OPERATION INSTRUCTIONS FOR THE
DUCTSTAT
TEMPERATURE SENSITIVE SWITCH
®
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT NOTICE
With the use of any electrical appliance, it is important to observe all basic precautions to
minimize the risk associated with use, such as electrical shock, fire, or injury to persons.
Read these instructions before using your DuctStat® Temperature Sensitive Switch™.
If you have doubts or are unfamiliar with this type of installation work, seek the services of
a qualified electrician.
Suncourt Inc. assumes no responsibility for installation of the DuctStat®.
For your safety and protection, follow all instructions and adhere to applicable building
and/or electrical codes.
This unit is equipped with a three prong grounded plug. Do NOT attempt to defeat this
feature of this plug. Defeating this will void the warranty.
Do not use in an attic or crawlspace.
NEVER EXPOSE YOUR DUCTSTAT TO TEMPERATURES OVER 140°F (60°C)
INSTALLATION NOTES
In order to prevent excessive stress on the mounting screws, support the DuctStat® when
unplugging connected devices.
Do NOT use the DuctStat® outdoors or in damp locations. The DuctStat® must remain
accessible.
The DuctStat® is intended to control the automatic On/Off operation of In-Line Duct Fans™
installed in the ductwork of forced air distribution systems.
The DuctStat® can also control the line voltage to any electrical device with a maximum current
draw of 5 Amperes.
The DuctStat® is equipped with an external, replaceable 5 AMP fuse to protect the electronic
circuitry from overload or short circuits.
This device is designed to turn on and off from temperature rise and fall. The DuctStat®
will turn on in HEAT mode when it senses temperature rise. The DuctStat® will turn on in
COOL mode when it senses temperature fall.
INSTALLATION INSTRUCTIONS
1. Locate the position between the In-Line Duct Fan™ and the register where you wish to
mount the DuctStat®. Mount between 1 and 10 feet downstream from the In-Line Duct Fan™.
2. Tape the template supplied with the DuctStat® to the air duct to mark the mounting holes to
be drilled.
3. Drill a hole in the air duct for the Air Intake Hole shown on the template. This hole should
be 1/2" in diameter.
Function switch selections:
Function switch selections:
OFF: to stop operation of the device.
OFF: to stop operation of the device.
ON: for continuous running of device.
ON: for continuous running of device.
HEAT: for automatic on with temperature rise.
HEAT: for automatic on with temperature rise.
COOL: for automatic on with temperature drop.
COOL: for automatic on with temperature drop.
The rotary knob selects the automatic on/off
The rotary knob selects the automatic on/off
temperature setting for heating or cooling.
temperature setting for heating or cooling.
The Differential switch provides control over on/off
The Differential switch provides control over on/off
cycling.
cycling.
Posiciones de función del interruptor:
Posiciones de función del interruptor:
OFF: para desactivar el dispositivo.
OFF: para desactivar el dispositivo.
ON: para activar el dispostivo.
ON: para activar el dispostivo.
HEAT: para activar automática con elevación de la temperature.
HEAT: para activar automática con elevación de la temperature.
COOL: para activar automática con desciende de la temperature.
COOL: para activar automática con desciende de la temperature.
El perilla rotatorio controla la automática encendido y apagado para
El perilla rotatorio controla la automática encendido y apagado para
enfriamiento y calefacción.
enfriamiento y calefacción.
El "DIFFERENTIAL" controla la frecuencia del dispositivo de encendido
El "DIFFERENTIAL" controla la frecuencia del dispositivo de encendido
y apagado.
y apagado.
Commutateur de function positionne:
Commutateur de function positionne:
OFF: Arret du dispositive.
OFF: Arret du dispositive.
ON: Fonctionnement continu du dispositive.
ON: Fonctionnement continu du dispositive.
HEAT: Pour le démarrage automatique lorsque la température s'élève
HEAT: Pour le démarrage automatique lorsque la température s'élève
COOL: Pour le démarrage automatique lorsque la temperature descend.
