Summary of Contents for Joneca Precision-RO
Page 1
P-RO PRECISION RO Ultra-Compact Reverse Osmosis System Installation Guide Owners Manual Joneca Corporation Anaheim Marketing International USA/Canada Sales International Sales 4332 E. La Palma Ave. Anaheim, CA 92807 4332 E. La Palma Ave. Anaheim, CA 92807 tel: 714.993.5997 fax: 714.993.2126 tel: 714.993.1707 fax: 714.993.1930...
Page 2
Precision RO - About The System Congratulations on your purchase of the Precision-RO reverse osmosis system. When properly maintained, this system will provide you with years of trouble-free service. The next sections contain important information on the proper care and maintenance of your system, please take a few minutes to read through this information.
Page 3
Precision RO - Warranty For USA and Canada Only The Limited Warranty extends to the original purchaser of the system. This warranty covers all parts and factory labor needed to repair any Manufacturer-supplied item that proves to be defective in material, workmanship or factory preparation.
Page 5
Precision RO - Non Airgap Faucet Installation Determine the most practical under-the-sink location for placement of the Precision RO system. Ensure that the location allows adequate access for cartridge re- placement. 1. Place the system in the selected location. 2. Place the rubber seal (1) flush against the base of the faucet.
Page 6
Precision RO - Feed & Drain Connections Feed Connection 1. Locate and turn off the angle stop valve on the cold water line feeding the sink where the system is to be installed. This valve will usually be located under the sink Rubber Washer on the pipe coming out of the wall.
Page 7
Precision RO - System Activation & Flushing System Activation and Inspection 1. Check all tubing connections to ensure they are firmly seated. CHECK TO SEE THAT THE CARTRIDGE RETAINER CLIP IS PROPERLY ENGAGED AND LOCKED. Failure to keep the retaining clip in place will result in accidental leaks and flooding.
Page 8
Precision RO - Installation Checklist 1. System is located where it will not be subject to physical impacts or rough contact by heavy objects. 2. Feed water pressure to the unit is no less than 40 psi and no greater than 80 PSI. 3.
Page 9
Precision RO - Cartridge Replacement Cartridge Replacement 1. Close the feed water shut-off valve. 2. Close the tank shut-off valve. 3. Open the dispensing faucet to relieve system pressure. Close dispensing faucet when flow has stopped. 4. Remove the cover from the front of the system. Remove the retaining clip. Pull the cartridge off the system evenly at top and bottom.