A.H. Systems Model PAM-0118P Pre-Amplifier INTRODUCTION The PAM-0118P broadband preamplifier is an excellent choice for improving system dynamic range. The performance of this preamplifier will increase your system sensitivity by at least 35 dB and is ideal for low-amplitude test measurements.
HAZARDOUS RF VOLTAGES The PAM-0118P preamplifier is reliable when operated under specified conditions; however the use of sensitive, high-performance semiconductors causes the preamplifier to be susceptible to ESD and EOS. The risk of damage due to ESD is small, but possible, because the charged object would have to come in contact with one of the center conductors.
Storage near strong EMI or RFI fields Loose connections causing intermittent events An over voltage at the preamp input will damage the preamplifier. This type of damage is without fault of A.H. Systems and will void the warranty. To connect: 1. Apply DC Voltage 2.
OPERATING INSTRUCTIONS Operation of the Model PAM-0118P preamplifier is quite simple. The unit is turned on by first plugging the phone-type plug from an external power supply into the power input connector. The power supply is then plugged into the appropriate line voltage supply.
Size (W x H x D)...........3.75" x 2.5" x 6.25” INCLUDED EQUIPMENT The Model PAM-0118P preamplifier is supplied with an external regulated power supply, that can be used on 110 – 120 Vac, 60 Hz or 220 – 240 Vac, 50 Hz, and supplies +15 Vdc up to 1 A.
A.H. Systems Model PAM-0118P Pre-Amplifier TYPICAL DATA The following is typical data of the Model PAM-0118P preamplifier: A.H. Systems inc. – May 2014 REV D...
For Immunity measurements, the generated electric field strength can be calculated by: FS = Approximate Field Strength in (V/m) P = Power in watts g = Numeric Gain d = Distance in meters A.H. Systems inc. – May 2014 REV D...
Page 10
The derivation for the constant in the above equation comes from the decibel equivalent of the factor of 1000 used to convert W to mW and vice versa, as shown below. A.H. Systems inc. – May 2014 REV D...
Page 11
Converting from T to pT and from A/m to A/m, and deriving the Log, the constant becomes: 240 - 120 + 20Log [4 x 10 ] = 2.0 dBpT = dBV + dBpT/V + Cable Loss dBV/m = dBpT + 49.5 dB A.H. Systems inc. – May 2014 REV D...
A.H. Systems Model PAM-0118P Pre-Amplifier MAINTENANCE The Model PAM-0118P preamplifier requires virtually no maintenance as long as the unit is not exposed to moisture, or extreme temperatures. But as with any electrical device ESD and EOS is always a concern.
A.H. Systems Model PAM-0118P Pre-Amplifier WARRANTY INFORMATION A.H. Systems Inc. warrants that our Antennas, Sensors and Probes will be free from defects in materials and workmanship for a period of three (3) years. All other products delivered under contract will be warranted for a period of two (2) years. Damage caused by excessive signals at the product's input is not covered under the warranty.