Summary of Contents for Logaire Talisman

  • Page 2: Table Of Contents

    THE INSTALLATION AND OPERATING INSTRUCTIONS IN THIS MANUAL APPLY TO LOGAIRE TALISMAN WOODFIRES NOTE: WHILE ALL MODELS HAVE BEEN TESTED TO SHOW COMPLIANCE WITH THE EMISSION LIMITS OF AS/NZS.4013:1999, ONLY SOME MODELS MAY BE INSTALLED IN DISTRICTS HAVING LOWER ALLOWABLE EMISSION LIMITS. PLEASE CHECK WITH YOUR BOROUGH OR SHIRE COUNCIL BEFORE PURCHASING A HEATER.
  • Page 3: Introduction

    Building Authority before commencing installation to find if you will require a Permit and whether there are extra requirements. All LOGAIRE Woodfires have been tested to ensure that they will meet the appropriate safety Standard requirements if the instructions in this book are followed.
  • Page 4: Unpacking

    § Valid only when the room walls are at 90° to each other. ‡ Note: Clearances are for fire hazard only. For durability of finishes or surfaces you should contact the relevant manufacturer for their specification. Logaire accepts no responsibility for the deterioration of surfaces or finishes. AUSTRALIA —...
  • Page 5: Floor Protector (Hearth) Requirements

    Shield Flue Shield Ø Ø Talisman 1265 ¥ Increase by 80 mm if the floor protector top is not at least 50 mm above the floor. ø See page 5 for minimum constructional requirements. Valid only when the fire is exactly at its minimum allowable wall clearance.
  • Page 6: Floor Protector (Hearth) Construction

    Corner Floor Prote ct or Arrangem ent MINIMUM DIMENSIONS — mm See below for construction. Talisman W ith Shelf 1090 Your measurement ‘E’ must be added to ‘X’ and ‘Y’ to find the appropriate minimum overall † floor protector dimensions. See page 3 for minimum values of ‘E’.
  • Page 7: Installing The Flue

    Statewide Heating - Model M 1 with 900mm half-round enamelled flue shield. We recommend the use of genuine Logaire flue kits or kits approved by Logaire. The flue MUST be installed in accordance with the detailed instructions accompanying it. A flue heat shield (including a top dispersal cap), as detailed on page 3, must be fitted at the back of the flue (directly above the stove) to achieve the reduced wall clearances shown in the table.
  • Page 8: Operating Instructions Basic Information

    This control has a sliding action. Pull the knob out to increase the heat output and push it in to decrease the fire. Shutting a high fire down rapidly by starving it of air will result in undesirable emissions. For this reason, Logaire woodfires are designed to settle down to lower heat outputs comparatively slowly. OVERNIGHT BURNING Early stove designs starved the fuel of air to achieve long burn times, creating over-rich fuel/air mixtures and emitting pollutants.
  • Page 9: Operating Hints

    Move the heat output control away from the maximum position only after the fire is well established. A new woodfire should not be run at higher than half setting beyond the first 30 minutes until it has been used for a total of 8 hours. Once fully ‘run in’, we recommend running at full heat for up to one hour after lighting as this will minimise creosote build-up in the flue.
  • Page 10: Safety

    AIR SLIDE If the air slide does not move freely, apply a small amount of heat resistant Logaire air slide lubricant, Part No 794113. CLEANING INSIDE If you wish to clean the flue or clear away creosote debris, the internal components can be removed easily (See below).
  • Page 11 The tube will have one removable angle pin to prevent it from moving endways and falling out. One end of the tube will have a welded-on locating pin. To remove the tube, simply withdraw the angle pin from the tube, move it sideways until one end can be swung down from its locating hole in the firebox side and then move it sideways in the other direction to disengage it completely from the firebox.
  • Page 12: Before Each Heating Season

    To ensure continued safety, check the condition of the following items; the flue system (particularly the flue sections nearest the firebox), the firebox top baffle, the firebox liners and the door gasket. Replace parts only with genuine LOGAIRE spares. Australia Distributor:...