  • Page 1 OPERATING MANUAL BLAST CHILLER Page0...
  • Page 2 Device Article number » Type Part number » SF 5P » 07900 SF 5 N » 07901 SF 6P » 07902 SF 6 N » 07903 SF 10P » 07904 SF 10 N » 07905 SF 20P » 07906 SF 20 N »...
  • Page 3: Table Of Contents

    Table of contents Table of contents Page Preface Page Information about gas safety Page Installation Page Control panel Page Engagement of the operations Page Cleaning and maintenance Page Guarantee / assurance Page Notes on safety Page Page2...
  • Page 4: Preface

    Preface The present instruction appertains to the documents delivered with the equipment and contains all necessary information for a correct service and maintenance of the product: protective film do remove (to make of Abb2)and, that the packing material according to the valid rules of the country, in which the product is used, non-polluting is disposed. The user should read then through the contained information attentively and keep the instruction in a slightly accessible place...
  • Page 5: Information About Gas Safety

    Information about the gas safety Danger signalling: Measures with accidental gas escape: - Suffocation - Individual precautions - A fast liquid vaporization can lead to Bringing the personnel into safety rooms. frostbite Anticipating an adequate aeration and Immediate help efforts: employing own protection agents.
  • Page 6: Installation

    Aligning the device with the aid of a spirit level and through the arrangement of the feet with adjustable Installation elevation The installation may only be from specialists under (Pic 6) observation of the legal accident protection definitions of the valid rules of law of the country in which the device is used l at this has the specialists the task, to check possible fire prevention rules.
  • Page 7 • Electric supply manufacturing firm is not liable for possible The equipment must connect onto the mains voltage by thing or person damage, that were caused through means of one error current - safety switch, under an unproper installation. observation of the valid rules of law •...
  • Page 8: Control Panel

    • Operations • Patching panel information START / STOP press button Compressor Led Temperature&timedisplay display Cooling press button Deepfreeze press button Storage press button Alarm Led Time press button Led exhaust wheels Pin probe Led Thawing course Led Programming Led Fig.
  • Page 9 COMPRESSOR LED Announces that the compressor in operation is. A possible flashing START / STOP shows the switch on - wait state at. Switch the chosen cycle at switched off machine FAN ROTOR LED Announces that the exhaust wheels in operation are. A possible COOLING (+70°C +5°C...
  • Page 10: Engagement Of The Operations

    Engagement the following operations through respective keystroke possible: 1. Cooling (+70°C/+3°C) Press button Press button cycle start 2. Deepfreeze (+70°C/-18°C) Press button Press button cycle start 3. Storage (+3°C) Press button Led at Press button cycle start 4. Storage (-18°C) Press button Led at Press button cycle start...
  • Page 11: Cleaning And Maintenance

    Cooling with Time controller Time controller deepfreeze Cooling press button Deepfreeze press button then TIME press then time press button button and START/STOP and START/STOP press. On that press. The calm deep-freezing - time appears to display. For the change of the press button timing On the display appears the calm cool time.
  • Page 12 For the retention of the serviceability of the machine the condenser During the maintenance and cleaning jobs gloves are to use, some is, to keep that is behind the front rust clean To that is for the eyeglasses and a protection mask. elimination of the dirt on the bracings ( \Pic.
  • Page 13: Guarantee / Assurance

    Guarantee / assurance A-5020 Salzburg/Austria Telephone (++43) 0662 880070 Facsimile (++43) 0662 8800708 Company TRADER MACHINE TYPE Blast Chiller Type..MACHINE-NO. ------------------------------------------------- YEAR OF MANUFACTURE ------------------------------------------------- DELIVERY DATE ------------------------------------------------- a) Our customer obliges, to check the product immediately upon delivery and inform us of obvious lacks immediately in writing possible.