Vive Comfort TP-S-855C Installation Manual

Vive Comfort TP-S-855C Installation Manual

Hide thumbs Also See for TP-S-855C:

Advertisement

C O M F O R T
TP-S-855C
VIVE Comfort
1111 S. Glenstone Ave., Suite 2-100
Spring eld, MO 65804
Toll-Free: 1-800-776-1635 Web: www.vivecomfort.com
Hours of Operation: M-F 9AM - 6PM Eastern
Thermostat Applications Guide
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (with Aux. or Emergency Heat)
Multi-stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Table of Contents

Patents and Trademarks pending.
Copyright © 2013. All rights reserved.
TM
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page
2
3
4
5-6
7
8-11
12-15
16
INSTALLATION MANUAL
5:23
PM
Power Type
Battery Power
Hardwire (Common Wire)
Hardwire (Common Wire) with Battery Backup
A trained, experienced technician
must install this product.
Carefully read these instructions. You
could damage this product or cause a
hazardous condition if you fail to follow
these instructions.
Una versión en español de este
manual se puede descargar en la
página web de la compañía.
Tue
F
Menu
O
Auto
Rev. 1413
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TP-S-855C and is the answer not in the manual?

Questions and answers

Summary of Contents for Vive Comfort TP-S-855C

  • Page 1: Table Of Contents

    INSTALLATION MANUAL C O M F O R T TP-S-855C 5:23 VIVE Comfort 1111 S. Glenstone Ave., Suite 2-100 Spring eld, MO 65804 Menu Auto Toll-Free: 1-800-776-1635 Web: www.vivecomfort.com Hours of Operation: M-F 9AM - 6PM Eastern Power Type Thermostat Applications Guide...
  • Page 2: Installation Tips

    INSTALLATION TIPS Wall Locations The thermostat should be installed approximately 4 to 5 feet above the oor. Select an area with average temperature and good air circulation. Do not install thermostat in locations: • Close to hot or cold air ducts •...
  • Page 3: Themostat Quick Reference

    THERMOSTAT QUICK REFERENCE Getting to know your thermostat Getting to know your thermostat Indicates the current room Displays the user Getting to know your thermostat temperature. selectable setpoint Days of the temperature. week and time Hold is displayed when Displays the user Hold is displayed when Indicates the 5:23...
  • Page 4: Subbase Installation

    SUBBASE INSTALLATION Caution Caution: Mercury Notice: Electrical Hazard All of our thermostats are mercury free. However, if the Failure to disconnect the product you are replacing power before beginning to contains mercury, dispose of it install this product can cause properly.
  • Page 5: Wiring

    WIRING Power supply Factory-installed jumper. Remove only when installing on 2-transformer systems Use either O or B terminals for changeover valve Optional 24 VAC common connection when thermostat is hardwired with battery backup mode. Typical 2H/2C system: 1 transformer Typical 2H/2C system: 2 transformer REMOVE JUMPER L1 (HOT) L1 (HOT)
  • Page 6: Terminal Designations

    WIRING Replacement Thermostat Wiring Warning If you are replacing a thermostat, make note All components of the control of the terminal connections on the thermo- system and the thermostat stat that is being replaced. In some cases the installation must conform to wiring connections will not be color-coded.
  • Page 7: Mounting And Battery Installation

    MOUNT THERMOSTAT & BATTERY INSTALLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place. 5:23 To insure a solid fit between the Note: thermostat and the subbase: Mount subbase to a flat wall...
  • Page 8: Technician Setup Menu

    TECHNICIAN SETUP MENU Technician Setup Menu Con gure the installer options as desired, This thermostat has a technician setup menu using the table below. for easy installer con guration. To setup the Use the keys to thermostat for your particular application: change settings and the NEXT Press MENU button.
  • Page 9 TECHNICIAN SETUP MENU Tech Setup Steps (Continued from the previous page) Heating Cooling Morning ºF or ºC 12 or 24 Program Time Periods Temperature Temperature Operation Recovery Hour Clock Options Setpoint Limit Setpoint Limit Select GAS for This feature will start You can con gure this This feature allows This feature allows...
  • Page 10 TECHNICIAN SETUP MENU Tech Setup Steps (Continued from the previous page) System Contractor Heat Pump Gas Auxiliary Beep Display Pre Occupancy Stages of Heat Call Number for Heat Pump Light The display light can This option will turn The pre occupancy Allows you to put When any key is When turned on...
  • Page 11 TECHNICIAN SETUP MENU Tech Setup Steps (Continued from the previous page) Humidity Pad UV Lamp Cooling Fan IAQ Cell Staging Delay Satisfy Setpoint IAQ Mode Cycle IAQ Mode Minutes Reminder Reminder Reminder Delay The cooling fan This feature will This allows you to This feature allows a This will remind the Will remind the user...
  • Page 12: Set Time

    PROGRAMMING Set Time Follow the steps below to set the day of the week and current time: Press MENU Press SET TIME Day of the week will be flashing. Use the key to select the current day of the week. Press NEXT The current hour is flashing.
  • Page 13 PROGRAMMING Occupied Unoccupied Occupied Unoccupied Occupied Unoccupied Wake / OCC 1 Leave / UNOCC 1 Return / OCC 2 Sleep / UNOCC 2 Occupied Unoccupied Wake / OCC 1 Leave / UNOCC 1 Return / OCC 2 Sleep / UNOCC 2 Occupied Unoccupied Wake / OCC 1...
  • Page 14 PROGRAMMING Set Program Schedule For Four Time Periods (WAKE, LEAVE, RETURN, SLEEP or OCCUPIED 1, UNOCCUPIED 1, OCCUPIED 2, UNOCCUPIED 2) Repeat steps 4 through 7 for Saturday WAKE/OCC1 time period, Press SET SCHED Note: Monday-Friday is displayed and the for Saturday LEAVE/UNOCC1 time WAKE/OCC1 icon is shown.
  • Page 15 PROGRAMMING Sunday time If you want to use IAQ mode during this time period, select IAQ with the fan key. If you want to use IAQ mode during this time period, select IAQ with the fan key.
  • Page 16: Speci Cations

    FEATURES & SPECIFICATIONS Filter Change and other Reminders Temporary and Permanent Hold Feature If your installing contractor has configured Temporary hold: The thermostat will display the thermostat to remind you when the air HOLD and RUN SCHED on the bottom filter needs changed, you will see FILT of your screen when you press the display when your air filter needs changed.

This manual is also suitable for:

S-855c series

Table of Contents