Unit 30 & 31 New Hall Hey Business Park New Hall Hey Road, Rawtenstall, Rossendale, Lancashire BB4 6HR United Kingdom Tel: 00 44 (0)1706 229490 Fax: 00 44 (0)1706 830496 E-mail: Sales@jeisolutions.co.uk Web: www.jeiuk.com Operator’s manual for MAGBEAST 5 Drilling Machine...
Form habit of checking to see that keys and adjusting wrenches are removed from tool before turning it on. Avoid Unintentional Starting Do not carry plugged-in tool with fingers on switches. Be sure switches are off when plugging in. Operator’s manual for MAGBEAST 5 Drilling Machine - 2 -...
Page 3
Use only authorized service centres for repairs. Grounding Instructions Warning! READ ALL INSTRUCTIONS MAGBEAST 5 drilling machine must be connected to "protected power source" which is properly grounded. Improperly connecting the grounding wire can result in the risk of electrical shock.
Page 4
140 mm x 295 mm Magnetic deadlift (min 25mm plate thickness 2300 kg and 20°C) Vibration Level < 2,5 m/s List of Contents with Magnetic Drill Unit Wooden Box Magnetic Drill Unit Operators Mannual Operator’s manual for MAGBEAST 5 Drilling Machine...
Page 5
Control Panel Morsetaper 5 Powerful Magnet 2300kg deadlift. Adjustable (distance from the magnet to the Stabliser spindle can be adjusted) For easy handling and moving of the machine Operator’s manual for MAGBEAST 5 Drilling Machine...
Page 6
_____________________________________________________ Stopping & Starting the machine Variable Speed Control Operator’s manual for MAGBEAST 5 Drilling Machine...
Page 7
Use of Cutting Fluid 1 ¼” Weldon Shank Magbeast 5 has 5 Morse Taper spindle drilling. To be used with metal cutters, there is a necessity to use a 1.1/4’’ adapter. For this use the 1 1 / 4 ”Weldon shank is the most common.
Page 8
Once a Week Once a Month Visual check on machine for damage Operation of machine Check of magnetic base Check of brush wear Check Alignment of machine Check of grease Check armature Operator’s manual for MAGBEAST 5 Drilling Machine - 3 -...
Page 9
Some signs of wear will be seen on the commutator over a period of time. This is normal as this is the part that comes in contact with the brushes but any signs of abnormal damage and the part should be replaced. Operator’s manual for MAGBEAST 5 Drilling Machine - 4 -...
Page 10
MAGBEAST 5 Solutions for Drilling Problems Operator’s manual for MAGBEAST 5 Drilling Machine - 5 -...
Page 11
Contamination between spindle and bearing bracket Noise in the motor/gearbox Worn bearing between gearbox and motor Damaged drives in the gearbox Low amount of grease in the gearbox Operator’s manual for MAGBEAST 5 Drilling Machine - 6 -...
Page 12
Faulty magnet Fuse blows when starting the motor Damaged or defective wiring Defective armature and/or field Motors running too fast Worn brushes Defective control box Operator’s manual for MAGBEAST 5 Drilling Machine - 7 -...
Page 13
MAGBEAST 5 Magbeast 5 Parts diagram Operator’s manual for MAGBEAST 5 Drilling Machine - 8 -...
Page 17
MAGBEAST 5 JEI Six (6) month limited warranty JEI Solutions warrants the Magbeast 5 Drilling machine to be free of defects in material and workmanship under normal use for a period of six months from date of purchase. This warranty does not cover damage or wear which arise from misuse, accident, tampering or any other causes not related to defects in workmanship or materials.
Need help?
Do you have a question about the MAGBEAST 5 and is the answer not in the manual?
Questions and answers