Sanyo PLC-HF10000L Service Manual page 40

Multimedia projector
Hide thumbs Also See for PLC-HF10000L:
Table of Contents

Advertisement

Optical Parts Disassembly
1-1 Polarized glasses-out/pre-polarized glasses removal
Remove 1 screw-B (M2.5x4) on each stopper and take the polarized glasses
upward off.
Blue Marker
* When removing the outer Polarized
glass-(OUT/B)1, remove the inner
Polarized glass-(OUT/B)2 first.
Otherwise the edge of the holder
may scratch the surface of polar-
izged glass.
Mounting direction
Mount the pre-polarized glasses and polarized glasses as shown in the figure below.
Lcd panel/Prism top view
Red Marker
R-LCD panel
Green Marker
* Note on handling the polarized glasses
Polarized glass-(OUT/B) is very sensitive parts. Grab the edge of the
glass by new gloves when handling the polarized glass.
B
Polarized glass-(OUT/B)1*
Polarized glass-(OUT/B)2
(Blue)
Film side
Prism
Film side
G-LCD panel
-40-
B
(Green)
Polarized glass-
(OUT/G)1
Polarized glass-
(OUT/G)2
B
Film side
B-LCD panel
Blue Marker
Green Marker
Polarized
glass (OUT/R)
(red)
Pre-Polarized
glass (OUT/R)

Advertisement

Table of Contents
loading