Novatek NACF75 Operating Instructions Manual

Novaclean automatic water filters

Advertisement

Novaclean Automatic
Water Filters
Operation Manual
ACF Activated Carbon Filter, MMF Multimedia Filter, NF Neutralizing Filter
Page 5 of this manual contains important maintenance procedures required for the continued
proper operation of this unit. These MUST be performed regularly for your guarantee to
remain valid.
51876 Rev. 11/08

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NACF75 and is the answer not in the manual?

Questions and answers

Summary of Contents for Novatek NACF75

  • Page 1 Novaclean Automatic Water Filters Operation Manual ACF Activated Carbon Filter, MMF Multimedia Filter, NF Neutralizing Filter Page 5 of this manual contains important maintenance procedures required for the continued proper operation of this unit. These MUST be performed regularly for your guarantee to remain valid.
  • Page 2 Cu Ft Service Peak Backwash Inches - W x D x H Size - Inches Weight - Lbs NACF75 10 x 10 x 57 8 x 47 NACF10 12 x 12 x 57 10 x 47 NACF15 14 x 14 x 62...
  • Page 3: Installation Instructions

    Installation and Start-up Procedure Installation Instructions CAUTION: If the ground from the electrical panel or breaker box to the water meter or underground copper Electrical Panel pipe is tied to the copper water lines and these Ground Strap lines are cut during installation of the Noryl Copper Pipe bypass valve and/or poly pipe, an approved grounding strap must be used between the two...
  • Page 4: Operating Instructions

    Operating Instructions How Your Automatic Filter Works Raw water enters your home through the main supply line, enters your filter, and passes downward through the media bed. Impurities such as turbidity and sediment (MMF) and organics (ACF) are removed from the water. The filtered water then flows up and into your household water lines.
  • Page 5 Programming Backwash Controls Setting The 24-Hour Timer Press and hold the red button in to disengage the drive gear. Turn the large dial until the actual time of day is opposite the time of day pointer. Release the red button to re-engage the drive gear. Determining The Backwash Frequency The following table can be used to help determine the frequency of regeneration.
  • Page 6: Maintenance Instructions

    Maintenance Instructions Maintenance of your new water filter requires very little time or effort but it is essential. Regular maintenance will ensure many years of efficient and trouble free operation. Care of All Water Filters To retain the attractive appearance of your new water filter, clean occasionally with a mild soap solution. Do not use abrasive cleaners, ammonia or solvents.
  • Page 7: Trouble Shooting Guide

    Trouble Shooting Guide PROBLEM CAUSE CORRECTION 1. Filter bleeds taste and odor or Bypass valve is open Close bypass valve. sediment Electrical service to unit has been Assure permanent electrical service (check fuse, interrupted plug or switch). Defective or stripped media bed Replace media.
  • Page 8 Seven Year Complete Parts Guarantee: Novatek will replace any part which fails within 84 months from date of manufacture, as indicated by the serial number provided the failure is due to a defect in material or workmanship. The only exception shall be when proof of purchase or installation is provided and then the warranty period shall be from the date thereof.