COOL: Pour le démarrage automatique lorsque la temperature descend.
Le bouton rotatif fixe la marche / arrêt automatique pour chauffage ou
Le bouton rotatif fixe la marche / arrêt automatique pour chauffage ou
refroidissement.
refroidissement.
Le "Differential" permet un contrôle pour marche / arrêt le cyclisme.
Le "Differential" permet un contrôle pour marche / arrêt le cyclisme.
4. Drill holes in the air duct to line up with the appropriate holes located on the template. On
round ducts, two screws placed through the slots in the DuctStat®'s base will be adequate
(placement shown on template). On square or rectangular ducts use four screws, one at each
corner of the DuctStat® (placement shown on template).
5. Tighten the supplied screws snugly in the appropriate placement for your ductwork. DO
NOT OVER TIGHTEN
6. Plug the device into the outlet on the face of the DuctStat®.
MODEL: DS100
7. Plug the DuctStat® power cord into a 120 VAC grounded household outlet.
8. Follow Operation Settings to adjust the DuctStat®.
Function switch selections:
OFF to stop operation of the device.
ON for continuous running of device.
HEAT for automatic on with temperature rise.
COOL for automatic on with temperature drop.
The rotary knob selects the automatic on/off temperature setting
for heating or cooling.
The Differential switch provides control over on/off cycling.
OPERATION SETTINGS
When switch is on "HEAT" the DuctStat® will turn ON as the temperature rises.
1. Perform Operation Settings in the environment in which the DuctStat® is being used. For
use with forced air systems, make sure the blower is not running.
2. Plug in the DuctStat® and set the switch to OFF.
3. Set the Differential to 3°.
4. Plug the device you want to control into the DuctStat®.
5. Turn the knob clockwise until it stops. DO NOT FORCE.
6. Move the switch to ON. You should see/hear the device that is plugged into the DuctStat®
turn on.
7. Turn the switch to HEAT. At this point the device plugged into the DuctStat® will turn off.
8. Slowly turn the knob counterclockwise, just until the device plugged into the DuctStat® turns
ON.
9. Slowly turn the knob clockwise, just until the device plugged into the DuctStat® turns OFF.
10. The DuctStat® is now set to turn on when the temperature rises. If you would like the
DuctStat® to have a wider range, simply switch the Differential to 7°. This will turn the device
on and off with a larger on/off differential.
FOR HEATING
Position the Function switch
to HEAT.
(Turns "ON" on temperature rise)
STEP 8
STEP 9
Turn clockwise until the
Turn counterclockwise
device turns off.
until the device turns on.
When the switch is on "COOL" the DuctStat® will turn ON as it senses cooler air
(temperature drop).
1. Perform Operation Settings in the environment in which the DuctStat® is being used. For use
with forced air systems, make sure the blower is not running.
2. Plug in the DuctStat® and set the switch to OFF.
3. Set the Differential to 3°.
4. Plug the device you want to control into the DuctStat®.
5. Turn the knob counterclockwise until it stops. DO NOT FORCE.
6. Move the switch to ON. You should see/hear the device that is plugged into the DuctStat® turn
on.
7. Turn the switch to COOL. At this point the device plugged into the DuctStat® will turn off.
8. Slowly turn the knob clockwise, until the device plugged into the DuctStat® turns ON.
9. Slowly turn the knob counterclockwise, until the device plugged into the DuctStat® turns OFF.
10. The DuctStat® is now set to turn on when the temperature drops. If you would like the
DuctStat® to have a wider range, simply switch the Differential to 7°. This will turn the device on
and off with a larger on/off differential.
FOR COOLING
STEP 8
Turn clockwise until
Position the Function switch
the device turns on.
to COOL.
(Turns "ON" on temperature drop)
IMPORTANT NOTE
To shorten the length of time that your device continues to run after the warming or cooling air has
shut off, rotate the knob control slightly further, as in Step 9.
Should you experience frequent On/Off cycling, move the Differential switch to the 7° position.
