Evm Measurements; Pcs Mode Handset Commands; Tx Frequency Error Measurement Test - Motorola TDMA M3090 Service Manual

Digital wireless telephone
Table of Contents

Advertisement

Test Procedures

EVM Measurements

EVM Measurements
Figure 38. Digital Measurements Screen
DIGITAL MEASUREMENTS
DTC Meas
EVM 1
Frequency Error
0.0081
TX Power
-2.35879
Amplitude
Traffic Chan
333
-50.0
dBm
Slot
1
Pwr Gain
Auto / Hold
DVCC
20 dB
1
Trig Type
2X Frame

PCS Mode Handset Commands:

1
Enter 575# (Digital signaling mode)
2
11333# (Loads synthesizer Channel)
3
Display prompt " Y" (enter time slot)
4
Display prompt " Y" (enter band, 0 =
800, 1 = 1900)
5
Set power level to step 2 (122#)
6
Turn on transmitt carrier (05#)
The 10 burst average EVM measured should
be less than or equal to 12.5%.
You can also use Digital Call processing to
make these measurements.
52
EVM
kHz
3.9683
dB
Peak EVM
11.6270
Motorola Confidential Proprietary

TX Frequency Error Measurement Test

1
Make sure the Test Set is in Active
%
mode.
2
Select DIG MEAS from the To
%
Screen.
3
Select the DTC Meas field. This
shows the To Screen with a list of
To Scre en
available tests.
CALL CNTL
4
Select EVM 1. EVM 10 can also be
CALL CNFG
selected, it measures a 10 burst aver
ANLG MEAS
SPEC ANL
age.
DIG MEAS
5
Traffic Chan should be set to 333.
6
Put the mobile into test mode.
More
7
EVM is displayed.