Page 2
AMR-OP60/ AMiT, spol. s r.o. does not provide any warranty concerning the contents of this publication and reserves the right to change the documentation without any obligation to inform about it. This document can be copied and redistributed under following conditions: 1.
AMR-OP60/ Contents History of revisions ..................5 Related documentation ................... 5 Introduction ..................6 Technical parameters ................7 2.1. Dimensions ..................... 8 2.2. Recommended drawing symbol ..............9 Conformity assessment ..............10 3.1. Other tests ....................11 Power supply ..................12 RS485 communication line ...............
Page 4
AMR-OP60/ Ordering information and completion ..........47 12.1. Completion ....................47 Maintenance ..................48 Waste disposal ................... 49 amr-op60xx_g_en_100 4/49...
Date Changes 13. 5. 2014 New document Related documentation DetStudio Development Environment Help Data sheet AMR-OP60/xx file: amr-op60xx_d_en_xxx.pdf Application Note AP0016 – Principles of using RS485 interface file: ap0016_en_xx.pdf Application Note AP0025 – ARION Network Communication – definition by table file: ap0025_en_xx.pdf...
Variant 1 – Room mode Variant 2 – Room mode + fan mode Variant 3 – Room mode + bi-stable switch Note: *) Application program is free to download on www.amit.cz. This is a standard application „TA_OP60FW01AM_xxx“. amr-op60xx_g_en_100 6/49...
2 × WAGO 243-204 Connection point Wire cross section 0.6 mm2 to 0.8 mm2 Note: For termination you can use, for example RR 120R from AMiT company production. Mechanics Mechanical design Plastic cover, ABS Mounting Into junction box KU68 with frame *)
Operating temperature range -20 °C to 70 °C Storage temperature range Others Maximum ambient humidity < 95 % non-condensing Application software TA_OP60_FW01AM_xxx Programming DetStudio / EsiDet Communication protocol ARION / MODBUS 2.1. Dimensions Fig. 1 - AMR-OP60/xx dimensions amr-op60xx_g_en_100 8/49...
AMR-OP60/ 2.2. Recommended drawing symbol Following drawing symbol is recommended for AMR-OP60/xx on-wall controller. AMR-OP60/xx PWR, RS485 Fig. 2 - Recommended drawing symbol for AMR-OP60/xx 9/49 amr-op60xx_g_en_100...
AMR-OP60/ 3. Conformity assessment The equipment meets the requirements of NV616/2006 Czech governmental decree. The compliance assessment with NV616/2006 has been performed in accordance with harmonized standard EN 61326-1. Tested in accordance Type of test Classification with standard EN 55011:2009 Industrial, scientific and medical equipment –...
AMR-OP60/ 3.1. Other tests Device was design according to: Tested in accordance Type of test Result with standard Environmental testing – Part 2-1: Test EN 60068-2-1:2007 Complies A: Cold Environmental testing – Part 2-2: Test EN 60068-2-2:2007 Complies B: Dry heat Electromagnetic compatibility (EMC) –...
AMR-OP60/ 4. Power supply AMR-OP60/xx on-wall controller can be powered by DC power sources that meet the requirements, listed in chapter 2. Technical parameters. Fig. 3 - Location of power supply connector Legend Number Meaning Power supply pole Each pole of the connector has 4 connection points. Power supply can be connected to any connection point (see Fig.
Page 13
AMR-OP60/ Wiring AMR-OP60/xx example Ext. power supply PWR, RS485 +24V Fig. 4 - Power supply wiring example Note: It is recommended to connect in one point the GND terminal with switchboard PE terminal when installation is made. 13/49 amr-op60xx_g_en_100...
AMR-OP60/ 5. RS485 communication line Fig. 5 - Location of RS485 Legend Number Meaning Pole RS485 Each pole of the connector has 4 connection points. RS485 can be connected to any connection point (see Fig. 9 - Connecting to connection points).
Page 15
AMR-OP60 Fig. 7 - Connecting structured cabling to poles of controller RS485 line In case AMR-OP60/xx is an end-station on RS485 line, the line must be terminated with external terminating resistor 120 Ω, connected between poles A termination and B (for example RR 120R from AMiT company production.)
