Download Print this page
YORKVILLE AP 6040 Professional Series Service Manual
YORKVILLE AP 6040 Professional Series Service Manual

YORKVILLE AP 6040 Professional Series Service Manual

Hide thumbs Also See for AP 6040 Professional Series:

Advertisement

Quick Links

AP 6040
W E B AC C E SS: http://www.york ville.com
WORLD HEADQUARTERS
CANADA
U.S.A.
Yorkville Sound
Yorkville Sound Inc.
550 Granite Court
4625 Witmer Industrial Estate
Pickering, Ontario
Niagara Falls, New York
L1W-3Y8 CANADA
14305 USA
Voice: (905) 837-8481
Voice: (716) 297-2920
Fax: (905) 837-8746
Fax: (716) 297-3689
MODEL TYPE: YS6040
SERVICE MANUAL
Quality and Innovation Since 1963
Printed in Canada
Manual-Service-ap6040-00-2v3.pdf

Advertisement

loading
Need help?

Need help?

Do you have a question about the AP 6040 Professional Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YORKVILLE AP 6040 Professional Series

  • Page 1 AP 6040 W E B AC C E SS: http://www.york ville.com WORLD HEADQUARTERS CANADA U.S.A. Yorkville Sound Yorkville Sound Inc. 550 Granite Court 4625 Witmer Industrial Estate Pickering, Ontario Niagara Falls, New York L1W-3Y8 CANADA 14305 USA Voice: (905) 837-8481...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS This lightning flash with arrowhead symbol, within The exclamation point within an equilatereal triangle is an equilateral triangle, is intended to alert the user to intended to alert the user to the presence of important the presence of uninsulated “dangerous voltage” operating and maintenance (servicing) instructions in within the product’s enclosure that may be of sufficient the literature accompanying the appliance.
  • Page 3 6880 6880 4N35 4N35 U5:B U5:A 1/4W 1N753ARL 220R MINI R124A R125A D35A C33A C34A 1/8W 1/8W 100V 400V 100R0 MR854 220P 100V FLMP FLMP D37A IRF630NPBF BC550C Q32A 6752 BAV21 1/4W Q15A TO220 10K0 BC560C 5101 MINI R130A R182A TO92 C51A 5.0W...
  • Page 4 BlankSize - 18000x14000 M1150 A AP6040 Into Wave DISCONNECT POWER SUPPLY WIRES R104B WARNING R86B 10R0 BEFORE REMOVING BOARDS R87B 150R R92B 2N6517 C26B C27B Q27B R112B R120B C31B 100R0 R124B 330U 330U C24B 150R R114B R135B D22B 4148 BC550C R97B R134B C28B...
  • Page 5 BlankSize - 18000x14000 M1150 A AP6040 Into Wave R104B DISCONNECT POWER SUPPLY WIRES WARNING R86B 10R0 BEFORE REMOVING BOARDS R87B 150R R92B 2N6517 C26B C27B Q27B R120B R112B C31B 100R0 R124B 330U 330U C24B 150R R114B D22B 4148 R135B R97B R134B BC550C 6K98...
  • Page 6 SEE LAYOUT DIAGRAM M1150/M1150A - AP6040 M1182/M1182A - V64 PRODUCTION NOTES 1. MOUNTING DETAILS FOR 5W ADD #8629 SPACERS ONLY ON 4. MOUNTING HARDWARE FOR Q17B AND Q18B. 5 WATT RESISTORS R130, R131A, R130B AND R131A. ENSURE SPACERS ARE UNDER RESISTOR BODY ENOUGH TO RAISE IT OFF THE BOARD SURFACE.
  • Page 7 SEE LAYOUT DIAGRAM X8016.PCB_DATABASE_HISTORY MODEL(S):- AP6040 / V64 DATE VER# DESCRIPTION OF CHANGE MAY 12 1999 1.00 PILOT RUN RELEASE AUG 10 1999 2.00 PC#6043 RELAY CONNECTIONS ALTERED. ADD R30, IRF830 R50A/B R52A/B 10K0->4K99 R35C -R42C 20K0->10K0 MJ21195 PC#6042 CONNECT C50A FROM BASE OF Q24A TO COL MTP12P10 BD139 ADD J63 TO ELIMINATE SHORT TO MOUNTING SCREW...
  • Page 8 100N 100V 100N 100V W6:A 2 MC33078P U2:C 220P 100V U2:A W14:A W6:B 2 W14:B 1/4W 1/4W 1/4W W14:C 3922 100V 100V 1K54 9K76 9K76 0.1% 0.1% W14:D U2:B J3:A BC550C 150N 150N FAN2 1/4W MC33078P 5101 W11:A W1:A 8 TO92 W11:B W1:B 8...
  • Page 9 BANANNA JACKS MOUNTED ON CHASSIS Banana Jacks 3380 B OUTPUT A OUTPUT 3385 Banana Jacks Pcb Mech M1151 V9.0 BlankSize - 15000x10000 Top Assy M1151 V9.0 SPEAKON 4C H SPEAKON 4C H 3498 3498 6956 6956 3922 6517 6517 3922 STM-BTB-600BRG STM-BTB-600BRG TO220...
  • Page 10 SEE LAYOUT DIAGRAM M1151 PRODUCTION NOTES 1. MOUNTING DETAILS FOR TRIAC 6. PT# 3922 USE #8799 TO MOUNT TRIAC IMPORTANT AFTER MOUNTING DEVICE DO NOT CUT LEGS #2 OR #3 BEND LEGS IN DIRECTION SHOWN IT IS IMPERATIVE THAT LEGS MARKED 2 AND 3 ARE BENT FLAT AGAINST THE COPPER SURFACE BEND DOWN 1/4"...
  • Page 11 SEE LAYOUT DIAGRAM M1151 DRILL HISTORY M1151 MODEL(S):- MODEL(S):- AP6040 / V64 AP6040 / V64 DATE VER# DESCRIPTION OF CHANGE DATE VER# DESCRIPTION OF CHANGE AUG/10/99 2.00 PC#6034 LD2 ROTATED TRIACS Q18 Q22 DELETED. R85, Q17. C81 R84, R88,Q21, C83, R89 DELETED TRACES ENLARGED SEP/28/99 3.00...
  • Page 12: Service Bulletin

