  • Page 1 SILFAB ONTARIO INC. SAFETY and INSTALLATION MANUAL Photovoltaic Modules: SLAXXXM3A/SLAXXXM, SLAXXXP3A/SLAXXXP, SLGXXXM3G/SLGXXXM, SLGXXXP3G/SLGXXXP Document Number: MAN-SFO-02 Revision Date: April 2, 2013...
  • Page 2: Table Of Contents

    à d’autres sources lumineuses. Tout contact avec des éléments sous tension du panneau tels que ses bornes de sortie peut entraîner des blessures ou la mort, que le panneau soit connecté ou non. © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 3: General Information

    Voltage at point of maximum power (Vp • Current at point of maximum power (Ip • Solar radiation in W/m at the time • Temperature of the cells © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 4: Disclaimer Of Liability

    Standard Test Conditions (STC) of 1000 W/m irradiance, with Air Mass (AM) of 1.5 spectrum, and a cell temperature of 25°C. © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 5: Safety Precautions

    Do not install or handle the modules when they shield them from exposure to light are wet or during periods of high winds. © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 6 Making connections with modules tilted perpendicular to the sun, to increase shading between the strings thus decreasing solar irradiance. © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 7: Installation

    Each module must be securely fastened at between them. This is necessary in order a minimum of 4 points. to maintain a correct load distribution (Fig. © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 8 – refer also to Fig. 5a/5b. Fig. 3b: Mechanical drawing of an SLG module showing the mounting holes, the drainage holes, and the ground connection holes © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 9 Fig. 4c: modules attached to supporting structure – side view. Fig. 4d: end of module row with additional spacer (item 05: 50mm x 30mm x 24mm) © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 10 © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 11 Bypass diodes are not series, when measured at their poles, is over-current protection devices. the sum of all the individual voltages of © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 12 • Ensure that the grounding area for the connection is clean and free from oxides or © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 13: Use And Maintenance

    500 W/m , a module exposed to the in W/m the short circuit current of the © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 14 As a result, the Voc of the module may damage. © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 15: Packaging, Handling And Storage Of Modules

    • Transparent film for containment recommended to store the pallet in a place that is sheltered and dry. In addition, as the the junction © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 16 Avoid scratching the surface of the on a surface that is either flat or not excessively deformed to a point that would impart an © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 17 Fig. 11 & 12: How to package the pallets and plastic corners, respectively, after unloading, ready to deliver back to Silfab for reuse. Fig. 10: Pallet sheet © 2011-2013 Silfab Ontario Inc. - Specifications in this manual are subject to revisions without notice...
  • Page 18: Appendix 1 - Electrical Specifications

    SAFETY AND INSTALLATION MANUAL FOR PHOTOVOLTAIC MODULES 10. APPENDIX 1 – Electrical Specifications SLA250M SLA255M SLA260M SLA265M SLA270M SLA275M SLA280M SLA285M Pmax 30.4 30.6 30.8 31.2 31.4 31.7 8.27 8.38 8.49 8.71 8.86 8.91 37.4 37.6 37.8 38.2 38.4 38.7 39.1 8.92 9.04...
  • Page 19 To download a copy of this installation manual scan the QR-Code on the back of a Silfab module, or go to: www.silfab.ca/media-center/download-area.html Silfab Ontario 240 Courtneypark Drive East, Mississauga, Ontario, Canada L5T 2Y3 - Tel: +1 905 255 2501 - Fax: +1 905 696 0267 - Email: info@silfab.ca...