BatteryMINDer Plus

VOLTAGE TABLE

MV: Minimum Voltage of a battery the unit will accept.
TV: Trip Voltage to move from Constant Current stage into Float stage.
F: Voltage during the Float stage.
Model
12106
12106A8V
12117
12118

CHARGING / MAINTAINING MULTIPLE BATTERIES

To properly charge or maintain multiple batteries they should all be the same type
(gel, flooded or AGM) and condition. It is OK to mix deep cycle and starter. Charge
each battery individually before connecting together. Never connect batteries at
different states of charge. The charged battery will rapidly transfer energy to the
discharged battery possibly causing catastrophic failure.
Once the batteries are charged, use 18 gauge or greater wire to connect the
batteries.
Parallel Connection Diagram
(12V System using Two 12V Batteries)
Rev. C-011011
Battery Types
6V Lead-Acid
8V Lead-Acid
12V Lead-Acid
12V AGM Specific
(Optima, Odyssey, etc.)
12V
+
12V
+
Models 12106 / 12106A8V / 12117 / 12118
MV
5.5V
7V
10.5V
10.5V
If connecting multiple batteries of the
same voltage, wire them in parallel
(BatteryMINDer positive to positive A to
positive B, BatteryMINDer negative to
negative A to negative B). This is the
same type of connection you would use
when jumping a car (in fact, jumper cables
are great for this).
Page 
TV
F
7.2V
6.7V
9.8V
9V
14.4V
13.4V
14.7V
13.6V
Con't. on next page