  • Page 1 TECHNOLOGIEN MIT VORSPRUNG is Pro DP/PA Link DTM User Manual...
  • Page 2 Copyright © ifak system GmbH 2004, all rights reserved. No part of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or storage in an information retrieval system - without prior written permission of the ifak system GmbH.
  • Page 3: Table Of Contents

    ......10 Chapter 3: Gateway DTM is Pro DP/PA Link DTM Configuration in Offline Mode .
  • Page 4 Pro DP/PA Link DTM ifak system GmbH...
  • Page 5: Chapter 1: Introduction

    Pro DP/PA Link DTM Software Installation H A P T E R NTRODUCTION The GatewayDTM allows the integration is Pro DP/PA Link DTM of a Siemens Profibus DP/PA Link device into any FDT Engi- neering and Configuration Tool (PACTware, FieldCare or other FDT Containers).
  • Page 6: Documentation

    Introduction is Pro DP/PA Link DTM Documentation This documentation contains important information for the cor- rect operation of the . Please read this is Pro DP/PA Link DTM documentation carefully before installing the software. Throughout the manual different fonts are used to indicate differ- ent meanings.
  • Page 7: Chapter 2: Fdt - A Brief Introduction

    FDT. For a seamless integration of all components FDT specifies (with more or less depth) the object model, interfaces and XML schemas, as well as a session and data management. ifak system GmbH...
  • Page 8: Object Model

    The ActiveX fits seamlessly into the Frame Application. The user is not able to determine where the called HMI came from. It appears as a natu- ral part of the engineering system. ifak system GmbH...
  • Page 9 CommDTM or by the Frame Application. DeviceDTM and CommDTM differ mainly in the type of chan- nels a DTM supports. A Channel represents either a communica- tion (CommChannel) or data channel (DataChannel). A ifak system GmbH...
  • Page 10 If a DeviceDTM is called and attached to a certain device, this DeviceDTM instance is associated with a CommChannel. The device can establish a connection to the device through this Com- mChannel. Contrary to today’s practice the DeviceDTM can expect an interface with a manufacturer independent behaviour. ifak system GmbH...
  • Page 11: Component Interaction

    The run-time environment (the frame application) was started already. In the next step we add a CommDTM to the system topology of the frame application. The frame is now able to inquire the CommDTM about the supported CommChannels. ifak system GmbH...
  • Page 12 The communication between both components is now estab- lished. If the DeviceDTM invokes a communication request via IFdt- Communication the channel is responsible for the handling of the request. The response of the device is transmitted to the DTM through its IFdtCommunicationEvents interface. ifak system GmbH...
  • Page 13: Summary: Objects In The Fdt Concept

    ) communication interface. The Comm- is HART OPC Server DTM itself can employ the services of another CommDTM (gateway functionality). To allow communication with its under- lying hardware or software the CommDTM offers a number of communication (Comm) channels. ifak system GmbH...
  • Page 14: Commchannel

    DeviceDTM into the topology of the Com- mChannel. It also contains functions, which allow the Device- DTM to check whether it is able to communicate with this channel (e.g. information about the supported fieldbus protocol). ifak system GmbH...
  • Page 15 Pro DP/PA Link DTM H A P T E R DP/PA L ATEWAY Following is a description of the configuration of the Gateway . The Gateway DTM can be inte- is Pro DP/PA Link DTM grated into any frame application e. g. Pactware. First one has to install the software (see chapter 1).
  • Page 16: Chapter 3: Gateway Dtm Is Pro Dp/Pa Link Dtm

    Gateway DTM is Pro DP/PA Link DTM is Pro DP/PA Link DTM Configuration in Offline Mode Change DeviceDTM Address This ActiveX allows to change tag and address of connected DeviceDTMs. This is possible only in the offline mode, because otherwise existing connections could be disconnected.
  • Page 17: Configuration In Online Mode

    Pro DP/PA Link DTM Configuration in Online Mode Configuration in Online Mode The FDT specification defines the function ) for ScanRequest( CommDTMs. This function makes it possible to receive a list of devices that are connected to the bus (also called "live list").
  • Page 18 Gateway DTM is Pro DP/PA Link DTM is Pro DP/PA Link DTM Figure 6: Device List (online) An ActiveX with additional information about a device can be opened by selecting the button "Extended Information..." for a chosen slave device. The button "Change Address..." opens another ActiveX for changing the address of the Profibus device.
  • Page 19: Slave Information

    Pro DP/PA Link DTM Configuration in Online Mode Slave Information The information in this ActiveX are obtained from the diagnosis data of the selected Profibus slave device. Their meaning is explained in the Profibus literature. The device and vendor names are extracted from tables that con- tain such information for a number of devices identified by the identification number (Ident).
  • Page 20: Change Slave Address

    Gateway DTM is Pro DP/PA Link DTM is Pro DP/PA Link DTM Change Slave Address This ActiveX offers an interface to change the address of a Profi- bus slave device. The current address is set automatically when the ActiveX is opened. The new address is not allowed to be in use at the same Profibus segment.