    All units should be modified as soon as possible. The units can either be returned to Yorkville for modification, or can easily be modified in the field by a qualified service technician. We will, of course, accept warranty claims for this modification.
  • Page 13 " 0 " PRODUCTION NOTES BLANK SIZE=18.000" X 13.900" MOUNTING DETAILS FOR 5W DISCONNECT POWER SUPPLY WIRES TP1B R104B WARNING R92B Q28B BEFORE REMOVING BOARDS ADD #8629 SPACERS ONLY ON R87B 150R 2N6517 R112B 5 WATT RESISTORS C20B R120B 220R BAV21 D37B C32B...
  • Page 14 CHANA_INPUT CHANB_INPUT #6956 #6956 CHANA_OUTPUT CHANB_OUTPUT TRIAC_MAC224 TRIAC_MAC224 SPEAKON SPEAKON CHANA_INPUT CHANB_INPUT SW3A #6444 #6444 PART# PART# PART# PART# TRIAC TRIAC BLACK C15 150N 150N C14 68N C23 100n SW4A WC33 SW2A SW1A C7 68N MBS4992 C16 68N V T R V T R C17 150N V T R...
  • Page 15 RE D +1 0 0 + 10 0 R E D...
  • Page 16 AP6040 Parts List 8/15/2012 YS # Description Qty. YS # Description Qty. YS # Description Qty. 6478 AS35FN-TO92 TEMPERATURE SENSOR 4520 _10K TRIM POT 6128 1/4W 4K99 1%MINI MF T&R RES 5906 RED 3MM LED 1V9 20MA.4SPCER T&R 2444 25.00 AMP CIRCUIT BREAKER 4978 1/4W 6K8 5%MINI T&R RES 5908 GRN...