Axeon Water Technologies L1-Series User Manual

Axeon Water Technologies L1-Series User Manual

Membrane system

Advertisement

Membrane System
User's Manual
L1-Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L1-Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Axeon Water Technologies L1-Series

  • Page 1 Membrane System User’s Manual L1-Series...
  • Page 2 This Page Left Blank L1-Series User’s Manual MKTF-258 9/14...
  • Page 3: Table Of Contents

    OPERATION LOG ............................ 22 SYSTEM DRAWING ..........................23 L1-200 SERIES FLOW DIAGRAM ......................24 L1 - SERIES ELECTRICAL SCHEMATIC 110V/60HZ .................. 24 L1 - SERIES ELECTRICAL SCHEMATIC 220V/50HZ .................. 26 REVERSE OSMOSIS SYSTEM WARRANTY ....................27 L1-Series User’s Manual MKTF-258 9/14...
  • Page 4: Introduction

    UNDERSTOOD. KEEP THIS AND OTHER ASSOCIATED INFORMATION FOR FUTURE REFERENCE AND FOR NEW OPERATORS OR QUALIFIED FUTURE REFERENCE AND FOR NEW OPERATORS OR QUALIFIED FUTURE REFERENCE AND FOR NEW OPERATORS OR QUALIFIED PERSONNEL NEAR THE SYSTEM. PERSONNEL NEAR THE SYSTEM. L1-Series User’s Manual MKTF-258 9/14...
  • Page 5: Safety

    ENT MUST BE SUFFICIENT TO ELIMINATE CHEMICALS, ORGANICS OR INORGA , ORGANICS OR INORGANICS THAT COULD COULD ATTACK THE MEMBRAN NE MATERIAL. • ALWAYS TURN RN OFF THE UNIT, SHUT OFF THE FEED W WATER, AND L1-Series User’s Manual MKTF-258 9/14...
  • Page 6: Feed Water And Operation Specifications

    2 - 12 **If any of the feed water parameters are not within the limits given, consult your local dealer or distributor for assistance. NOTE: HIGHER TDS AND/OR LOWER TEMPERATURES WILL REDUCE THE SYSTEM’S PRODUCTION. L1-Series User’s Manual MKTF-258 9/14...
  • Page 7: Rejection, Recovery And Flow Rates

    % Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100 Example: 28% = (0.14/0.50) x 100 NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS, TYPICALLY GALLONS PER MINUTE (GPM). L1-Series User’s Manual MKTF-258 9/14...
  • Page 8: System Installation And Start-Up Procedures

    30 seconds every time it starts up and once every hour when the system is producing water. NOTE: THE TANK PRESSURE SWITCH WILL SHUT THE SYSTEM OFF AUTOMATICALLY WHEN THE BLADDER TANK IS FULL. L1-Series User’s Manual MKTF-258 9/14...
  • Page 9 9. This system has been factory wired and preset with a pressure switch at 20 - 40 psi, which is only to be used with a pressurized bladder tank. If using an atmospheric storage tank, a float switch will be required to turn the system on and off. L1-Series User’s Manual MKTF-258 9/14...
  • Page 10: Membrane Elements

    MEMBRANE ELEMENTS L1 - Series Reverse Osmosis Systems equipped with Thin Film Composite (TFC) HF4 Extra Low Energy membranes, unless otherwise specified. General membrane element performance characteristics are listed below. HF4 – Extra Low Energy Membranes L1-Series User’s Manual MKTF-258 9/14...
  • Page 11: System Identification

    SYSTEM IDENTIFICATION L1-Series User’s Manual MKTF-258 9/14...
  • Page 12: Membrane Installation, Removal And Replacement

    5. Flow directions should be observed for installation of the membrane element into the pressure vessels. REPLACING THE MEMBRANE ELEMENT: WARNING: THE BRINE SEAL MUST BE IN THE SAME POSITION AS IT WAS FOR FACTORY PRE-INSTALLED MEMBRANE ELEMENT. THE BRINE SEAL IS A L1-Series User’s Manual MKTF-258 9/14...
  • Page 13 MINUTES TO REMOVE THE PRESERVATIVE FROM THE MEMBRANE. DISCARD ALL OF THE PERMEATE, WHICH IS PRODUCED DURING THE SCARD ALL OF THE PERMEATE, WHICH IS PRODUCED DURING THE SCARD ALL OF THE PERMEATE, WHICH IS PRODUCED DURING THE FLUSH PERIOD. L1-Series User’s Manual MKTF-258 9/14...
  • Page 14: Operation Do's And Don'ts

