3.8.8. Charging
Charging block in ABB processes charging operation by using VBAT, ICHG value through ADC
channel. Battery Block Indication and SPEC of L1100 is as follow.
4.2V~3.92V
1. Charging method: CC-CV
2. Charger detect voltage: about 5.2V
3. Charging time: 3h under
4. Icon stop current: 100mA
5. Charging current: 420mA
6. CV voltage: 4.2V
7. Cutoff current: 30mA
8. Full charge indication current (icon stop current) : 100mA
9. Recharge voltage: 4.16V
10. Low battery alarm
a. Idle: 3.62V
b. Dedicated: 3.50V
11. Low battery alarm interval :
a. Idle: 3min
b. Dedicated:1min
12. Switch-off voltage: 3.35V
13. Charging temperature ADC range
a. ~ -5℃ : not charging operation.
b. -5℃ ~ 50℃ : charging.
c. 50℃~ : not charging operation.
Figure 15. Battery Block Indication
3.91V~3.79V
3.78V~3.70V
3.69V~3.61V
-32-
3.60V~3.35V