Page 16
AMR-OP60/ Fig. 8 - RS485 line termination Legend Number Meaning External terminating resistor Any connection point of each pole of RS485 line can be used for connection of external resistor. (see following figure) Fig. 9 - Connecting to connection points (poles detail in plan view)
Page 17
AMR-OP60/ Legend Number Meaning RS485 connection Connection of terminating resistor Activity Activity on RS485 line is indicated on LCD. If it is not specified other way in indication control system (via Guard Time), icon is displayed 30 s after communication...
AMR-OP60/ 6. Mounting Should be placed in the interior, in dry environment, about 1.5 m above the floor, in area with good air circulation. Controller should not be placed in area where its temperature can be affected by the wind, sunshine, heat radiation from the heater, or other factors.
AMR-OP60/ 6.1. Dismounting on-wall controller electronics Electronics of on-wall controller can be released from the frame by gentle pressure on the latches located on both sides of electronics (for example with a screwdriver). After that it is possible to eject it from the frame.
AMR-OP60/ 7. Setup and operation of on-wall controller On-wall controller has several working screens. Basic displayed all time. User menu displayed after a short press on the button under the menu icon. Configuration menu displayed after a long press on the button under the menu icon.
Page 21
AMR-OP60/ Date and time is received from superior control system. The time will not be displayed if the time information is not sent by the superior control system after power supply connection or restart. Measured temperature Fig. 14 - Measured temperature Room temperature is displayed on LCD independently of communication.
Page 22
AMR-OP60/ Fig. 16 - Correction of required temperature Correction value is changed to plus or minus by pressing buttons under icons. After each correction change, instead of requested temperature, hyphens are displayed, until new requested temperature value is received from the superior control system.
AMR-OP60/ 7.2. Mode icons Mode icons depend on application. 7.2.1 Variant 1 Fig. 18 - Icon for mode variant 1 Legend Number Meaning Icon showing what room mode is set By pressing button under icon you can switch between three room modes.
AMR-OP60/ 7.2.2 Variant 2 Fig. 19 - Icon for mode variant 2 Legend Number Meaning Icon showing what room mode is set Icon showing what fan mode is set Icon, showing function for calling screen for setting correction By pressing button under icon 1 you can switch between three room modes.
AMR-OP60/ 7.2.3 Variant 3 Fig. 20 - Icon for mode variant 3 Legend Number Meaning Icon showing what room mode is set Icon showing switch status Icon, showing function for calling screen for setting correction By pressing button under icon 1 you can switch between three room modes.
AMR-OP60/ 7.3. User’s menu User menu can be called by pressing button under icon Fig. 21 - Calling user menu Legend Number Meaning Icon above the button for calling user menu Menu items. Fig. 22 - User’s menu Legend Number Meaning Menu items.
Page 27
AMR-OP60/ Meaning of buttons under icons (2) is as follows: Icon Meaning Leaving the screen Go to next item Go to previous item Confirmation of selected menu item Next items can be selected from the menu: Brightness Contrast ...
Page 28
AMR-OP60/ Contrast The display contrast can be set, by item Contrast. Fig. 24 - Contrast setting Legend Number Meaning Set contrast level Icons signalizing about possibility to raise / lower contrast level Meaning of buttons under icons (2) is as follows:...
Page 29
AMR-OP60/ Display Item Display allows setting screen saver time delay. Fig. 26 - Setting time for screen saver activation Legend Number Meaning Time after which screen saver is activated Icons signalizing about possibility to change time. Meaning of buttons under icons (2) is as follows:...
AMR-OP60/ 7.4. Configuration menu Configuration menu can be called-out by a long press on button under icon for at least 10 s. Fig. 28 - Calling configuration menu Legend Number Meaning Icon above the button for calling configuration menu Caution: Setting of on-wall controller (software and hardware) should be performed strictly by service company.
Page 31
AMR-OP60/xx communication parameters can be set via Connection item. Closer information can be found in chapter 7.4.1. Communication settings. FW setting Via item FW setting, the one of three variants of AMR-OP60/xx can be selected (see chapter 7.2. Mode icons). Fig. 30 - Variant selection...
AMR-OP60/ Fig. 31 - Correction of temperature sensor Legend Number Meaning Set correction value Icons above the buttons for working with screen Meaning of buttons under icons (2) is as follows: Icon Meaning Leaving the screen Reduce correction value Increase correction value Confirmation of correction value Sensor correction value can be set within the range -1.5 °C to 1.5 °C...
