Whirlpool 6ADP 8540 IX Service Manual page 3

Table of Contents

Advertisement

S E R V I C E
Technical data
Flow rates/ Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)
Spray pump
Drain pump
Pump height max.
Inlet valve
Spray arm lower
Sprayarm upper
Shower top
Electrical base data
Voltage
Frequency
Total power
Fuse
Motor
Spray pump motor permanent spray system
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Power consumption
Resistance
Whirlpool Europe
Customer Service
208
lmp/l
45 - 65
l/min
16
l/min
1.1
m
4
l/min
~ 33
l/min
~ 27
l/min
~ 8
l/min
240
V
50
Hz
2.4
kW
10
A
220/ 240 V
145
W
69
48
µ F
4
220/ 240 V
30
W
146
6ADP 8540 IX
8542 540 53740
Heating (1 Element system)
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat
self reset
(Temperature of water)
Fuse
Water valves
Waterstop system
Single electric inlet valve
Voltage
Frequency
Resistance
Coil of dispenser
Voltage
Frequency
Resistance
Reed contacts
flow meter
rinse aid control
NTC
20 ˚C
25 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
Accesory
If you need spare parts apart from the spare
part list have a look in the
Service Bulletin 4812 718 40084.
08.08.2002 / Page 3
Doc. No: 4812 718 18226
240
V
2.22
kW
24.5
~ 2.0
˚C/min
~ 115
˚C
~ 85
˚C
206
˚C
Drip tray
220/ 240 V
50/ 60
Hz
3.76
kΩ
220/ 240 V
50/ 60
Hz
1.3
kΩ
58.1
kΩ
47 .1
kΩ
38.2
kΩ
25.4
kΩ
17 .2
kΩ
11.8
kΩ
8.3
kΩ
6
kΩ
4
kΩ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents