (667)
Q4/5-75
21-1/4 (540)
16L24 (LB-89657B)
Q3-100
26-1/4 (667)
Q3/4-100
21-1/4 (540)
16L24 (LB-89657B)
Q4/5-t00
26-1/4 (667)
Q4/5-100
21-1/4 (540)
16L24 (LB-89657B)
Page 1

Advertisement

loading

Summary of Contents for Lennox 16L23

  • Page 1 INSTRUCTIONS (LB-89657A), CAT# 16L24 (LB-89657B), CONVERTING Package 1 of 1 contains: 1 - Supply airtransition 1 - External Filter rack (used with kit CAT# 16L23 and 16L24) Internal filter rack top piece (used with kit CAT# 16L25) Internal filter rack bottom...
  • Page 2 12- Remove filter from insideof unit (if present). Units with side return air - Disconnect return air plenum at unit. Units with bottom return air - Disconnect base from return air plenum. 13 -Remove G14 unit, B - 614 units with air conditioning IMPORTANT 1 - Set the thermostat to the lowest setting.
  • Page 3 A - Filter Rack Installation (Side Return Only) Note - Filter rack is not used in bottom applications. with these I - External Filter Rack (Used with kit CAT#16L23 and16L24) instructions 1 - Lay G26 unit on its side and cut out return opening depth is 2-3/8"...
  • Page 4 See G26 5 - Connect high voltage installation inside unit as Connect side installations installation around. Consult installation restrictions on G26 furnace. 7 - Connect venting hole. Attach with instructions. Note installation. damage to (diameter specifications instructions.
  • Page 5 180 degrees and secure to top of frame. See detail B. as in detail C. FIGURE 2 (KIT CAT# 16L23 AND 16L24) Left Side Orientation Shown NOTE - THIS CONVERSION IS ALSO RECOMMENDED IF FILTERIS NOT INSTALLED IN RACK, BUT IS LOCATED ELSEWHEREIN RETURN AIR DUCT.
  • Page 6 INSTALLATION OF SUPPLY AIR TRANSITION AND EXTERNAL FILTER RACK (KIT CAT# 161.23 AND 16L24) ADHESIVE-BACKED FOAM TAPE FILTER RACK DOOR THUMB SCREW -_. _;_ CUT OPENING IN FILTER RACK AS FOLLOWS: Note - In 16 inch (40.6 cm) filter applications, 1 - Measure horizontally from rear of G14 to existing Mark vertical bend line.
  • Page 7 INSTALLATION OF SUPPLY AIR TRANSITION SUPPLY AIR TRANSITION SECURING SCREWS (2 each side) SUPPLY AIR TRANSITION ADHESIVE-BACKED FOAM TAPE "D" HOLES (Left side installation holes) "C" HOLES (Right side installation holes FILTER RACK TOP "FILTER RACK BOTTOM "FILTER RACK DOOR THUMB SCREW AND INTERNAL FILTER RACK (KIT CAT# 16L25)
  • Page 8 1/2 INCH CPVC VENT TERMINATION MUST BE HIGHER THAN COIL LEFT SIDE OF CABINET G26 CONDENSATE ASSEMBLY (For left or right installation - left shown) HEAT EXCHANGER COIL COMBUSTION BLOWER BRACKET 1/2"PVC X 1/2"MPT 1/2" PVC X 1/2" CPVC BUSHING (Bushing fits in one direction adapter...