SPECIFICATIONS & GUIDELINES
1. OIL TYPE TABLE
Temp.
NON-DETERGENT
Straight Weight
Recommended
2. EXTENSION CORD TABLE
Extension Cord
Length
Up to 25 Ft.
25-50 Ft.
3.
The warranty on the motor will be NULL and VOID if a failure occurs and
inspection proves a current deficiency.
4.
The PRESSURE SWITCH and/or pilot unloader valve are set at factory for
maximum efficiency. DO NOT alter setting. Adjusting either will VOID
the warranty.
MODEL #
SERIAL #__________________
606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com
READ BEFORE OPERATION
IMPORTANT
0 - 32°
10 WT
Motor
½ and ¾ HP
Minimum Wire Size
14 Ga.
12 Ga.
5715K17, 6715K17,
6820K17
32° - 55°
55° & above
20 WT
30 WT
Motor
1, 1 ½ and 2 HP
Minimum Wire Size
12 Ga.
10 Ga.

Advertisement

loading
Need help?

Need help?

Do you have a question about the 5715K17 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rolair 5715K17

  • Page 1 The PRESSURE SWITCH and/or pilot unloader valve are set at factory for maximum efficiency. DO NOT alter setting. Adjusting either will VOID the warranty. MODEL # 5715K17, 6715K17, 6820K17 SERIAL #__________________ 606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com...
  • Page 2 CUSTOMER RESPONSIBILITIES To obtain the longest possible service life from your new compressor, adhere to the following operating instructions: Always operate the unit in a level position. All splash lubricated pumps have a dipper on the bottom of the connecting rod that must remain submerged in the oil bath to provide proper lubrication.
  • Page 3 If time test is considerably off, contact your local ROLAIR representative to arrange service. From 0 to ______*PSI From 0 to ______*PSI Date Date 606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com - 1 -...
  • Page 4 We are committed to continuing this tradition by analyzing and adapting to the changing needs and rigorous demands of your industry. You can depend on ROLAIR because they are built to last. This manual was compiled for the benefit of the operator. Do not use or allow anyone else to use your air compressor until this manual is read and all safety/operating instructions are understood.
  • Page 5: Safety Warnings

    WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. SAFETY WARNINGS READ AND UNDERSTAND ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR Hazard Level Potential of Hazard How to Avoid Hazard Serious injury or death may occur from Never inhale compressed air directly from the...
  • Page 6 SAFETY WARNINGS (con’t) Never operate the air compressor without Serious injury may occur from moving parts protective belt guards installed. Replace such as belts, pulleys, flywheels or fans if they damaged protective covers or guards came in contact with you or your clothing. immediately.
  • Page 7 SYSTEM CONTROLS (1) SAFETY RELIEF VALVE Every ROLAIR air compressor is equipped with a safety relief valve which is designed to discharge tank pressure at a predetermined setting when a systems failure occurs. Check the safety valve periodically by pulling on the ring only when the tank pressure is completely drained.
  • Page 8 (10) CHECK VALVE Every ROLAIR air compressor is built with a check valve to seal off and maintain tank pressure after the top end pressure setting of pilot valve or pressure switch is reached. The check valve works in conjunction with the pressure switch...
  • Page 9 PRE-START CHECKLIST Read the owner’s manual thoroughly. Make sure that you completely understand all of the safety warnings, system controls and instructions provided before attempting to operate this air compressor. Every effort has been made to provide you with the information needed to obtain many years of reliable and trouble-free service out of your new air compressor.
  • Page 10 – WARNING Your safety and the wellbeing of others during the operation of every ROLAIR compressor is our main concern. Do not operate or permit anyone else to operate your air compressor until the information contained in this manual is read and completely understood. Please contact your distributor or our customer service department if you have any questions on the proper use of your air compressor.
  • Page 11 NOTE: Unit must be level when in operation OIL TYPE TABLE Temperature 0-40° 40° & Above NON-DETERGENT – Straight Weight 10WT* 30WT* *For maximum performance and service life, we recommend using ROLAIR Premium Quality compressor oil. MAINTENANCE SCHEDULE Recommendation Daily Weekly Monthly Quarterly Check Oil Level...
  • Page 12 TORQUE CHART (INCH/LBS) Pump Type Direct Drive Head Bolts Cylinder Bolts Bearing Carrier Bolts Connecting Rod Bolts 121.5 121.5 121.5 121.5 121.5 121.5 Flywheel Determine pump type using suffix of Model number (Example: 4090HK17 uses K17 pump) PILOT VALVE ADJUSTMENT RESETTING DIFFERENTIAL (2) Make sure the top toggle lever is positioned as shown.
  • Page 13: Troubleshooting

    TROUBLESHOOTING WARNING Make sure you completely understand all of the safety warnings and operation of each system control component before attempting any maintenance or repair. Always drain the tank pressure completely, make sure the power cord is unplugged, and unit has time to cool before performing any maintenance or service operations.
  • Page 14 Our line covers the complete needs of today’s varied air requirements. Rely on ROLAIR for all the newest and finest features that are available for the modern compressor. 606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com 5/09...
  • Page 16 *Note: Nylon & Copper Tubing are sold by the foot; may be ordered in bulk lengths. **Order part #154D if unit is built with dual controls. 606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 9 9 20.349.3281 > fax 920.349.3691 > www.rolair.com 5/09...
  • Page 18 30502510CH Aftercooler 3290146ACH *BUSHING IS NOT MACHINED TO FIT PISTON PIN IF ORDERED SEPARATE FROM CONNECTING ROD. 606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 9 9 20.349.3281 > fax 920.349.3691 > > www.rolair.com 5/09...