    • Always feed the pump with filtered water DON’T • Permit chlorine to enter membrane housing with the feed water • Shut down the system for extended periods • Operate the system with insufficient feed flow • Operate the pump dry L1-Series User’s Manual MKTF-258 9/14...
  • Page 15: Specifications

    SPECIFICATIONS L1-Series User’s Manual MKTF-258 9/14...
  • Page 16: Operation And Maintenance

    6. Keep the feed water temperature above 4° C (36° F). NOTE: EXTREMELY COLD FEED WATER WILL LOWER THE PRODUCT WATER OUTPUT AND INCREASE PUMP PRESSURE. L1-Series User’s Manual MKTF-258 9/14...
  • Page 17: Preparing Unit For Storage Or Shipment

    6. Disconnect the tubing from the connectors on the permeate and concentrate inlets and outlets. Allow the system to drain for a minimum of eight hours or until the opened ports quit dripping. After draining is complete, reconnect all of the plumbing. L1-Series User’s Manual MKTF-258 9/14...
  • Page 18: Reverse Osmosis Troubleshooting

    Activated Carbon or other pretreatment. Organic Fouling Clean with high pH cleaner. Check Chlorine feed equipment and de- Chlorine Oxidation chlorination system. Improve pretreatment. Check all filters Abrasion of membrane by Crystalline for media leakage. Material L1-Series User’s Manual MKTF-258 9/14...
  • Page 19 77° F. Check your permeate flow meter to determine the permeate flow rate. NOTE: TO DETERMINE THE TEMPERATURE CORRECTION FACTOR, LOCATE THE TEMPERATURE CORRECTION TABLE IN THIS USER’S MANUAL AND FOLLOW THE DIRECTIONS. L1-Series User’s Manual MKTF-258 9/14...
  • Page 20: Temperature Correction Factors For Membrane

    If a system is rated to produce 5 gpm of permeate water @ 77˚ F, the same system will produce more water at a higher temperature. It will also produce less water at a lower temperature. Use the temperature correction table to obtain the correct flow. L1-Series User’s Manual MKTF-258 9/14...
  • Page 21: Service Assistance

    Contact your local dealer or distributor. Prior to making the call, have the following information available: system installation date, serial number, daily log sheets, current operating parameters (e.g. flow, operating pressures, pH, etc.) and a detailed description of the problem. L1-Series User’s Manual MKTF-258 9/14...
  • Page 22: Operation Log

    FEED FLOW (GPM) PERMEATE FLOW (GPM) CONCENTRATE FLOW (GPM) RECOVERY % FEED TEMPERATURE FEED TDS (PPM) PERMEATE TDS (PPM) REJECTION % FEED PH PERMEATE PH SCALE INHIBITOR FEED (PPM) IRON (mg/L) FREE CHLORINE (mg/L) HARDNESS (GPG CaCO L1-Series User’s Manual MKTF-258 9/14...
  • Page 23: System Drawing

    SYSTEM DRAWING L1-Series User’s Manual MKTF-258 9/14...
  • Page 24: L1-200 Series Flow Diagram

    L1-300 FLOW DIAGRAM L1-Series User’s Manual MKTF-258 9/14...
  • Page 25 L1 - SERIES ELECTRICAL ELECTRICAL SCHEMATIC 110V/60HZ 110V/60HZ L1-Series User’s Manual MKTF-258 9/14...
  • Page 26: L1 - Series Electrical Schematic 220V/50Hz

    L1 - SERIES ELECTRICAL ELECTRICAL SCHEMATIC 220V/50HZ L1-Series User’s Manual MKTF-258 9/14...
  • Page 27: Reverse Osmosis System Warranty

    One-Year Limited Warranty Warranty Terms Subject to the terms and conditions set forth hereinafter, AXEON Water Technologies (hereafter “AXEON”) warrants to the original purchaser (hereafter the “Customer”) that the systems and products manufactured by AXEON are free from defects in...
  • Page 28 AXEON product shall be void and unenforceable unless the feed water requirements set forth in the operating documentation for such product are unequivocally and strictly adhered to. L1-Series User’s Manual MKTF-258 9/14...
  • Page 29 INCIDENTAL, ECONOMIC LOSS COMMERCIAL DAMAGE WHATSOEVER. REMEDIES HEREIN PROVIDED ARE EXPRESSLY MADE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF ANY WARRANTY OR OTHER OBLIGATION HEREUNDER EXPRESS OR IMPLIED OR FROM THE OPERATION OF LAW. L1-Series User’s Manual MKTF-258 9/14...