Aqua PRO GPH550PRO Operating Instructions And Replacement Parts List Manual

Aquapro systems gas powered water pump user manual
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Operating Instructions and Replacement Parts List
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
The Aqua Pro pumps are general use
centrifugal water pumps.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
1. Know the pump application,
limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.
DANGER
!
Never run engine in an
enclosed area. Exhaust gases
contain deadly poisonous carbon
monoxide, which has no odor or taste.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
Gas Powered
Water Pump
WARNING
!
Do not use to pump flammable
or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not
use in flammable and/or explosive
atmospheres. Pump should only be used
with liquids compatible with pump
component materials. Failure to follow
this warning can result in personal injury
and/or property damage.
2. Observe all safety precautions for the
handling of the fuel.
WARNING
!
Do not refuel a hot engine.
Fuel spilled on a hot engine
could result in a fire or explosion. Do not
refuel a running engine.
3. Pump should be located and should
rest on a level solid foundation. Do
not suspend pump by means of the
discharge pipe.
Be sure pump is on
NOTICE
secure footing so it
doesn't fall over.
4. Do not use torches or apply excessive
heat, fire or flames to this pump as an
explosion may result.
5. Before working on the unit, insulate
the wire from the spark plug,
disconnect the spark plug wire and
mount it on the grounding clip.
Complete pump
NOTICE
and piping system
MUST be protected against below
freezing temperature. Failure to do so
could cause serious damage and voids
the warranty.
6. Do not run pump dry. Water is
required to lubricate the shaft
seal.
7. Pumping chemicals or corrosive
liquids with this pump may shorten
GPH550PRO
Need
Assistance?
Call Us First!
1-877-278-2797
the life of the pump and may be
hazardous to the operator.
8. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors at a safe distance from
the work area.
d. Make workshop child-proof with
padlocks, master switches, and by
removing starter keys.
9. Always use a suction strainer with this
pump to filter large material.
Installation
This pump is designed to be self-
priming when installed and operated as
specified below.
1. The pump should be placed as close
as possible to the liquid being
pumped. A pump with 20 foot
suction lift will not remove water as
quickly as a pump with 5 foot
suction lift (Figure 1).
20 Ft.
Suction Lift
5 Ft.
Suction
Lift
Figure 1
2. Suction hose and fitting must be
airtight.
322600-013 03/06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GPH550PRO and is the answer not in the manual?

Questions and answers

Summary of Contents for Aqua PRO GPH550PRO

  • Page 1 6. Do not run pump dry. Water is required to lubricate the shaft seal. 7. Pumping chemicals or corrosive liquids with this pump may shorten GPH550PRO Need Assistance? Call Us First! 1-877-278-2797 the life of the pump and may be hazardous to the operator.
  • Page 2: Maintenance

    Operating Instructions and Replacement Parts List Installation (Continued) An air leak in the NOTICE suction line may prevent priming of the pump. Use of thread sealant is recommended. Suction lines must be reinforced hose or rigid pipe. Non-reinforced hose will collapse due to the suction created by the pump and prevent pump from operating.
  • Page 3 Operating Instructions and Replacement Parts List Performance Information Model Discharge Head GPH550PRO Gallons/Hour Pipe Size 20000 15000 10000 5000 Semi-Trash Pump Performance GAS PERFORMANCE 16800 FEET FRICTION LOSS IN 100 FEET OF PLASTIC PIPE Gallons Per Minute 11.9 20.2 30.5 14.3...
  • Page 4: Suction Hose

    Hose coupled both ends with 2" hose thread. One 20 ft. hose per carton Address parts correspondence to: Aqua Pro Systems 101 Production Drive Harrison, OH 45030 5.5 HP HONDA OHV GPH550PRO LAY FLAT DISCHARGE HOSE PART #16511 • Economical •...
  • Page 5 Item Part Description Honda Engine Shaft Seal Kit Suction Flange Flapper Check Valve Discharge Flange Kit Drain/Fill Plug Impeller Address parts correspondence to: Aqua Pro Systems 101 Production Drive Harrison, OH 45030 GPH550PRO 57812-001 66047-WYN1 42007-001 37306-001 66049-WYN1 28444-001 41020-001...
  • Page 6 Operating Instructions and Replacement Parts List Limited Warranty For one year from date of purchase, Aqua Pro (”Wayne Water Systems“) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (”Product“) found upon examination by Aqua Pro to be defective in materials or workmanship.
  • Page 7 5. Antes de efectuar trabajos en la unidad, aísle el cable de la bujía, desconecte el cable de la bujía y conéctelo al sujetador de conexión a tierra. Adjúntela a este manual o archívela en lugar seguro. GPH550PRO ¿Usted necesitan ayunda? ¡Llámenos Primero!
  • Page 8: Instalación

    Instrucciones de Funcionamiento y Lista de Piezas de Repuesto Instalación (Continuación) Altura de Succión de 20 pies (6 m) Altura de Succión de 5 pies (1,5 m) Figura 1 AVISO Una pérdida de aire en la línea de succión puede impedir el cebado de la bomba.
  • Page 9 Instrucciones de Funcionamiento y Lista de Piezas de Repuesto Características de Rendimiento Modelo Altura de descarga GPH550PRO Galones/Hora PÉRDIDA DE ALTURA POR FRICCIÓN EN 100 PIES (30 m) DE TUBERÍA DE PLÁSTICO Diá. de la Tubería 20000 15000 10000 5000...
  • Page 10 2" en ambos extremos. Una manguera de 20 pies (6 m) por caja Dirija su correspondencia sobre repuestos a: Aqua Pro Systems 101 Production Drive Harrison, OH 45030 U.S.A. 5.5 HP HONDA OHV GPH550PRO MANGUERA EN LONA PARA DESCARGA REPUESTO #16511 • Económica •...
  • Page 11 Válvula de contención de charnela Juego de Reborde de Descarga Tapón de drenaje/llenado Impulsor Dirija su correspondencia sobre repuestos a: Aqua Pro Systems 101 Production Drive Harrison, OH 45030 U.S.A. GPH550PRO Cant. 57812-001 66047-WYN1 42007-001 37306-001 66049-WYN1 28444-001 5 SP...
  • Page 12: Garantía Limitada

    Instrucciones de Funcionamiento y Lista de Piezas de Repuesto Garantía Limitada Durante un (1) año a partir de la fecha de compra, Aqua Pro (“Wayne Water Systems”) reparará o reemplazará, según lo decida, para el comprador original, cualquier pieza o piezas de sus Bombas para cloacas o Bombas de agua (el “Producto”) que después de un examen sea(n) hallada(s) por Aqua Pro como defectuosa(s) en su material o mano de obra.

Table of Contents

Save PDF