Occupancy Sensor - Wall Mounted
2.5"
64mm
Solar Cell
Lens
Button
Interface
Package Contents
▪
Occupancy Sensor
▪
2 screws, 2 wall anchors
▪
1 wide angle lens
(installed)
▪
1 long range lens
Product Description
The wall-mounted Occupancy Sensor saves energy and adds
convenience by accurately detecting when an area is occupied
or vacant.
It is wireless, solar-powered, and uses a passive infrared (PIR)
sensor to detect motion. The occupancy sensor transmits RF
signals to control lighting, HVAC and outlets more efficiently.
Features Include:
▪
Sends wireless signals to receiving devices when
motion is detected
▪
Harvests indoor light to power the sensor and wireless
communications
▪
Mounts flush on the wall or in a corner - adjustable ceiling
and wall brackets also available
▪
Works with other sensors for enhanced occupancy tracking
▪
Interchangeable lenses for tailored sensor coverage
▪
Built-in tests to confirm operation at installed location
▪
Supplemental battery or alternative power supply options for
extreme low-light conditions
© 2014 EnOcean GmbH
1.1"
28mm
5.8"
148mm
1.8"
45.7mm
Tools Required
▪
Power drill, 3/16" bit
▪
Screwdriver
▪
Leveling tool
▪
Light meter
▪
Battery (CR2032) for testing
Specifications (typ. values)
Power Supply:
Optional:
RF Transmission Range
Motion Sensing Range
Startup Charge Times*
First motion
transmission / Linking
Motion LED blink
Light/Walk Test Modes
Sustaining Charge Time
for battery free operation
Time to Full Charge*
Operating Life in
Total Darkness
Minimum Operating Light
Optional Battery Life:
• Infrequent Bright Light
• Consistent Low Light
• Total Darkness
Motion Transmission Interval
Unoccupied Transmission
Heartbeat Transmission
Interval (unoccupied)
EnOcean Equipment Profile
RF Communications
Dimensions
Weight
Mounting Height
Environment
Agency Compliance
* Natural bright light (2000 lux) or a battery can be temporarily used to
significantly shorten startup charge times. Specified lux values are for typical
fluorescent lighting. Lux level requirements for LED and other types may vary.
For lux reference, OSHA standards require a minimum of 323 lux for office
areas.
Installation Guide
Model: EOSW
Indoor light energy harvesting
Supplemental battery (CR2032)
2-wire connector for external power
or remote solar cell (3-5 VDC)
80 ft. (25 m)
Up to 100 ft. (30 m)
(refer to coverage diagrams)
(operation from empty energy storage)
5 minutes @ 200 lux
1.5 hours @ 2000 lux
3 hours per 24 hours @ 200 lux
25 hours @ 200 lux
80 hours
(after full charge)
50 lux (for auto-off only)
20 yrs
(with 200 lux for 2 hrs/day, 7 days/week)
15 yrs
(with 65 lux for 5 hrs/day, 7 days/week)
6.5 yrs
2 minutes
10 and 30 minutes since last motion
Disabled by default
Enabled = heartbeat @ 1 hr interval
(after unnocupied messages)
A5-07-01 (EEP)
EnOcean 902 MHz (EOSWU)
EnOcean 868 MHz (EOSWA)
EnOcean 315 MHz (EOSWC)
EnOcean 928 MHz (EOSWJ)
5.83" L x 2.52" W x 1.8" D
(148 mm x 64 mm x 45.7 mm)
4.09 oz. (116 g)
6-8 feet (1.8 - 2.5m) recommended
Indoor use only
14° to 104°F (-10° to 40°C)
20% to 95% relative humidity
(non-condensing)
FCC, IC, RoHS, CE, R&TTE
Page 1
Need help?
Do you have a question about the EOSW and is the answer not in the manual?
Questions and answers