Sunvision Scientific Inc. SV101 IGUANA Active Surveillance System Hardware Installation Manual Version 1.25 Sep. 2006 Revision History Date Version Remark 2006/4 2006/9 1.25 2007/02/27 System requirements and setup...
Sunvision Scientific Inc. 2 System requirements and setup Recommended specifications of computer Intel PD or Core 2 Dual (or above) 1GB or more of DDR (DDR II ) RAM Individual VGA Card AGP x 8 Interface or PCI-E x 16 Interface...
Page 5
Sunvision Scientific Inc. BIOS Setup Note 4: It needs very high system resources to operate the SV101 Iguana recording system. We recommended that you DO NOT install any other unnecessary applications besides the OS and SV101 recording system to avoid...
Sunvision Scientific Inc. 3 SV101 Components When you receive the package of SV101, please open it and check the following items in the package. 1. SV1018 Camera Module 2. SV1018 Camera Module warranty card 3. SV1010 Package A. SV1010 warranty card B.
Page 7
Sunvision Scientific Inc. SV1018Monitor Mounting SV1018 Warranty Card Screw Sets SV1010 Package SV1010 Warranty Card PC Side Connector SV1010 Video Card Watchdog reset cable...
Sunvision Scientific Inc. 3.1.2 Camera module allocation map Upper housing Power supplier Motor control circuit board Terminal board Motor & Mirror module Wild angel camera Telescopic camera IR module Screws 3.1.3 Camera Setup Wild angle camera setup 3.1.3.1 1: BLC (Backlight Compensating function)
Page 10
Sunvision Scientific Inc. The function will be activated when the switch is set on the position of ON. The default is as the above figure shows. Note: The function of 2x two times digital zoom can be used in the applications where the area of interest is narrow and long.
Page 11
Sunvision Scientific Inc. The default value is as the above figure shows. Terminal board 3.1.4 1. RCA Video output terminal 2. Video output switch 3. Video and RS485control input terminal 4. Inside AC output terminal 5. AC power fuse 6. Outside AC input terminal 7.
Page 12
Sunvision Scientific Inc. RCA video output and video output switch 3.1.4.1 A: Wild angle camera output port B: Telescopic camera output port SW1: Wild angle camera output switch SW3: Telescopic camera output switch Note: The video is output to RCA video output terminal when SW1 or SW3 is switched to Normal;The video is output to outside video...
Sunvision Scientific Inc. 2.) AC Power supply cable: (UL) SUT 105℃ VW-1 18AWGx3C is used, round shaped cable Note: The button case of SV1018 camera module uses Lapp, PG-9 cable gland, suitable cable diameter 3.5~8mm 3.2 SV1010 MPEG4 real time hardware compression video card 3.2.1 Introduction to SV1010 MPEG4 video card...
Page 14
Sunvision Scientific Inc. SV1010 MPEG4 video card interface CN3: Video input and RS485 control interface connector definition...
Page 15
Sunvision Scientific Inc. CN2: GPIO control interface connector definition JP1: Watchdog rest connecter...
Page 16
Sunvision Scientific Inc. S1: Card ID &NTSC/PAL setup If the camera module is NTSC video standard, please switch the Pin 4 to OFF. If the camera module is PAL video standard, please witch the Pin 4 to On When installing the first SV1010-MPEG card, switch Pin 1,2,3 to OFF.
Sunvision Scientific Inc. 4.2 SV1010 PC Side Connector Connection There are two ways to connect the SV1010 PC side Connector: One is to use the screwed terminals, the other way is to use the RJ-45 connector. Two connectors can not be used at the same time.
Sunvision Scientific Inc. 4.3 RJ45 connector PIN definition SV1010 PC side connector RJ45 PIN color definition is different than usual network application. Wires need to be arranged as follows to function well. BLUE/WHITE BLUE BROWN/WHITE BROWN Orange/White Orange Green/White Green...
Sunvision Scientific Inc. 5 SV1015 relay I/O control board SV1010 MPEG Video Card can connect with other security equipments by connecting CN2: GPIO interface to SV1015 Relay IO Box Input: TTL voltage Output: maximum current and voltage for each port...
Sunvision Scientific Inc. 6 Camera setup steps Step 1: Mounting and wiring Pass the signal and power supply cables through the head of mounting kit to the bottom, and install the mounting kit at proper location. Step 2: Fasten the screw at the bottom of the mounting kit Please fasten the screw at the bottom of the mounting kit to fix the horizontal and vertical angles of the camera.
Page 23
Sunvision Scientific Inc. Take off the fixed screws around the bottom of the camera, and loosen the ground wire screw of the upper housing to separate the upper and lower housing. Step 4: Setup the camera’s lower housing To pass through the cables (CAT5E cable and power supply cable) from the bottom of the camera and leave about 20~30 cm of cables above the cable glands (Lapp PG-9 cable gland, suitable cable diameter 3.5~8mm).
Page 24
Sunvision Scientific Inc. Outside image and RS485 control Outside AC input terminal 1.) CAT5E cable 2.) Power supply cable Green……CH1 Green/White…GND1 Green Ground Orange……CH2 Orange/White…GND2 Black Neutral Blue……RS485+ Blue/White……RS485- Hot Line Brown……Ground Brown/White…Ground Terminal circuit board connection diagram After wiring is finished,confirm the connection of cable is correct and turn on the power for further test.
Page 25
Sunvision Scientific Inc. to maximum in general applications. For the zoom ratio, you can switch to the output video of the wide angle camera as a reference and switch back to telescopic screen to adjust the required amplification ratio. For example: you can set 3~4x zoom for a convenience store, lobby, or two-lane road;5x or more zoom ratio for a Park, parking garage, or four-lane...
Sunvision Scientific Inc. 7 Camera Module Installation Tips 7.1 Introduction IGUANA Active Surveillance System is a revolutionary surveillance system with high artificial intelligence. The surveillance area covers up to 300M . The method to install the IGUANA is very different from the traditional surveillance cameras. It needs to consider the type of surveillance area, sizes of the intended targets, directions of motion, and the moving speed for the best efficiency.
Page 27
Sunvision Scientific Inc. Wide angle lens cameras can also use the function of 2x digital amplification, to change its angle of view to 53 ゚ X 39 ゚.You can raise the zoom ratio of telescopic lens to 5~8 times or more with this selection. This adjustment is suitable for places which are long and narrow and a higher zoom ratio is preferred.
Sunvision Scientific Inc. *Target size You can set the zoom ratio of the telescopic lens camera to 4 to5 times when the size of the target occupies only 1/6 of the wide angle camera’s screen. You can set the zoom ratio of the telescopic lens camera to 6~10x zoom when the size of...
Page 29
Sunvision Scientific Inc. Park 7.3.2 Station Intended targets: pedestrians Direction of movement: entrance of station, a single moving path Moving speed: 5 Km/hr or less Moving Path Top View of Camera Setup...
Page 30
Sunvision Scientific Inc. Entrance of station 7.3.3 2-lane road Intended targets: mobile license plates Direction of movement: 2-lane road, a single moving path Moving speed: 30 Km/hr Moving Path Top View of Camera Setup...
Page 31
Sunvision Scientific Inc. Two-lane road 7.3.4 4-Lane road Intended targets: mobile license plates Direction of movement: 4-lane road, a single moving path Moving speed: 60 Km/hr Moving Path Top View of Camera Setup...
Page 32
Sunvision Scientific Inc. Four-lane road...