CABIN 400
Operating manual

Advertisement

Table of Contents
loading

Summary of Contents for oxycom CABIN 400

  • Page 1 CABIN 400 Operating manual...
  • Page 2: Table Of Contents

    Switching on the CABIN 400 ........
  • Page 3: Introduction

    For daily use, see "Application and use" on page 8. If you do not intend to use the CABIN 400 for a period of four weeks or more, the system must be put into storage mode in order to prevent sediment and contaminant build-up in the water reservoir and the OXYCELL (heat exchangers) in the roof unit.
  • Page 4: Standards

    Failure to do so will invalidate the warranty. Standards The CABIN 400 meets all relevant technical standards and certification. The unit has been tested to EN 60335-1and EN 60335-2-40. The conformity tests were performed by TüV- Rheinland (Germany) and DARE Consultancy in Woerden (the Netherlands).
  • Page 5: System Construction And Function

    Y S T E M C O N S T R U C T I O N A N D F U N C T I O N Construction of the CABIN 400 ventilation and cooling system Figure 2.1 Schematic diagram showing the installed CABIN 400 system. The arrow indicates the direction of vehicle movement. •...
  • Page 6: Function

    - Optional: 2. float switch (11), which switches off the automatic water feed from the vehicle fresh water tank (12). Function To get the best out of your CABIN 400, it is important that you have a thorough understanding of the unit's function. We therefore recommend that you carefully read the following.
  • Page 7: Water Consumption

    The system is compact, light and does require much maintenance. • The system is environmentally friendly: - environmentally harmful cooling gases are not used; - all the materials used in the manufacture of the CABIN 400 can be recycled. 00010605 B...
  • Page 8: Application And Use

    230 Volt mains connection. Power supply when travelling When the CABIN 400 is used during the journey to the final destination, the electrical supply is provided by the 12 Volt battery via a static converter. Even though the unit consumes very little power, it should be noted that it can flatten the battery.
  • Page 9 Application and use Note When the vehicle is not in use, the static converter should be switched of at the main isolator. Otherwise the unit will continue to draw a small amount of power, which could flatten the batteries. Ventilation and cooling The operator panel on the OXYZONE is used to set the desired level of ventilation or cooling (see "Adjusting ventilation settings"...
  • Page 10: Switching On The Cabin 400

    Application and use First commissioning of the CABIN 400 Your dealer has installed the CABIN 400 with the greatest possible care. However it is recommended that you check that the water hoses running down to the water reservoir are free of kinks. (see "Figure 3.2").
  • Page 11: Adjusting Ventilation Settings

    Application and use activated. (If the CABIN 400 has been switched off for a long period, the cooling initialisation program will start up first.) Note As soon as the CABIN 400 is switched on, the function that was in use when the unit was switched off will be reactivated.
  • Page 12: Extra Water Feed For Use In Extremely Dry And/Or Hot Weather

    (A tone confirms that the setting has been successfully activated) Note When the CABIN 400 is next turned off, the water feed setting reverts to normal. The OXYCELL will then be moistened in the normal way. Controlling the air stream...
  • Page 13: Using The Cooling Function To The Best Effect

    Using an antibacterial additive (additive 2) Before using the CABIN 400 for the first time, or prior to starting the unit up after a long period of disuse, we recommend adding an antibacterial additive (additive 2) to the water as indicated on the packet.
  • Page 14: Filling The Water Reservoir

    See "Water quality" on page 24 ) Note The CABIN 400 has been constructed in such a way that no health risks will arise if contaminated water is inadvertently used. As the system does not produce a mist of fine droplets, there is no risk of infection by legionnaire's disease.
  • Page 15 5. Turn off the "insufficient water in the water reservoir" signal (if active) 6. (see illustration on the right: LED1 flashes) or the "drain and refill the water reservoir" signal (see the illustration below: LED4 flashes), by pressing the button. The CABIN 400 is now ready for use again. 00010605 B...
  • Page 16: Turning Off The Audible Warning Tone

    Turning off the audible warning tone The audible warning tone can be turned off by simultaneously pressing the buttons for 4 seconds. Note The audible tone will sound each time the CABIN 400 is turned on and off. 3.12 When it freezes Fully drain the water reservoir.
  • Page 17: The Meaning Of The Led Indicators

