  • Page 1 OPERATION AND INSTALLATION MANUAL Corporate Headquarters 3860 Calle Fortunada San Diego, CA 92123-1825 Phone: (858) 278-2900 FAX: (858) 278-6700 Web-Site: http://www.hardyinst.com Hardy Instruments Document Number: 0596-0191 Rev B-1 Copyright November 1999 Hardy Instruments, Inc. All Rights Reserved. Printed in the U.S.A. (941028)
  • Page 2 ING CASE OR ANY PACKING MATERIAL, UNTIL THE CONTENTS OF THE PACKING CASE ARE INSPECTED AND CAREFULLY COMPARED WITH THE SHIPPING DOCUMENTS. IF ANYTHING IS UNSATISFACTORY, PLEASE NOTIFY HARDY INSTRUMENTS IMMEDIATELY BY CALLING, FAXING OR E-MAILING TO: Customer Support Department HARDY INSTRUMENTS, INC. 3860 Calle Fortunada...
  • Page 3: Table Of Contents

    HIPS SERIES PLATFORM SCALES Table of Contents Table of Contents- - - - - - - - - - - - - - - - - - - - - - - - - - - i Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-1...
  • Page 4: Introduction

    HIPS SERIES PLATFORM SCALES Introduction Congratulations on your purchase of a Hardy Instru- ments HIPS Series platform scale. The Hardy Plat- form Scales are designed for table top or floor applications requiring high accuracy and reliability. The covers are all stainless steel for durability. The bases have no bearings, bubble levels, or moving parts that can be damaged or wear out.
  • Page 5: Preassembly Precautions

    Do not try to remove the load cell or adjust the allen set screws above or below the load cell. Unpacking and The HIPS Series scales are shipped fully assembled Assembly and only require adjustment of the leveling feet. If...
  • Page 6: Leveling The Scale

    HIPS SERIES PLATFORM SCALES Make sure each corner of the upper frame assembly has a rubber boot or strip and that there is a rubber strip in the center for the HI 1212 and Hi 1318 scales. For the HI 1824 and HI 2424, make sure there are rub- ber strips in each corner, down the center and at the center of each 24 inch length of the upper frame.
  • Page 7: C2 Second Generation Calibration

    HIPS SERIES PLATFORM SCALES C2 Second C2 electronically calibrates a scale system without the Generation need for test weights. If you are using a Hardy Instru- Calibration ments HI 2151/20WC, HI 2151/30WC, HI 2160RC controller or HI 1746-WS, Hardy HI 1771-WS weigh module, all that’s required is to enter a reference...
  • Page 8: Mechanical Dimensions

    HIPS SERIES PLATFORM SCALES Loading Point 200% of the rated capacity Temperature Range Safe -30 to +70 Degrees C Compensated -10 to +50 Degrees C Temperature Effect On Output 0.0014% of load/ On Zero 0.003% of rated output/ C 0.006% of...
  • Page 9 HIPS SERIES PLATFORM SCALES Wire Color Signal Gray + C2 Violet - C2 Green + EXC Blue + SENSE + SIG Black - EXC Brown - SENSE White - SIG Inches HI 1212PS HI 1318PS HI 1824PS HI 2424PS (mm)
  • Page 10 HIPS SERIES PLATFORM SCALES Base for HI 1212PS/PSS and HI 1318 PS/PSS With cover removed. Base for HI 1824PS and HI 2424PS with cover removed.
  • Page 11: Capacities

    HIPS SERIES PLATFORM SCALES Capacities HI 1212 HI 1212 HI 1318 HI 1318 HI 1824 HI 2424 (KGS) 10 (4.5) 25 (12.2) 50 (24) 75 (35) 100 (45.3) 125 (60) 150 (68.5) 175 (80) 200 (93) 275 (127) 300 (136) 400 (181.4)
  • Page 12: Model Numbers

    HIPS SERIES PLATFORM SCALES Model Numbers Troubleshooting Scale does not Step 1. Make sure the scale is wired correctly to respond when the instrument and there are no breaks in weight is applied the wiring. Step 2. Lift off the lid and see if there is packing material or debris wedged under the scale.
  • Page 13: Scale Reads Backwards

    Service and Repair For Service and Repairs, contact your local Hardy Representative. Before returning any product to Hardy Instruments Inc., please contact the Customer Support Department for a return authorization number.