13.6.2. OFF Timer Control
OFF timer can be set using remote control, the unit with timer set will stop operate at set time.

13.7. Auto Restart Control

• When the power supply is cut off during the operation of air conditioner, the compressor will re-operate between three to four
minutes (10 patterns to be selected randomly) after power resume.
• During multi split connection, Indoor unit will resume previous mode, include unit standby mode.

13.8. Indication Panel

Note:
• If POWER LED is blinking (0.5 seconds ON, 0.5 second OFF), the possible operation of the unit are during Indoor Residual Heat
Removal, Hot Start, during Deice operation, operation mode judgment, or ON timer sampling.
• If POWER LED is blinking (2.5 seconds ON, 0.5 second OFF), the unit is in standby mode.
• If TIMER LED is blinking, there is an abnormality operation occurs.
LED
Color
Light ON
Light OFF
Operation OFF
POWER
Green
Operation ON
40
TIMER
Orange
Timer Setting ON
Timer Setting OFF