Ras-24Ukp-Es-1 / Ras-24Ua - Toshiba RAS-24UKHP-ES-1 Service Manual

Toshiba split wall type air conditioner service manual
Table of Contents

Advertisement

5-3. RAS-24UKP-ES-1 / RAS-24UA-ES-1
Cooling
0.49m
(Connecting pipe)
∅12.7
O.D.:12.7mm
P
Packed valve
(∅12.7)
Gas container connection (Reinstall etc.)
Cooling
Cooling Compressor
Tank
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Heat exchanger
Cross flow fan
PA290X3F-4MS
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T1 (°C)
0.9
0.8
0.5
– 18 –
FILE NO. SVM-03009
T1
Packed valve
(∅6.35)
Capillary tube
∅2.0x600s
Refrigerant
R410A 1.6kg
Mark(
)means check points of Gas Leak.
Fan speed
(indoor)
11.0
High
12.0
High
1.0
Low
0.39m
(Connecting pipe)
∅6.35
O.D.:6.35mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15