Contents HML-ISO_35_ Rev01122009_E.doc Contents ABOUT THESE INSTRUCTIONS ..........4 1.1 Symbols and guidance signs in these instructions ......4 1.2 Who are these instructions for? ............4 SAFETY ..................5 2.1 General information ................ 5 2.2 How to handle halogen lamps ............5 2.3 Safety devices .................
These instructions are intended for the personnel, that are assigned with the assembly or operation and maintenance of a WISKA searchlight Type HML-ISO 35 or one of its versions. Risk of electric shock! All electrical installation and repair work may only be carried out by...
Safety HML-ISO_35_ Rev01122009_E.doc 2. Safety The following safety instructions have to be strictly followed! Otherwise you put yourself and others in danger. 2.1 General information Intended use The HML-ISO 35 searchlight is designed for sending light signals. The range (1 lux at target) of the searchlight is 300 m. It is developed specially for use on ocean-going vessels and for safety applications on the coast.
Safety HML-ISO_35_ Rev01122009_E.doc 2.3 Safety devices Radiation / escape of dangerous particles If the halogen lamp explodes during operation, the casing remains intact and contains any heated glass splinters. Overload protection Electrical means of overload protection, such as fuses have to be provided by the customer. Refer to chapter 3.2 Technical Specifications regarding the power of the unit.
An overview of the unit HML-ISO_35_ Rev01122009_E.doc 3.4 Circuit diagram HML-ISO 35 with PowerPack HML-ISO 35 HML-ISO 35 with fixed connection (12V DC-24V DC) on a concentric socket (WISKA Type DK 503) Cabling HML-ISO 35 internal VOTAGE CONVERTER CONTROL BOARD SAP.NR. 50100464...
Check the delivery. Do not start the unit if there is transport damage or missing parts! Contact WISKA or our sales partner in your country. The address can be found at the back of these instructions or on the internet under www.wiska.de.
Operation HML-ISO_35_ Rev01122009_E.doc Operation Signalling Pressing the signal button (1) lights the searchlight, so that pressing and releasing of the button sends light signals. Torch function Pressing the signal button (1) and the function button (2) activates the torch mode. When doing so the lamp lights until one of either buttons is pressed.
Maintenance / Replacement of detective parts HML-ISO_35_ Rev01122009_E.doc Maintenance 6.1 Cleaning Clean the front glass on the outside as needed. Cleaning the inside of the searchlight is not necessary. 6.2 Charging the BatteryPack ISO 35 Warning! Explosive gases are generated when charging lead batteries. Please ensure adequate ventilation and avoid fire or naked light.
3. Reinsert the front glass and close the quick releases. 4. Dispose of the defective halogen lamp properly. Disposal Electrical components contain substances which are hazardous for the environment. Ensure proper disposal or send the defect parts to WISKA. The address is on the back page of these instructions.
Concentric socket DK 503 30070639 PowerPack ISO 35 30100354 Charger, HML-ISO 35 30100356 Front glass, blue HML-ISO 35 50100468 Front glass, green HML-ISO 35 50100467 Front glass, red HML-ISO 35 50100469 All other parts can be obtained by contacting WISKA sales.
Need help?
Do you have a question about the HML - ISO 35 and is the answer not in the manual?
Questions and answers