Bench top fume extractor fan with task light and sh237 wet dry tip cleaner (4 pages)
Summary of Contents for Edsyn FUMINATOR FXF15
Page 1
Instructions FXF15 FUMINATOR Fume Extractor Fan Color Power Supply FXF15 Standard (Black) (U.S.A.) FXF15W (White) (No Transformer) FXF15B -100 (Blue) (Japan) -230 (Europe) -230B (U.K.) Create a healthy environment Form.996 (Design, colors and materials subject to change without notice) Rev D...
FXF15 exploded view FXF10-1 SR638 PowerSupply SR642* SR868* SR480 SR867 SR640* SR639 SR866 (washer placed between fan and post) XF02 XF01 Primary Rotating Filter Filter Set The XF02 filter element rotates at the same speed as the fan blades. Fumes and nail resi- dues are evenly distributed.
Page 3
exploded view 1. XF03 Charcoal Impregnated Stationary Filter 2. SR489 Cage 3. SR474 Fan Motor 4. XF02 Primary Rotating Filter 5. SR475 Circuit Board Assembly Items 2, 3 & 5 are Serviced at the Factory Filter Replacement 1. Pull out dirty filter from hub when fan is off.
Need help?
Do you have a question about the FUMINATOR FXF15 and is the answer not in the manual?