Download Print this page

Radiant TH23F Operating Instructions

Forehead thermometer radiant th23f

Advertisement

Quick Links

TH23F Forehead Thermometer
Thank you for purchasing this Forehead thermometer. This thermometer is
designed with advance infrared and ambient temperature compensation
technology for accurate and fast temperature measurements.
It also has a wide range mode to scan real time temperature.
Do not use this device for Live & Dead decision or
Safety related applications. Please consult with doctor if you
have health concerns.
Operating Instructions:
1 Always make sure the probe lens is clean without any damage,
and the forehead is clean.
2 Power on: Press the "ON/MEM" button.
3 Mode selection:
3.1
FOREHEAD Mode: The preset mode of thermometer is forehead. The
thermometer is ready for use after the "HEAD" icon stops flashing and two beep sound.
3.2
SURFACE Mode: In "Power On" mode, press and hold the "ON/MEM" button, then press the "Meas." button, the '
replace "HEAD" icon in the LCD display.
4 Temperature taking:
Measuring the FOREHEAD temperature:
Figure 4.1
Figure 4.2
Figure 4.3
4.3
Press the "Meas." button, and gently scan around the temple area( Fig.4.3 ) , you can select the left side of the left temples or the
right side of the right temples. Measurement is completed after a long beep is heard. (The time of measurement might be
between 5~8sec (up to 30sec). That depends on how long the thermometer get the highest temperature of the forehead.)
4.4
Measuring temperature under SURFACE mode: When you press the "Meas." button, you will get the temperature immediately
about 0.6 sec. If you hold down the "Meas." button, the reading of measurement will be continuous updated. (Surface mode
shows the actual, unadjusted temperatures, which is different from the forehead mode.)
Note
C lassification according to IEC 60601-1
5 Switching between Celsius(°C) and Fahrenheit(°F):
To change the LCD from °C to °F: In "Power Off" mode, press and hold the "Meas." button, then press the "ON/MEM" button for 3
seconds, icon "°C" will be switched to icon "°F". You can also use the same process to change the LCD display from °F to °C.
6 Memory Function: Press the "ON/MEM" button to see the temperature stored. This thermometer provides 25 sets memory for the
measurements. ** Please notice that only the "HEAD" function's reading will be recorded. (After each measurement, the reading is
saved into memory.)
Device will automatically shut down after 1 minute pending to extend battery life.
7 Power off:
next power on, it will get back to the default setting of "HEAD" temperature function
Holding the thermometer too long may cause a higher ambient temperature reading of the probe.
This could make the body temperature measurement lower than usual.
Fever Alarm:
If the thermometer detects a temperature
3 7.5°C (or 99.5°F) under forehead mode, three short beep sound will follow one long beep
sound to warn the user for potential fever.
Specifications:
1 .
Comply with ASTM E1965-98, IEC60601-1, IEC60601-1-2(EMC) standards.
2. Temperature measurement range: Forehead mode 34~42.2°C (93.2~108°F), Surface mode: -22~80°C (-7.6~176°F)
3. Accuracy: Forehead mode: ±0.3°C(0.5°F)
Surface mode: ±0.3°C(0.5°F) within 22~42.2°C (71.6~108°F), others ±4% or ±2°C(4°F) whichever is greater.
o
o
4.Operating Range
1 0~40°C (50
F ~104
F), the relative humidity < 85%
5. ** Storage temperature range: It should be stored at room temperature between -20~+50°C, RH
Transportation temperature shall be less than 70°C, RH
There is no gender and age limitation for using infrared thermometer.
Note: Forehead temperature is displayed in Oral Mode. This thermometer
converts the forehead temperature to display its "Oral equivalent."
4.1
The temporal artery connect to heart via the carotid artery. Forehead
thermometer is designed to measure the skin surface over the temporal
artery, the major artery of the head ( Fig.4.1 ).
4.2
Attach the device to the required measurement location on the forehead
( Fig.4.2 ).
N ot classified as AP/APG equipment ; Continuous operation equipment.
At
8 5%
9 5%
This is not an AP or APG product.
Cleaning and Storage:
The Probe is the most delicate part of the thermometer.
Use with care when cleaning the probe to avoid damage.
a. Allow the lens to fully dry for at least 1 minute.
b. Keep the unit dry and away from any liquids and direct sunlight.
Please use the alcohol swab or the soft cotton moistened with the 70% alcohol to clean the probe lens.
c.
d. Clean the probe and probe lens after each use to ensure an accurate reading and avoid cross contamination.
Important Notes:
1. Make sure the Probe is clean and avoid the smothered with Rubber boat (Protector).
2. Before the measurement, please stay in a stable environment for 5mins and avoid the exercise, bath for 30minutes.
3. Remember to keep the temple area clean and away from sweat, cosmetics and scar while taking temperature.
4. During the measurement, please away from the direct sunshine and wind.
Changing the Battery:
It is supplied with one lithium cell (CR2032x1pcs)
O pen the battery compartment by turning the cover 45° clockwise with a coin.
object.
I nsert a new battery under the metal hook and press down until you hear a "click" sound
' icon will
Keep the battery away from children.
Troubleshooting:
Error Message
Problem
Device stabilization in process.
Battery is low and no more measurements are
possible.
The device showing a rapid ambient temperature
change.
The ambient temperature is not within the range
between 10°C and 40°C (50°F~104°F).
Error 5~9, the system is not functioning properly.
Temperature taken is higher than 42.2°C (108.0°F)
for forehead mode or 80°C (176°F) for surface
mode.
Temperature taken is lower than 34°C (93.2°F) for
forehead mode or –22°C (-7.6°F) for surface mode.
Device can not be powered on to the ready stage. Change with a new battery.
Warranty: 12 months
Manufacture Date
a s the serial number( please open the battery cover, it is shown on the inside of the device.)
Ex.SN:E912A000001, the first "E" is External, the second number "9" is the manufacture year 2009, the third and the fourth
number "12" is the manufacture month, the others is the serial number.
Note: The thermometer is calibrated at the time of manufacture. If at any time you question the accuracy of temperature
measurements, please contact the dealers or nearest service address.
Please read the instructions for use
Medical Technology Promedt Consulting GmbH
Add: Altenhofstrasse 80, D-66386 St. Ingbert, Germany
Radiant Innovation Inc. Tel: +886-3-5644185, Fax: +886-3-5644170, E-mail:mkt@radiantek.com.tw
Add: 1F, No.3, Industrial East 9
Note
T he information of manufactory is behind the device . (You can see it after removing the rubber protector)
** The thermometer is NOT
water-proof. Please keep the unit
dry and away from any liquids.
R emove the battery safety strip with a sharp-pointed
C lose the battery cover.
Disposal of the used batteries
: : : :
P lease comply with the local regulation.
Solution
Wait until
stops flashing.
Replace the battery.
Allow the thermometer to rest in a room for at least 30
minutes at room temperature: 10°C~40°C(50°F~104°F).
Allow the thermometer to rest in a room at least 30 minutes
at room temperature: 10°C~40°C(50°F~104°F).
Unload the battery, wait for 1 minute and repower it. If the
message reappears, contact the retailer for service.
1) For forehead mode, please stay in a stable environment
for 5mins and avoid the exercise and bath for 30min, then
make sure the probe lens is clean before take a new
temperature measurement.
2) For surface mode, please select target within
specifications.
If a mal-function still exists, please contact the nearest
retailer.
BF type applied part
th
Rd., Science-Based Industrial Park, HsinChu, Taiwan Http://www.radiantek.com.tw
Ref No.
0 82012