HEAT-COOL SETTING LOGIC
If you want the DuctStat® to turn a device on when the temperature rises above your set point you
put it on HEAT. If you want the DuctStat® to turn a device on when the temperature drops below
your set point you put it on COOL. The DuctStat® will deactivate when the temperature returns to
your set point.
If you have questions or comments, please call us at 1-800-999-3267 or send an email to
info@suncourt.com.
GARANTIE LIMITÉE D'UN AN
ONE YEAR LIMITED WARRANTY
Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the DuctStat
Sous réserve des limites suivantes, Suncourt Inc. (fabricant) garantit que le thermostat enfichable
Temperature Sensitive Switch™ will, for 1 (one) year from date of original retail purchase, but not
DuctStat® (Temperature Sensitive Switchtm) sera, pendant 1 (un) an à compter de la date d'achat
exceeding 2 (two) years from date of manufacture, remain free from appearance of defects in
d'origine, exempt de vice de matériau ou de main-d'œuvre. Cette garantie est assujettie aux limites
workmanship or materials. This warranty is subject to the following limitations: (a) manufacturer's
suivantes :
liability is limited to the replacement or repair of the DuctStat®, as decided by the manufacturer; (b)
(this is a numbered list)
1. La responsabilité du fabricant se limite au remplacement ou à la réparation du DuctStat®, à sa
a defective DuctStat® must be returned, prepaid, with proof of purchase, well packaged to avoid
damage in transit; and (c) this warranty does not apply to defects resulting from the alteration,
convenance.
2. Un DuctStat® défaillant doit être retourné, accompagné de la preuve d'achat et bien emballé
abuse, accidental damage, unauthorized repair, or misuse of the DuctStat®. This warranty is given
in lieu of all other warranties, guarantees, and conditions on manufacturer's part, and the manufac-
pour éviter des dommages durant le transport.
turer shall have no tortious or other liability in respect to this DuctStat
3. Cette garantie ne s'applique pas aux défauts résultant de l'altération, d'un abus, d'un dommage
Switch™. Ship unit to Suncourt Inc. only after obtaining a Return Goods Authorization (RGA)
accidentel, d'une réparation non autorisée ou d'une mauvaise utilisation du DuctStat®. Cette
number. Returns without this RGA number will not be accepted.
garantie remplace toute autre garantie et conditions de la part du fabricant, et le fabricant ne pourra
avoir d'autres responsabilités, de nature délictuelle ou autre, à l'égard du thermostat enfichable
DuctStat® (Temperature Sensitive Switchtm).
Actual product appearance may differ from illustrations.
Suncourt reserves the right to modify any or all of its products' features, designs, components and
REMARQUE : Le produit réel peut différer de celui présenté dans les illustrations.
specifications without notice.
Suncourt se réserve le droit de modifier un ou plusieurs des caractéristiques, des styles, des
SUNCOURT INC.
SUNCOURT INC.
P.O. Box 40
P.O. Box 40
Durant, IA 52747-0040
Durant, IA 52747-0040
1.800.999.FANS (3267)
1.800.999.FANS (3267)
www.suncourt.com
www.suncourt.com
STEP 9
Turn counterclockwise until
the device turns off.
®
®
Temperature Sensitive
WNT860-0711-C01
WNT860-0711-C01
PRINTED IN CHINA
IMPRIMÉ EN CHINE

Advertisement

loading
Need help?

Need help?

Do you have a question about the DUCTSTAT DS100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sun Court DUCTSTAT DS100

  • Page 1 OPERATION INSTRUCTIONS FOR THE 4. Drill holes in the air duct to line up with the appropriate holes located on the template. On When the switch is on “COOL” the DuctStat® will turn ON as it senses cooler air round ducts, two screws placed through the slots in the DuctStat®’s base will be adequate (temperature drop).
  • Page 2 Lorsque l’interrupteur est en mode « COOL » (refroidissement), le DuctStat® se mettra en fonction 4. Percez des trous dans le conduit d’air en vous assurant qu’ils sont alignés avec les orifices INSTRUCTIONS D’OPÉRATION POUR LE lorsqu’il détectera de l’air plus froid dans le réseau de gaines. (chute de température) appropriés du gabarit.