    The meaning of the LED indicators Table 1 The meaning of the LED indicators on the OXYZONE's operator panel LED signals Meaning The CABIN 400 is turned off. Ventilation Fan setting (in this example: setting 3). Cooling Cooling system start-up.
  • Page 18: Maintenance

    Clogged infeed vents or air filters will impede the air stream. Cleaning the infeed vents (roof unit) Figure 4.1 CABIN 400 roof units with infeed vents 1. Check that the infeed vents and gauze filters in the roof unit are free of insects and other debris.
  • Page 19 Maintenance Step 1: Removing the cover Figure 4.2 OXYZONE with air filter (B) and screen frame (C) 1. Push the screen frame towards the operator panel. Hold the frame securely to prevent it falling. 2. Slide the frame out of the OXYZONE. 00010605 B...
  • Page 20 Maintenance Step 2: Removing the filter for inspection 1. Release the two clips that retain the filter. 2. Check both sides of the filter. Install new filters if the existing filters are badly fouled. Step 3: Installing a new air filter 1.
  • Page 21: Cleaning The Water Pump Filter

    Maintenance Cleaning the water pump filter The function of the water pump filter The pumps in the water reservoir are fitted with a foam filter that envelops the pump. This filter has two functions: Sound absorption: The filter prevents contact noise between the pumps and the water reservoir obstructions: The filter catches particles in the Keeping the system free of...
  • Page 22: Storage Mode

    T O R A G E M O D E When The CABIN 400 should be set to storage mode, if you do not intend to use it for four weeks or more. The storage mode helps prevent chemical and bacteriological contamination of the water reservoir and the OXYCELL in the roof unit.
  • Page 23 Storage mode Figure 5.1 Storage mode process active (A). Storage mode process completed (B). Step 3: Draining the water reservoir Drain the water reservoir as indicated in "Step 1: Draining the water reservoir and checking the filter" on page 15. 00010605 B...
  • Page 24: Technical Specifications

    Water quality The CABIN 400 requires the use of drinking water only. The use of dirty water or water from pools or lakes is forbidden. If in doubt about water quality, ask the camping site manager or the local water authority if the water supply meets the following specifications.
  • Page 25: Functional Principles Of The Oxycell When Cooling

    Technical specifications Table 3 Water quality required for the CABIN 400 Parameter Max. value Unit Note Turbidity Iron content mg/l Colony count at 22ºC kve/ml Functional principles of the OXYCELL when cooling This section goes into more detail than the section entitled "Function" on page 6; it will be of interest to readers who wish to know more about the cooling principles used.
  • Page 26 R O U B L E S H O O T I N G The CABIN 400 is a robust system. Any problems that arise can most probably be attributed to reduced air throughput, insufficient water levels or problems with the water feed and return.
  • Page 27: Troubleshooting

    Troubleshooting Table 4 Problem solving Problem Check Possible cause Solution Ventilation Check the LEDs. If Air flow through the Check that the OXYZONE screen lit: OXYZONE is impeded. frame or exhaust vents are system does open. Check whether the air not work "Step 2: filters are blocked (see...
  • Page 28 Troubleshooting Table 4 Problem solving Problem Check Possible cause Solution System does Check water level. Water reservoir empty. Refill the water reservoir "Filling the water reservoir" not cool on page 14 The water reservoir is Close the drain cock and fill the "Filling the empty because the drain water reservoir.
  • Page 29 Troubleshooting Table 4 Problem solving Problem Check Possible cause Solution System neither The LEDs are lit, The fan does not work Refer the problem to your but: dealer for repair. cools nor Critical component or ventilates control system failure. 00010605 B...
  • Page 30: Accessories, Replacement Parts And Addresses

    A D D R E S S E S Replacement parts available from your dealer Table 5 CABIN 400 parts Part Description number 01870 OXYCELL( HEAT EXCHANGER) FOR THE CABIN 400 01524 FAN R2E250-AT06-18 10032 CABIN CIRCUIT BOARD 01545 OXYZONE EXHAUST COVER (ASSEMBLY) 00794 PUMP VIP-PLUS INCL.