Page 33
AMR-OP60/ Meaning of buttons under icons (2) is as follows: Icon Meaning Leaving the screen Go to next item Go to previous item Confirmation of selected menu item Next items can be selected from the menu: Net type Address ...
Page 34
AMR-OP60/ Fig. 34 - Setting address Legend Number Meaning Address Icons above the buttons for working with screen Meaning of buttons under icons (2) is as follows: Icon Meaning Leaving the screen Reduce address value Increase address value Confirmation of selected variant...
Page 35
AMR-OP60/ Meaning of buttons under icons (2) is as follows: Icon Meaning Leaving the screen Go to next value Go to previous value Confirmation of selected speed Parity There is a point to set this item only if the MODBUS protocol was selected.
AMR-OP60/ 7.5. Screen saver If allowed in menu, screen saver is displayed after pre-set time (screen saver is displayed, backlight is off) After first press of any key- backlight is turned on, after second press- basic screen is displayed. Fig. 38 - Screen for screen saver...
Page 37
AMR-OP60/ Fig. 40 - Communication interruption during active screen saver Icon is displayed until controller receives valid data from the superior control system. 37/49 amr-op60xx_g_en_100...
AMR-OP60/ 8. ARION protocol program operation In ARION network, the AMR-OP60/xx controller provides data via registers in combination with digital input/output channels. 8.1. Digital inputs On-wall controller status information is transferred via digital inputs. Description of Function Number of Note:...
AMR-OP60/ Status set R/W Setting corresponding bits of Status registry. The bit is set in case of simultaneous writing of (Bit 16 to 32) value True to the setting and zeroing registers (prevailing "set"). While reading this registry, the last recorded value is returned.
AMR-OP60/ 8.5. Communication interruption On-wall controller supports communication interruption control (parameter Guard Time in ARION network) In case the communication interruption has occurred, the icon is displayed on the on-wall controller (see chapter 7.6. Communication interruption). Bits 0 to 7 of the Status registry are set to value True.
AMR-OP60/ 9. MODBUS protocol program operation AMR-OP60/xx provides data via holding registers in MODBUS network. Note: Communication with one stop bit takes place, if there is an odd or even parity set. Communication with two stop bits takes place, when no parity is set.
Page 42
LED brightness[%]. Range: 0 to 100. Value 0 brightness corresponds with minimal brightness, but not LED (Float) power off. Note: *) Is not active in AMR-OP60/xx. Possible writing value to the registry is ignored and does not affect the function of the on-wall controller. amr-op60xx_g_en_100 42/49...
AMR-OP60/ 9.2. Operating time setting Writing time to the single on-wall controller, connected to the MODBUS network is performed by writing to the registers 2 and 3 of the particular on-wall controller. 9.3. Communication interruption On-wall controller supports communication interruption control. If the on-wall...
“Service menu”. Service application in AMR-OP60/xx is always available, user can always switch to it, and it cannot be deleted. Service application can be accessed by holding all four AMR-OP60/xx buttons pressed for at least 3 seconds. amr-op60xx_g_en_100 44/49...
AMR-OP60/ 10.3. Service menu After switching to service application, the service menu is displayed. Fig. 41 - Items of service menu Following items can be set via service menu: Brightness- brightness intensity change Contrast – change of display contrast ...
AMR-OP60/ 11. Factory settings RS 485 Without external terminating resistor. configuration Program Item Set value settings Network type ARION Address Baud rate 38400 bps Viewing variant Variant 1 0.0 °C Correction Display Set value Brightness 100 % Contrast 50 %...
AMR-OP60/ 12. Ordering information and completion On-wall AMR-OP60/xx *) Complete, see chapter 12.1. Completion controller Note: *) xx indicates colour design of the product. Available versions are listed in datasheet. Others RR 120R External termination resistor for RS485 12.1. Completion...
AMR-OP60/ 13. Maintenance Device requires no periodic control. Covers should be cleaned with soft cloth. Dirty covers should be washed with gently wet cloth with mild soap solution, and then wiped with dry cloth. Never use tough cleaning cloth, or preparations containing sharp parts to clean covers of the controller.
AMR-OP60/ 14. Waste disposal Electronics The disposal of electronic equipment is subject to the regulations on handling disposal electrical waste. The equipment must not be disposed of in common public waste. It must be delivered to places specified for that purpose and recycled.