Exposed nails or staples should be sealed with silicone sealant.
21.
Slide the reducing coupling down till it fits over the black pipe.
22.
Cut off the white 55mm pipe even with the top of the reducing coupling.
23.
Slide the insect netting down over the top of the reducing coupling. Secure it in place using a hose clamp.
24.
Plug the unit into a grounded 110VAC outlet.
25.
Wherever the ventilation pipe passes through an unconditioned area (i.e. attic space) it needs to be insulated.
Use a pipe wrap with an insulating value of at least R11.
A rain cap is not necessary. If one is desired, use ONLY the BioLet authorized wind directional cap (Part#
wind) that can be obtained from BioLet or your authorized dealer. Any other cap may hinder the airflow from
the toilet and cause a reduction in the performance of the unit.
Through the exterior wall using 2 – 45° elbows.
54mm 45° elbows (part# 820021) and 108mm outside pipe kits (part# 506) may be purchased from BioLet or your
authorized dealer.
Position the toilet against the wall.
1.
Mark the place on wall directly above the vent opening on the toilet where you want the pipe to pass through the
2.
wall (*** MUST BE AT LEAST 8" ABOVE THE TOILET ***).
Drill a 2 1/4" hole at a 45° angle through the wall where marked in the previous step.
3.
Cut the belled end off 1 length of 54mm white pipe.
4.
Insert the male stub of the 45° elbow into one end of the pipe you just cut in step 4.
5.
Pass the other end of the pipe/elbow assembly trough the hole you drilled in step 3.
6.
Measure the distance from the top of the vent pipe opening on the toilet to the end of the 45° elbow and add 2".
7.
Cut the belled end of the straight white pipe to achieve the length found in step 7. (you should now have a straight
8.
white pipe, non-belled)
Insert 1 length of 54mm, white, belled pipe into the rubber connector on the back of the toilet with the belled end
9.
up. (Pipe will only go ¼" to ½" into the rubber connector.)
Insert the next white, belled pipe into the pipe installed in the back of the toilet. Repeat until the end of the white
10.
pipe reaches the 45° elbow. (the last pipe in this assembly should be the pipe you cut in step 8)
Insert the male stub of the 45° elbow passing through the wall into the end of the pipe explained in step 10.
11.
Outside the structure cut the pipe sticking through the wall so only 2" of pipe are protruding.
12.
Insert the male stub of the 2nd 45° elbow into the pipe protruding through the wall.
13.
Insert the other male stub of the 45° elbow into the non-belled end of a 54mm white pipe.
14.
Wrap the pipe in step 14 in insulation and tape the seams using duct tape.
15.
Slide the non-belled 108mm black pipe over the insulated pipe in step 15.
16.
Continue the pipe upward as in the "Straight run through ceiling and roof" procedures above insulating each pipe
17.
as in steps 15 & 16 in this procedure. The remaining 108mm black pipes should be assembled with the belled end
down.

Starting the toilet

Add approximately 3 quarts of water to the 8 gallon bag of starter mulch. Mix thoroughly. (This is only to keep the
1.
mulch from dusting)
Open the compost cover by pressing on the toilet seat.
2.
Add 2 gallons of the 8 gallon bag of starter mulch into the toilet.
3.
Turn the mixer handle several times in the clockwise direction (10 Standard) or press and hold the micro switch
4.
behind the seat (20 Deluxe), until the mixer stops (approx 5 seconds). Then release the button and allowing the
mixing arms to complete their cycle between each press (approx 1 minute). Repeat 2 – 3 times until the mulch is
evenly disbursed through the toilet.
Add another 2 gallons of starter mulch to the toilet.
5.
Turn the mixer handle several times in the clockwise direction (10 Standard) or Press and hold the micro switch
6.
behind the seat (20 Deluxe), until the mixer stops (approx 5 seconds). Then release the button and allowing the
mixing arms to complete their cycle between each press (approx 1 minute). Repeat 2 – 3 times until the mulch is
evenly disbursed through the toilet.
A majority or all of the mulch will fall through the grate and into the tray. THIS IS NORMAL - DO NOT EMPTY THE