UNDERSTOOD. KEEP THIS AND OTHER ASSOCIATED INFORMATION FOR FUTURE REFERENCE AND FOR NEW OPERATORS OR QUALIFIED FUTURE REFERENCE AND FOR NEW OPERATORS OR QUALIFIED FUTURE REFERENCE AND FOR NEW OPERATORS OR QUALIFIED PERSONNEL NEAR THE SYSTEM. PERSONNEL NEAR THE SYSTEM. L1-Series User’s Manual MKTF-258 9/14...
ENT MUST BE SUFFICIENT TO ELIMINATE CHEMICALS, ORGANICS OR INORGA , ORGANICS OR INORGANICS THAT COULD COULD ATTACK THE MEMBRAN NE MATERIAL. • ALWAYS TURN RN OFF THE UNIT, SHUT OFF THE FEED W WATER, AND L1-Series User’s Manual MKTF-258 9/14...
2 - 12 **If any of the feed water parameters are not within the limits given, consult your local dealer or distributor for assistance. NOTE: HIGHER TDS AND/OR LOWER TEMPERATURES WILL REDUCE THE SYSTEM’S PRODUCTION. L1-Series User’s Manual MKTF-258 9/14...
% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100 Example: 28% = (0.14/0.50) x 100 NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS, TYPICALLY GALLONS PER MINUTE (GPM). L1-Series User’s Manual MKTF-258 9/14...
30 seconds every time it starts up and once every hour when the system is producing water. NOTE: THE TANK PRESSURE SWITCH WILL SHUT THE SYSTEM OFF AUTOMATICALLY WHEN THE BLADDER TANK IS FULL. L1-Series User’s Manual MKTF-258 9/14...
Page 9
9. This system has been factory wired and preset with a pressure switch at 20 - 40 psi, which is only to be used with a pressurized bladder tank. If using an atmospheric storage tank, a float switch will be required to turn the system on and off. L1-Series User’s Manual MKTF-258 9/14...
MEMBRANE ELEMENTS L1 - Series Reverse Osmosis Systems equipped with Thin Film Composite (TFC) HF4 Extra Low Energy membranes, unless otherwise specified. General membrane element performance characteristics are listed below. HF4 – Extra Low Energy Membranes L1-Series User’s Manual MKTF-258 9/14...
5. Flow directions should be observed for installation of the membrane element into the pressure vessels. REPLACING THE MEMBRANE ELEMENT: WARNING: THE BRINE SEAL MUST BE IN THE SAME POSITION AS IT WAS FOR FACTORY PRE-INSTALLED MEMBRANE ELEMENT. THE BRINE SEAL IS A L1-Series User’s Manual MKTF-258 9/14...
Page 13
MINUTES TO REMOVE THE PRESERVATIVE FROM THE MEMBRANE. DISCARD ALL OF THE PERMEATE, WHICH IS PRODUCED DURING THE SCARD ALL OF THE PERMEATE, WHICH IS PRODUCED DURING THE SCARD ALL OF THE PERMEATE, WHICH IS PRODUCED DURING THE FLUSH PERIOD. L1-Series User’s Manual MKTF-258 9/14...
• Always feed the pump with filtered water DON’T • Permit chlorine to enter membrane housing with the feed water • Shut down the system for extended periods • Operate the system with insufficient feed flow • Operate the pump dry L1-Series User’s Manual MKTF-258 9/14...
6. Keep the feed water temperature above 4° C (36° F). NOTE: EXTREMELY COLD FEED WATER WILL LOWER THE PRODUCT WATER OUTPUT AND INCREASE PUMP PRESSURE. L1-Series User’s Manual MKTF-258 9/14...
6. Disconnect the tubing from the connectors on the permeate and concentrate inlets and outlets. Allow the system to drain for a minimum of eight hours or until the opened ports quit dripping. After draining is complete, reconnect all of the plumbing. L1-Series User’s Manual MKTF-258 9/14...
Activated Carbon or other pretreatment. Organic Fouling Clean with high pH cleaner. Check Chlorine feed equipment and de- Chlorine Oxidation chlorination system. Improve pretreatment. Check all filters Abrasion of membrane by Crystalline for media leakage. Material L1-Series User’s Manual MKTF-258 9/14...
Page 19
77° F. Check your permeate flow meter to determine the permeate flow rate. NOTE: TO DETERMINE THE TEMPERATURE CORRECTION FACTOR, LOCATE THE TEMPERATURE CORRECTION TABLE IN THIS USER’S MANUAL AND FOLLOW THE DIRECTIONS. L1-Series User’s Manual MKTF-258 9/14...
If a system is rated to produce 5 gpm of permeate water @ 77˚ F, the same system will produce more water at a higher temperature. It will also produce less water at a lower temperature. Use the temperature correction table to obtain the correct flow. L1-Series User’s Manual MKTF-258 9/14...
Contact your local dealer or distributor. Prior to making the call, have the following information available: system installation date, serial number, daily log sheets, current operating parameters (e.g. flow, operating pressures, pH, etc.) and a detailed description of the problem. L1-Series User’s Manual MKTF-258 9/14...
One-Year Limited Warranty Warranty Terms Subject to the terms and conditions set forth hereinafter, AXEON Water Technologies (hereafter “AXEON”) warrants to the original purchaser (hereafter the “Customer”) that the systems and products manufactured by AXEON are free from defects in...
Page 28
AXEON product shall be void and unenforceable unless the feed water requirements set forth in the operating documentation for such product are unequivocally and strictly adhered to. L1-Series User’s Manual MKTF-258 9/14...
Page 29
INCIDENTAL, ECONOMIC LOSS COMMERCIAL DAMAGE WHATSOEVER. REMEDIES HEREIN PROVIDED ARE EXPRESSLY MADE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF ANY WARRANTY OR OTHER OBLIGATION HEREUNDER EXPRESS OR IMPLIED OR FROM THE OPERATION OF LAW. L1-Series User’s Manual MKTF-258 9/14...