Description Of Schematic Diagram - Sharp 27R-FS1 Service Manual

Chassis no.v01a
Hide thumbs Also See for 27R-FS1:
Table of Contents

Advertisement

27R-FS1

DESCRIPTION OF SCHEMATIC DIAGRAM

NOTES:
1. The unit of resistance "ohm" is omitted.
(K=k Ω =1000 Ω , M=M Ω )
2. All resistors are 1/16 watt, unless otherwise noted.
3. All capacitors are µ F, unless otherwise noted.
(P=pF=µµF)
4. (G) indicates ±2% tolerance may be used.
5.
indicates line isolated ground.
VOLTAGE MEASUREMENT CONDITIONS:
1. All DC voltages are measured with DVM connected
between points indicated and chassis ground, line
voltage set at 120V AC and all controls set for normal
picture unless otherwise indicated.
2. All voltages measured with 1000µ V B & W or Color
signal.
1
2
130Vp-p
Horiz Rate
6
7
240Vp-p
77KHz
q
w
1.5Vp-p
Horiz Rate
WAVEFORMS
3
125Vp-p
145Vp-p
Horiz Rate
Horiz Rate
8
180Vp-p
0.8Vp-p
Horiz Rate
Horiz Rate
e
50Vp-p
1.4Vp-p
Vert Rate
Horiz Rate
WAVEFORM MEASUREMENT CONDITIONS:
1. Photographs taken on a standard gated color bar
signal, the tint setting adjusted for proper color. The
wave shapes at the red, green and blue cathodes of
the picture tube depend on the tint, color level and
picture control.
2.
indicates waveform check points (See chart,
waveforms are measured from point indicated to
chassis ground.)
å
AND SHADED (
= SAFETY RELATED PARTS.
' MARK= X-RAY RELATED PARTS.
This circuit diagram is a standard one, printed circuits
may be subject to change for product improvement
without prior notice.
4
12Vp-p
77KHz
9
1170Vp-p
Horiz Rate
r
9Vp-p
Horiz Rate
16
) COMPONENTS
5
400Vp-p
77KHz
0
2Vp-p
Vert Rate

Advertisement

Table of Contents
loading

Table of Contents