Do you have a question about the ADVANTAGE DKS II 24-1000D and is the answer not in the manual?
Questions and answers
Summary of Contents for American access system ADVANTAGE DKS II 24-1000D
Page 1
User/Installation Manual ADVANTAGE DKS II with Advantage RCG Technology MODEL 24-1000D trol” “Your Partner in Access Con www.americanaccess.com...
Page 2
AAS 2Year Limited Warranty What item(s) this warranty applies to: American Access Systems “ADVANTAGE DKS II (24-XXXX series)” access controls. What is covered: Any defect in materials or workmanship. For how long: Two years from date of purchase. What we will do: If your AAS product is defective and returned within 2 years of the date of purchase, we will repair it or, at our option, replace it at no charge to you.
PARTS CHECKLIST Enclosed with this box you should have the following items. Description Desk Station Wall Plug In Transformer If any of the above items are missing from this box, contact American Access Systems Tools Needed For Basic Installation • • Wire strippers •...
BEFORE PROCEEDING To take full advantage of the 24 month limited warranty, you must be registered with American Access SystemsS. Please read the enclosed warranty statement, (pg 2), fill out the warranty registration card provided and send it to: 1675 West Yale Ave. Englewood, CO 80110 phone: 303-799-9757 fax: 303-799-9756...
Page 5
STEP 2-SYSTEM CONNECTIONS HOOKUP STEPS ACCESS CONTROL UNIT (ACU) STEP 2 -SYSTEM CONNECTIONS HOOKUP STEPS CONTROL RELAYS COMMUNICATIONS & RELAYS PRINTER POWER HOOKUP (A). Make all your prox slave connections BEFORE you apply power to the master unit. To connect power to your new desk unit plug the wall tranformer into an outlet and insert the other end in the back of the unit.
Page 6
USING A SLAVE WITH THE ADVANTAGE DKS II WIRE RECOMMENDATIONS: 6 CONDUCTOR, 22 GUAGE, TWISTED SHIELDED CABLE The ADVANTAGE DKS II communicates with two 12-000 slave keypads utilizing wiegand technology. NOTE: Do not run your gate control wires in the same shielded cable as your slave communication wires. There are two holes on the back of the unit which are for slave communication wires, and gate control wires.
FUNCTION CODES FUNCTION CODE DESCRIPTION “Master Code” This is a 5 digit programmable code between 00000 and 65535 used for gaining access to the program mode. The factory default is “0 1 2 5 1”. “Relay A Latch Card” This is a user programmable card(s) used to lock down (or unlock) relay A.
MASTER RESET Follow these steps precisely. If you make an entry error, the unit will ERROR and you will have to start over. (1). Disconnect power from the master board (2). Reconnect power to the board while holding down the RESET BUTTON (3).
Page 9
PROGRAMMING A person desiring access to the program mode will enter the present MASTER CODE. If the master code is valid the yellow LED will come on and the individual will be prompted with a QUICKBEEP to enter a 3 digit number corresponding to a SUBMODE.
Page 10
GROUP 100 (PROGRAMMING CODES) “100” SUBMODE 100 (PROGRAM ACCESS CODES) HELPFUL HINT: REMEMBER, IF YOU DO NOT WANT TO COME UP WITH CODES YOURSELF THIS UNIT CONTAINS AN RCG FEATURE (RANDOM CODE GENERATION) SEE SUBMODE 304 AND 305. KEEP IN MIND YOUR NEW CODES MUST BE LESS THAN 65535 AND NOT ALREADY IN USE BY THE SYSTEM.
Page 11
“103” SUBMODE 103 (PROGRAM SLEEP CODE) DESCRIPTION: The SLEEP MODE is the mode of operation in which the unit shuts down and goes to sleep. Only MANAGERS CODES are accepted into the system in this mode. The SLEEP CODE is accepted into the system from the master unit or either slave.
Page 12
GROUP 200 (DELETING CODES) “200” SubMode 200 (DELETE CODES) To delete any code from memory, with the exception of the MASTER CODE, enter the 5 digit “MASTER CODE” followed by submode “200” and then the code to be deleted. (MASTER CODE) + 200 + (CODE TO BE DELETED) + (NEXT CODE TO BE DELETED) etc...(# to exit) You may continue deleting codes in a successive manner.
Page 13
“303” SubMode 303 (SET CLOCK DATE) DESCRIPTION: The ADVANTAGE DKS II unit incorporates an on board 365 day a year calendar and also adjusts for LEAP YEAR. Years can be entered up to 2025. To set the clock date enter the 5 digit “MASTER CODE” followed by submode “303” then the “MONTH” and “DAY” and “YEAR”.
Page 14
“306” SubMode 306 (TOGGLE 3 STRIKES ON/OFF) NOTE: From the factory, 3 strikes is disabled. DESCRIPTION: This feature is desirable to keep unwanted persons from successively entering codes until they “hit” a programmed access code. By selecting this function you enable a 1 1/2 minute lock out time if 3 incorrect codes are entered successively within a 3 minute period.
Page 15
“309” SubMode 309 (QUIET MODE) NOTE: From the factory, QUIET MODE is enabled. DESCRIPTION: If you want to hear the good or bad beeps at your desk when an access code is entered at the slave keypad you can disable the quiet mode. This sub-mode can be toggled on or off by pressing: (MASTER CODE) + 309(*) + (MASTER CODE) (*) 1 BEEP AND RED LED ON = FEATURE ENABLED (*) 2 BEEP AND RED LED OFF = FEATURE DISABLED...
Page 16
“404” SubMode 404 (RED PRINTING ON INVALID CODES) This option is only available if you are using an AAS OM-200 printer. The option will print out every invalid code in red. This feature is disabled by default. To toggle this feature on or off press: (MASTER CODE) + 404(*) + (MASTER CODE) (*) 1 BEEP AND RED LED ON = FEATURE ENABLED (*) 2 BEEP AND RED LED OFF = FEATURE DISABLED...
Page 17
Access Name Page 17 American Access Systems / Security Brands, Inc.
MASTER BOARD RESET CONNECTION FOR 12 VOLT BULB BUTTON CONNECTOR FOR COMMUNICATIONS AND RELAYS BOARD PRINTER POWER TRANSFORMER PLUG-IN SEE PAGE 6 WIEGAND COLOR CODES FOR SLAVE INTERFACE COMMUNICATIONS AND RELAYS BOARD Page 18 American Access Systems / Security Brands, Inc.
CUSTOMER SERVICE AND TECH SUPPORT Customer Service: 303-799-9757 Customer service is available free of charge. Hours are 8:00 a.m. to 4:30 p.m. MST. If you call, please have your Model and Serial Number to help our Technicians assist you. E-Mail: customerservice@securitybrandsinc.com Technical Support: 303-799-9757 Technical support is available free of charge.
Page 20
“YOUR PARTNER IN ACCESS CONTROL” WWW.SECURITYBRANDSINC.COM SECURITY BRANDS...
Need help?
Do you have a question about the ADVANTAGE DKS II 24-1000D and is the answer not in the manual?