adpos micro PC Series User Manual

Internal type

Advertisement

9. SPECIFICATION:
Internal UPS
Micro PC 300
CAPACITY
(Computer Load)
INPUT
Voltage
100V/110V/115V/220V/230V/240V ± 15%
Frequency
50Hz/60Hz Auto detect
100V/110V/115V/220V/230V/240V ±5%
OUTPUT
Voltage
Frequency
50Hz or 60Hz ± 0.1Hz
Wave Form
Simulated Pseudo Sine Wave
Runtime of one set of P.C.
10 minutes Typical.
(Including 15" LCD monitor)
TRANSFER TIME
4ms Typical.
BATTERY
Voltage/Capacity
Recharge Time
Approx. 8 hrs to 90%
LED/ALARM INDICATION
Normal/
GRN LED, No Beep.
In charge
RED LED Flashing, 2 Beeps / 4 sec.
Back up / Abnormal Input Voltage
Power Saving
RED LED Flashing,1 Beep / 4 sec.
(When No Load)
Low Battery
RED LED Flashing, 4 Beeps / sec.
Battery Replacement
RED LED Flashing, 8 Beeps/ sec.
Over Load/Fault
RED LED Flashing, Continuous Beep.
RED LED Flashing, No Beep.
Abnormal Input Frequency
(Back up)
OPERATION TEMP.
0-40℃
OPERATION HUMIDITY
30-95% Non-Condensing
DIMENSIONS (L*H*W)
242 x 144 x 40(mm)
WEIGHT
(N.W./G.W. KG)
Micro PC series
MODEL
Micro PC 600
(Hi Frequency)
300VA / 180W
400VA / 240W
for Back-up Mode
30 minutes Typical.
Maintenance Free
Lead-Acid
Ni-MH
6V 3Ah x 2pcs
1.2V 3.5Ah x 15pcs
Approx. 21 hrs to 90%
(Auto off in 30 sec.)
242 x 144 x 40(mm)
3 .5/ 3.5 (kgs)
3.5 / 4.0 (kgs)
7
U P S
Uninterruptible Power System
User's Manual
INTERNAL TYPE
(Micro PC series)
Advanced Power Systems GmbH & Co. KG, Bayreuther Str. 6, D-91301 Forchheim
Phone: +49(0)9191-7005-0, Fax: +49(0)9191-7005-20, www.adpos-ups.de
Micro PC series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the micro PC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for adpos micro PC Series

  • Page 1 242 x 144 x 40(mm) 242 x 144 x 40(mm) WEIGHT 3 .5/ 3.5 (kgs) 3.5 / 4.0 (kgs) (N.W./G.W. KG) Advanced Power Systems GmbH & Co. KG, Bayreuther Str. 6, D-91301 Forchheim Phone: +49(0)9191-7005-0, Fax: +49(0)9191-7005-20, www.adpos-ups.de Micro PC series Micro PC series...
  • Page 2 BUTTON FUNCTION ON FRONT PANEL button Pushing when in normal mode ------- Self test Pushing when in backup mode ------- Alarm reset (silence) Pushing for 4 sec. in any mode ------- Power off manually Micro PC series Micro PC series...
  • Page 3 UPS must be charged for at least 12 hours before your first use. Please simply turn on the UPS after installation when city power is normal, and the batteries will be charged automatically. M icro PC series Micro PC series...
  • Page 4 However, if the frequency of city power is abnormal, outside the range 47 – 65Hz, the UPS will switch to backup mode for protecting your computer. (Even the city power voltage is O.K.) Micro PC series Micro PC series...

Table of Contents