Stafford Instruments ST312A User Handbook Manual

Stafford Instruments ST312A User Handbook Manual

Temperature programmer

Advertisement

Notes
Further copies of this handbook may be found at www.staffordinstruments.co.uk/docs/st312a/user312a.pdf
Page
20
ST312A User Handbook
S
D
TAFFOR
User Handbook
ST312A Temperature Programmer
Stafford Instruments Ltd.
www.staffordinstruments.co.uk
Tel: +44(0)1785 255588
email: support@stafford-inst.co.uk
Fax: +44(0)1785 255589
See separate handbook for User Instructions
ST312A User Handbook
© Copyright 2009 Stafford Instruments Ltd.
ST312A
Issue:
2.00
Page 1
Date:
01 June 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST312A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stafford Instruments ST312A

  • Page 1 ST312A Temperature Programmer Stafford Instruments Ltd. www.staffordinstruments.co.uk Tel: +44(0)1785 255588 email: support@stafford-inst.co.uk Fax: +44(0)1785 255589 Further copies of this handbook may be found at www.staffordinstruments.co.uk/docs/st312a/user312a.pdf See separate handbook for User Instructions Issue: 2.00 Page ST312A User Handbook ST312A User Handbook Page 1 ©...
  • Page 2: At A Glance

    Temperature Glaze. Stoneware Glaze is also suitable for Porcelain. DELAYED On Glaze Enamel is also suitable for some enamelling work. START LAMP Heavy Sculpture is also suitable for Terracotta. RAMP 1 LAMP Page ST312A User Handbook ST312A User Handbook Page 19...
  • Page 3: Quick Start Guide

    To change firing data press the & keys to The ST312A can be locked when it is idle (not firing) or while it is firing. It cannot be locked while it is being programmed. change the displayed value If the left-hand decimal point in the dis- °C...
  • Page 4: Table Of Contents

    Firing ............9 SWITCH KILN OFF! Cooling ............13 To reset the ST312A turn off the power to the instrument and have the Adjusting While Firing....... 14 fault investigated by your installer or kiln service engineer to rectify the Error Messages ........... 16 fault.
  • Page 5: Turning On

    Err2 wiring open circuit. Get thermocouple °C/hr and wiring checked. Have thermocouple Next displayed is the thermocouple type to which the ST312A is set. This hr.min replaced if necessary. thermocouple type setting should match the type of thermocouple fitted to the kiln and can be R, S, K or N type.
  • Page 6 This will advance the segment and will immedi- ately terminate a paused soak and end the firing program. Changes made to the operation of the ST312A in this way are temporary The ST312A firing segment comprises 2 ramps followed by a soak period.
  • Page 7 Altering the program Adjusting While Firing When the ST312A is not firing there are no lamps lit on the mimic panel, the run lamp is off and the display shows the kiln temperature with the °C Firing values can be adjusted while the ST312A is firing. Also there are indicator lit.
  • Page 8 Note: to exit programming without cycling through all of the above steps wait 10 To return the ST312A back to idle condition ready for the next firing press seconds without pressing any keys - the ST312A will revert to the idle display.
  • Page 9 Kiln too slow To start a firing press the START/STOP key. The RUN lamp will light. If the ST312A is programmed to heat the kiln at a faster rate than the kiln To stop the firing prematurely press the START/STOP key again.
  • Page 10 Program Record Sheet Ramp 1 Ramp 2 Soak Temp Soak Time Program Description °C/hr °C °C/hr °C hr.min Page ST312A User Handbook ST312A User Handbook Page 11...