Advertisement

loading

Summary of Contents for Radiant TH23F

  • Page 1 1 0~40°C (50 F ~104 F), the relative humidity < 85% Radiant Innovation Inc. Tel: +886-3-5644185, Fax: +886-3-5644170, E-mail:mkt@radiantek.com.tw Add: 1F, No.3, Industrial East 9 Rd., Science-Based Industrial Park, HsinChu, Taiwan Http://www.radiantek.com.tw 5. ** Storage temperature range: It should be stored at room temperature between -20~+50°C, RH ≦...
  • Page 2 Symbol Descriptions Guidance and manufacturer’s declaration – electromagnetic immunity The CE mark and Indicates this device is The TH2xyz series is intended for use in the electromagnetic environment specified below. The Notified Body subject to the Waste customer or the user of the TH2xyz series should assure that it is used in such an environment. Registration Electrical and Electronic 60601...
  • Page 3 Guidance and manufacturer’s declaration – electromagnetic immunity Recommended separation distances between portable and mobile RF communications equipment and the The TH2xyz series is intended for use in the electromagnetic environment specified below. The ME EQUIPMENT or ME SYSTEM customer or the user of the TH2xyz series should assure that it is used in such an environment. The TH2xyz series is intended for use in an electromagnetic environment in which radiated RF IEC 60601 test Compliance...